Gateways

With the AS-i gateways from Bihl+Wiedemann you can transmit digital and analog data which have been read remotely through AS-i slaves to the host controller and set the output signals from the host controller to the actuators over the respective bus system.

 

Our gateways generally communicate according to the AS-i 3.0 standard and therefore ensure optimal exchange of the data. They are simple and quick to install and commission. The user benefits from the variety of standard implemented diagnostics functions such as duplicate address detection, earth fault and EMC monitoring as well as an optional PLC functionality.

 

Double Masters in one gateway are an especially cost-efficient approach. This allows two AS-i circuits to be controlled by one gateway. The “1 Gateway, 1 power supply for 2 AS-i circuits” version also requires just one power supply for both AS-i circuits.

 

24 Volt ASi Gateways in Stainless Steel

  • The devices can be operated directly on a 24 V (PELV) power supply.
  • With integrated data coupling coils and adjustable self-resetting fuses optimized for safe use also of powerful 24 V power supplies.
Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU305324 Volt ASi GatewayGateway IP20PROFIBUS1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkyesyesno
BWU382224 Volt ASi GatewayGateway IP20EtherNet/IP + ModbusTCP, OPC UA1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkyesyesno
BWU305824 Volt ASi GatewayGateway IP20EtherCAT1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkyesyesno
BWU331224 Volt ASi GatewayGateway IP20POWERLINK1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkyesyesno
BWU305124 Volt ASi GatewayGateway IP20CC-Link1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkyesyesno
BWU376024 Volt ASi GatewayGateway IP20PROFINET, OPC UA1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkyesyesoptional

 

 

PROFIBUS ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU2546PROFIBUS ASiGateway IP20PROFIBUS2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional
BWU2545PROFIBUS ASiGateway IP20PROFIBUS2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyEthernet diagnosticyesyesoptional
BWU1774PROFIBUS ASiGateway IP20PROFIBUS2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network-noyesno
BWU2775PROFIBUS ASiGateway IP20PROFIBUS1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional
BWU2544PROFIBUS ASiGateway IP20PROFIBUS1 ASi network, 1 ASi Masterno, max. 8 A/ASi networkEthernet diagnosticyesyesoptional
BWU1773PROFIBUS ASiGateway IP20PROFIBUS1 ASi network, 1 ASi Masterno, max. 8 A/ASi network-noyesno
BWU305324 Volt ASi GatewayGateway IP20PROFIBUS1 ASi network, 1 ASi Masteryes, max. 4 A/ASi network-yesyesno
BWU1746PROFIBUS ASi BasicGateway IP20PROFIBUS1 ASi network, 1 ASi Masterno, max. 8 A/ASi network-noyesno
BW2726Starter KitsGateway IP20PROFIBUS2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional

 

 

PROFINET ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3759PROFINET ASiGateway IP20PROFINET, OPC UA2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbusyesyesoptional
BWU3844PROFINET ASiGateway IP20PROFINET, OPC UA2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyEthernet fieldbusyesyesoptional
BWU3758PROFINET ASiGateway IP20PROFINET, OPC UA1 ASi network, 1 ASi Masterno, max. 8 A/ASi networkEthernet fieldbusyesyesoptional
BWU3431PROFINET ASiGateway IP20PROFINET1 ASi network, 1 ASi Masterno, max. 8 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional
BWU376024 Volt ASi GatewayGateway IP20PROFINET, OPC UA1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet fieldbusyesyesoptional

 

 

EtherNet/IP + ModbusTCP ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3736EtherNet/IP + ModbusTCP ASiGateway IP20EtherNet/IP + ModbusTCP, OPC UA2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbusyesyesoptional
BWU3735EtherNet/IP + ModbusTCP ASiGateway IP20EtherNet/IP + ModbusTCP, OPC UA2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyEthernet fieldbusyesyesoptional
BWU3734EtherNet/IP + ModbusTCP ASiGateway IP20EtherNet/IP + ModbusTCP, OPC UA1 ASi network, 1 ASi Masterno, max. 8 A/ASi networkEthernet fieldbusyesyesoptional
BWU382224 Volt ASi GatewayGateway IP20EtherNet/IP + ModbusTCP, OPC UA1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet fieldbusyesyesno

