BW3813Cable Duct ASi Motor Module, IP54, M8, M12 for 24V motorized rollers, 2M/2I
Product description
Cable Duct ASi Motor Module in IP54, with 2 x M8 cable sockets and 2 x M12 cable sockets for 2 x 24 V motorized rollers Interroll (EC310), Itoh Denki (PM500XC/XK) or RULMECA (RDR BL-2), 2 digital inputs, motor control supply via AUX, input voltage/sensor supply out of ASi, internal line protection, separately for each motor 3,5 A (slow-blow fuse), flat design, installation in cable duct possible (installation depth > 19 mm), periphery connection via 2 x M8 cable sockets, straight, 5 poles and 2 x M12 cable sockets, straight, 5 poles, cable length of motor connections 0,40 m, cable length of input connections 0,06 m, ASi connection via profile cable and piercing technology, 1 AB address
Technical data
Drive
"SEW MOVIMOT®": Motor module to control geared motors with frequency inverters.
"NORD": Motor module to control geared motors with frequency inverters.
Brake chopper for 24 V motorized rollers: For limiting the voltage feedback, suitable for all 24 V motorized rollers. | Interroll EC310, Itoh Denki PM500XC/XK, RULMECA RDR BL-2 |
Number of Drives | 2 |
Inputs digital | 2 |
Input voltage (sensor supply)
inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | out of ASi |
Output voltage (actuator supply)
Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | out of AUX |
Connection | 2 x M8 snap-in cable sockets, straight, 5 poles + 2 x M12 cable sockets, straight, 5 poles |
Round cable
Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled. In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted. | M: 0,60 m, I: 1 m |
ASi address
AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed. | 1 AB address |