AS-i/PROFIBUS Gateway

 




AS-i/PROFIBUS DP Gateway/Link


1 AS-i Master
PROFIBUS Slave

with AS-i Scope

AS-i Specification 2.1








Graphical Display
Art. no. BW1307
  Art. no. BW1249
Operating current

Master power supply A
Approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
PROFIBUS Interface
According to DIN 19245 part 3
Baud rates
9,6 KBaud up to 12000 KBaud, automatic recognition
DP functions
Imaging of the AS-i slaves as I/O Data of the PROFIBUS.
Complete diagnosis and configuration via the PROFIBUS DP
AS-i cycle time
150 µs*(Number of slaves + 1)
Displays

LCD
Displaying slave addresses and error messages
LED green (power)
Power on
LED green (ser active)
Communication and control information
LED red (config error)
Configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
Automatic address programming enabled
LED yellow (prj mode)
The Master is in configuration mode
Push-buttons
2 (mode/set), devices with graphical display: 4
Voltage of insulation
> 500 V
EMC directions
EN 50082, EN 50081
Operating temperature
   0°C ... +55°C
Storage temperature
-25°C ... +85°C
Housing
Housing for DIN-rail mounting
Dimensions (L, W, H)
75 mm, 100 mm, 110 mm
Protection category
(DIN 40 050)
Housing IP40
Terminals IP20
Tolerable loading reffering to impacts and vibrations
Screw-mounting: b < 30 g, T < 11 ms
Spring lock-mounting: b < 15 g, T < 11 ms
Screw-mounting: f < 55 Hz, a < 1 mm
Spring lock-mounting: f < 55 Hz, a £ 0,5 mm
Weight
420 g



AS-i/PROFIBUS DP Gateway/Link

2 AS-i Masters

AS-i Specification 2.1

AS-i Scope




 

Graphical Display
Art. no. BW1309
Operating current

Master power supply A
with plug connectors:
Approx. 200 mA out of AS-i circuit 1
Approx. 70 mA out of AS-i circuit 2
without plug connectors
Approx. 150 mA out of power supply
Approx. 70 mA out of AS-i circuit 1
Approx. 70 mA out of AS-i circuit 2
Operating voltage
24 V DC (18-31,6 V DC)
PROFIBUS interface
According to DIN 19245 part 1-3
Baud rates
9,6 KBaud up to 12000 KBaud, automatic recognition
DP-Functions
Imaging of the AS-i slaves as I/O Data of the PROFIBUS.
Complete diagnosis and configuration via the PROFIBUS DP
AS-i cycle time
150 µs*(Number of slaves + 1)
Displays

LCD
Displaying slave addresses and error messages
LED green (AS-i 2)
AS-i network 1 / AS-i network 2
LED green (ser active)
Communication and control information
LED red (config error)
Configuration error
LED green (power)
Power on
LED green (U AS-i)
AS-i voltage OK
LED green (prg enable)
Automatic address programming enabled
LED yellow (prj mode)
The Master is in configuration mode
Push-buttons
4
Voltage of insulation
> 500 V
EMC directions
EN 50082, EN 50081
Operating temperature
   0°C ... +55°C
Storage temperature
-25°C ... +85°C
Housing
Housing for DIN-rail mounting
Dimensions (L, W, H)
75 mm, 100 mm, 110 mm
Protection category DIN 40 050
Housing IP40
Terminals IP20
Weight
420 g


Accessories:
Software "AS-i Control Tools" (Article no. BW1203)
Serial PROFIBUS Master (Article no. BW1258)
PROFIBUS DP Mastersimulator DP V0 and DP V1 (Article no. BW1257)
Transmission cords (Article no. BW1097)


Search keys: BWU1307, BWU1249, BWU1309, BW1307, BW1249, BW1309, 1307, 1249, 1309

See also:



Bihl+Wiedemann GmbH
Floßwörthstr. 41
D-68199 Mannheim
Phone: (+49) 621 / 339 96-0
Fax: (+49) 621 / 339 22 39
eMail: mail@bihl-wiedemann.de
Internet: http://www.bihl-wiedemann.de