 

 

BACnet/TCP ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3356BACnet/TCP ASiGateway IP20BACnet/TCP2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyEthernet fieldbus + Ethernet diagnosticyesyesoptional

 

 

DeviceNet ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1820DeviceNet ASiGateway IP20DeviceNet2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkRS 232yesyesno
BWU1819DeviceNet ASiGateway IP20DeviceNet2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyRS 232yesyesno
BWU1818DeviceNet ASiGateway IP20DeviceNet1 ASi network, 1 ASi Masterno, max. 8 A/ASi networkRS 232yesyesno

 

 

ControlLogix ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1488ControlLogix ASiGateway IP20ControlLogix2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi networkRS 232nonono
BW1611ControlLogix ASiGateway IP20complete set ControlLogix2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi networkRS 232nonono

 

 

Compact- / MicroLogix ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1416Compact- / MicroLogix ASiGateway IP20CompactLogix, MicroLogix15001 ASi network, 1 ASi Masterno, max. 8 A/ASi networkRS 232nonono
BW1610Compact- / MicroLogix ASiGateway IP20complete set CompactLogix, MicroLogix15001 ASi network, 1 ASi Masterno, max. 8 A/ASi networkRS 232nonono

 

 

EtherCAT ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU2720EtherCAT ASiGateway IP20EtherCAT2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesno
BWU2163EtherCAT ASiGateway IP20EtherCAT2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyRS 232yesyesno
BWU2162EtherCAT ASiGateway IP20EtherCAT1 ASi network, 1 ASi Masterno, max. 8 A/ASi networkRS 232yesyesno
BWU305824 Volt ASi GatewayGateway IP20EtherCAT1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet fieldbusyesyesno

 

 

CC-Link ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU2611CC-Link ASiGateway IP20CC-Link1 ASi network, 1 ASi Masterno, max. 8 A/ASi networknoyesno
BWU305124 Volt ASi GatewayGateway IP20CC-Link1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkyesyesno

 

 

POWERLINK ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3593POWERLINK ASiGateway IP20POWERLINK2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional
BWU3537POWERLINK ASiGateway IP20POWERLINK2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyEthernet diagnosticyesyesoptional
BWU331224 Volt ASi GatewayGateway IP20POWERLINK1 ASi network, 1 ASi Masteryes, max. 4 A/ASi network-yesyesno

 

 

CANopen ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1823CANopen ASiGateway IP20CANopen2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkRS 232yesyesno
BWU1822CANopen ASiGateway IP20CANopen2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyRS 232yesyesno
BWU1821CANopen ASiGateway IP20CANopen1 ASi network, 1 ASi Masterno, max. 8 A/ASi networkRS 232yesyesno

 

 

RS 485 Modbus ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1643RS 485 Modbus ASiGateway IP20Modbus/RTU; RS 4852 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkRS 232yesyesno
BWU1642RS 485 Modbus ASiGateway IP20Modbus/RTU; RS 4852 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyRS 232yesyesno
BWU1641RS 485 Modbus ASiGateway IP20Modbus/RTU; RS 4851 ASi network, 1 ASi Masterno, max. 8 A/ASi networkRS 232yesyesno

 

 

RS232 ASi

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1955RS 232 ASiGateway IP20RS 2321 ASi network, 1 ASi Masterno, max. 8 A/ASi networknoyesno

 

 

Safety, PROFIBUS

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2822Safety, PROFIBUSGateway with integrated Safety MonitorIP20PROFIBUS2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BWU2602Safety, PROFIBUSGateway with integrated Safety MonitorIP20PROFIBUS2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional4-max. 62 x 2 channels, max. 1922 in max. configuration4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BWU2202Safety, PROFIBUSGateway with integrated Safety MonitorIP20PROFIBUS2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesno4-max. 62 x 2 channels4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 16 -
BWU2204Safety, PROFIBUSGateway with integrated Safety MonitorIP20PROFIBUS2 ASi networks, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesno4-max. 62 x 2 channels4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 16 -
BWU2206Safety, PROFIBUSGateway with integrated Safety MonitorIP20PROFIBUS2 ASi networks, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesno4-max. 62 x 2 channels2 release circuits; 2 x 2 relaymax. 16 -
BWU2793Safety, PROFIBUSGateway with integrated Safety MonitorIP20PROFIBUS1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 31, max. 991 in max. configurationSafe Link
BW2695Starter KitsGateway with integrated Safety MonitorIP20PROFIBUS2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional4-max. 62 x 2 channels, max. 1922 in max. configuration4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link

