BWU2852Safety Basic Monitor with extended features, 1 ASi-3 master

Product description

Safety Basic Monitor with extended features, 1 ASi-3 master, integrated decoupling, max. 0,5 A/ASi network, max. 8 A with ASi power supply, ASi current measurement, 22.5 mm x 99 mm x 114 mm, with 6 x 4 contacts, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), input 3 optional for speed monitors (up to 4kHz), expandable to max. 31 x 2 channels safe inputs, 1891 x 2 channels safe inputs in max. configuration, 2 release circuits (2 x electronic safe outputs), expandable to max. 32 safe outputs, 991 safe outputs in max. configuration, Safe Link, diagnostic and configuration via Ethernet diagnostic interface, periphery connection via push-in terminals, ASi/AUX connection via push-in terminals, IP20


Safety compact controller with safety inputs and outputs.

Safety standstill/speed monitor for up to 3 axes.

Ethernet interface.

Technical data

Type Safety Basic Monitor
Safe Monitoring speed
Encoder signal/Sensor signal sensors/initiators (24V)
Number of monitored axes up to 2 independent axes
Inputs Safety, SIL 3, Cat. 4 3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz)
Outputs Safety, SIL 3, cat. 4 2 release circuits, 2 x electronic safe outputs
Encoder/Sensor connection clamps
Diagnostic and configuration interface

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.

 

 

 

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Ethernet diagnostic

How to troubleshoot an existing ASi installation

Manuals