7

AS-i Signal Measuring Adapter

 

 

See also:

 

 

 

 

 

 

AS-i Signal Measuring Adapter
 
Output of the AS-i I/O via
digital and analog outputs

 

Ideally in combination with standard measuring sensors

 

Running time measurements

 

Suppling debugging within Mini-PLC programms

 

Additionally all functions of the AS-i Analyser included

 

 

 

 

 

 

Article no. BW1559

The AS-i signal measuring adapter allows the uptodate output of
In- and output signals transferred via AS-i. For this the signal measuring adapter is connected to AS-i as passiv member. With the help of the AS-i signal measuring adapter the AS-i in- and outputs can defined per PC software, which present condition will be set up to the digital and analog output of the signal measuring adapter. Errors in the chronological order of the mini-PLC program or running time measurements as well reaction times can be easilly investigated.

Additionally all functions of the AS-i Analyser are included.

The easy to use diagnosis software provides each AS-i slave immediately with an overview of the qualitity of the AS-i installation with the help of a traffic light (red, green, yellow). The user must be not an AS-i specialist to judge the qualitity of a AS-i network or to detect errors. An easy statistic mode shows all faulty data telegrams of all connected slaves in case of problems. After a test run a testing protocol with all sampled statistic data can be printed with the help of the AS-i signal measuring adapter.

Furthermore the AS-i signal measuring offers also for an AS-i specialist the possibility to find and to solve the most difficult errors with extensive triggers (3 levels of triggers, extern trigger input, trigger output and so on) and filter functions.

 

Article no.

BW1559

 

Requirements:

IBM compatible PC 80486 or higher

 

Operating system:

Windows 98, Windows Me, Windows 2000, Windows XP and Windows NT4

 

Specification:

  • Software:
    AS-i Signal Measuring Adapter
  • Hardware:
    AS-i Signal Measuring Adapter
    D-sub data transmission cord
  • 24 V power supply for external supply

 

Accessories

AS-i Tuner (art. no.BWU1648)

Type

Passive AS-i member

Outputs (analog)

2 analog outputs on D-sub socket 9 pins,
output voltage 0 - 10 V

Outputs (digital)

16 digital outputs on D-sub socket 25 pin,
output voltage 0/24 V

Interfaces

- AS-i
- RS 232 for connection to a PC
- Trigger input (24 V)
- Trigger output (TTL), BNC socket
- External voltage supply 24 V
- Analog outputs to measuring sensor
- Digital outputs to measuring sensor

Displays

LED green (Power)

Power on

LED yellow (ser active)

RS 232 interface in operation

LED green/red (Test)

Test mode

Telegram memory

256.000 AS-i telegrams

Operating current

- Approx. 250 mA out of AS-i by supply out of AS-i
- Approx. 5 mA out of AS-i by using of an external power supply

EMC

EN 50 081-2, EN 61 000-6-2

Ambient operating temperature

0°C ... +55°C

Storage temperatureV

-25°C ... +70°C

oltage of insulation

≥ 500 V

Dimensions (L / W / H)

225mm / 130 mm / 35 mm

AS-i Specification

2.1

 

 

Connections D-sub socket 9 pins

analog outputs

alternate circuit diagram:

Pin 1

n. c.

 

Pin 2

n. c.

Pin 3

n. c.

Pin 4

n. c.

Pin 5

n. c.

Pin 6

GND

Pin 7

analog output 1+

Pin 8

GND

Pin 9

analog output 2+

 

Connections D-sub socket 25 pins

digtial outputs

alternate circuit diagram:

Pin 1

GND

 

Pin 14

+5V

 

Pin 2

output 1

Pin 15

output 12

Pin 3

output 2

Pin 16

output 13

Pin 4

output 3

Pin 17

output 14

Pin 5

output 4

Pin 18

output 15

Pin 6

output 5

Pin 19

output 16

Pin 7

output 6

Pin 20

n. c.

Pin 8

output 7

Pin 21

n. c.

Pin 9

output 8

Pin 22

n. c.

Pin 10

output 9

Pin 23

n. c.

Pin 11

output 10

Pin 24

n. c.

Pin 12

output 11

Pin 25

n. c.

Pin 13

GND

 

 

Bihl+Wiedemann GmbH

Floßwörthstr. 41

D-68199 Mannheim

Phone: (+49) 621 / 339 96-0

Fax: (+49) 621 / 339 22 39

eMail: mail@bihl-wiedemann.de