 

Safety, PROFINET

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2828Safety, PROFINETGateway with integrated Safety MonitorIP20PROFINET2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BWU2642Safety, PROFINETGateway with integrated Safety MonitorIP20PROFINET2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + RS 232yesyesoptional4-max. 62 x 2 channels, max. 1922 in max. configuration4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BWU3080Safety, PROFINETGateway with integrated Safety MonitorIP20PROFINET2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BWU2798Safety, PROFINETGateway with integrated Safety MonitorIP20PROFINET1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 31, max. 991 in max. configurationSafe Link
BW3000Starter KitsGateway with integrated Safety MonitorIP20PROFINET2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BW3074Starter KitsGateway with integrated Safety MonitorIP20PROFINET1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 31, max. 991 in max. configurationSafe Link

 

PROFIsafe, PROFIBUS

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2615PROFIsafe, PROFIBUSGateway with integrated Safety MonitorIP20PROFIBUS2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional4-max. 62 x 2 channels4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 16 PROFIsafe (F-CPU) + ASIMON program
BWU2598PROFIsafe, PROFIBUSGateway with integrated Safety MonitorIP20PROFIBUS2 ASi networks, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional4-max. 62 x 2 channels4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 16 PROFIsafe (F-CPU) + ASIMON program
BWU2819PROFIsafe, PROFIBUSGateway with integrated Safety MonitorIP20PROFIBUS1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels6 release circuits; 6 x fast electronic safe outputsmax. 31PROFIsafe (F-CPU) + ASIMON program
BWU2479PROFIsafe, PROFIBUSGateway with integrated Safety MonitorIP20PROFIBUS1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkRS 232yesyesno--max. 31 x 2 channels-max. 16 PROFIsafe (F-CPU)

 

PROFIsafe, PROFINET

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU3674PROFIsafe, PROFINET, ASi-5 / ASi-3Gateway with integrated Safety MonitorIP20PROFINET, OPC UA2 ASi networks, 2 ASi-5/ASi-3 mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 64, max. 1984 in max. configurationPROFIsafe (F-CPU) + ASIMON program + Safe Link
BWU3823PROFIsafe, PROFINETGateway with integrated Safety MonitorIP20PROFINET, OPC UA2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 64, max. 1984 in max. configurationPROFIsafe (F-CPU) + ASIMON program + Safe Link
BWU3367PROFIsafe, PROFINETGateway with integrated Safety MonitorIP20PROFINET2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 64, max. 1984 in max. configurationPROFIsafe (F-CPU) + ASIMON program + Safe Link
BWU2805PROFIsafe, PROFINETGateway with integrated Safety MonitorIP20PROFINET2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional--max. 62 x 2 channels-max. 16 PROFIsafe (F-CPU) + ASIMON program
BWU2647PROFIsafe, PROFINETGateway with integrated Safety MonitorIP20PROFINET2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + RS 232yesyesoptional4-max. 62 x 2 channels4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 16 PROFIsafe (F-CPU) + ASIMON program
BWU2794PROFIsafe, PROFINETGateway with integrated Safety MonitorIP20PROFINET1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels6 release circuits; 6 x fast electronic safe outputsmax. 31PROFIsafe (F-CPU) + ASIMON program

 

 

Safety, Sercos

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU3160Safety, SercosGateway with integrated Safety MonitorIP20Sercos2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 64, max. 1984 in max. configurationCIP Safety over Sercos + Safe Link
BWU2984Safety, SercosGateway with integrated Safety MonitorIP20Sercos2 ASi networks, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 64, max. 1984 in max. configurationsafe Schneider drives over Sercos + Safe Link
BWU2588Safety, SercosGateway with integrated Safety MonitorIP20Sercos2 ASi networks, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional4-max. 62 x 2 channels, max. 1922 in max. configuration4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link

 

Safety, EtherNet/IP + ModbusTCP

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU3857Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3Gateway with integrated Safety MonitorIP20EtherNet/IP + ModbusTCP, OPC UA2 ASi networks, 2 ASi-5/ASi-3 mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 64, max. 1984 in max. configurationCIP Safety over EtherNet/IP + Safe Link
BWU3683Safety, EtherNet/IP + ModbusTCPGateway with integrated Safety MonitorIP20EtherNet/IP + ModbusTCP, OPC UA2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 64, max. 1984 in max. configurationCIP Safety over EtherNet/IP + Safe Link
BWU2742Safety, EtherNet/IP + ModbusTCPGateway with integrated Safety MonitorIP20EtherNet/IP + ModbusTCP2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels6 release circuits; 6 x fast electronic safe outputsmax. 64CIP Safety over EtherNet/IP
BWU3543Safety, EtherNet/IP + ModbusTCPGateway with integrated Safety MonitorIP20EtherNet/IP + ModbusTCP2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BWU3544Safety, EtherNet/IP + ModbusTCPGateway with integrated Safety MonitorIP20EtherNet/IP + ModbusTCP2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BWU2579Safety, EtherNet/IP + ModbusTCPGateway with integrated Safety MonitorIP20EtherNet/IP + ModbusTCP2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional4-max. 62 x 2 channels, max. 1922 in max. configuration4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BWU3542Safety, EtherNet/IP + ModbusTCPGateway with integrated Safety MonitorIP20EtherNet/IP + ModbusTCP1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 31, max. 991 in max. configurationSafe Link

 

 

Safety, DeviceNet

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2972Safety, DeviceNetGateway with integrated Safety MonitorIP20DeviceNet1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 31, max. 991 in max. configurationSafe Link

 

Safety, EtherCAT

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU3418Safety, EtherCATGateway with integrated Safety MonitorIP20EtherCAT2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 64, max. 1984 in max. configurationFSoE + Safe Link
BWU2944Safety, EtherCATGateway with integrated Safety MonitorIP20EtherCAT2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BWU3509Safety, EtherCATGateway with integrated Safety MonitorIP20EtherCAT1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 32, max. 992 in max. configurationFSoE + Safe Link
BWU2797Safety, EtherCATGateway with integrated Safety MonitorIP20EtherCAT1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 31, max. 991 in max. configurationSafe Link

 

Safety, POWERLINK

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs Safety, SIL 3, Cat. 4

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3176Safety, POWERLINKGateway with integrated Safety MonitorIP203 x 2 channels6max. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe LinkPOWERLINK2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional
BWU3177Safety, POWERLINKGateway with integrated Safety MonitorIP203 x 2 channels6max. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 31, max. 991 in max. configurationSafe LinkPOWERLINK1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional

 

Safety, CANopen

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2804Safety, CANopenGateway with integrated Safety MonitorIP20CANopen1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 31, max. 991 in max. configurationSafe Link

 

Safety, CC-Link

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2833Safety, CC-LinkGateway with integrated Safety MonitorIP20CC-Link1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 31, max. 991 in max. configurationSafe Link

 

Starter Kits

  • Fully assembled and wired in a practical case
Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/TCP ASi gateway: interface for a BACnet/TCP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

Fieldbus interface

Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BW2726Starter KitsGateway IP20PROFIBUS2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional------
BW2695Starter KitsGateway with integrated Safety MonitorIP20PROFIBUS2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional4-max. 62 x 2 channels, max. 1922 in max. configuration4 release circuits; 2 x relay, 2 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BW3000Starter KitsGateway with integrated Safety MonitorIP20PROFINET2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 62 x 2 channels, max. 1922 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 32, max. 992 in max. configurationSafe Link
BW3074Starter KitsGateway with integrated Safety MonitorIP20PROFINET1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits; 6 x fast electronic safe outputsmax. 31, max. 991 in max. configurationSafe Link