Safety Monitor
Figure |
Type
|
ASi-5/ASi-3
|
Model
|
Protection rating
|
Inputs Safety, SIL 3, Cat. 4
|
Inputs digital, EDM
|
Inputs safety, expandable to
|
Outputs Safety, SIL 3, cat. 4
|
Safety outputs, independent according to SIL 3, expandable to
|
Safety communication
|
Fieldbus interface
|
Number of ASi networks, number of ASi Master
|
1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies
|
Diagnostic and configuration interface
|
Recognition of duplicate ASi addresses
|
ASi fault detector
|
Programming in C
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Safety Basic Monitor | ASi-3 compatible | Safety Basic Monitor with extended features | IP20 | 4 x 2 channels, inputs 3+4, compatible as replacement with consortial monitor | 8 | max. 31 x 2 channels | 2 release circuits, 2 x electronic safe outputs | max. 16 | - | ASi monitors | 1 ASi network, 1 ASi Master | no, max. 8 A/ASi network | USB | no | no | no | |
Safety Basic Monitor | ASi-3 compatible | Safety Basic Monitor with extended features | IP20 | 4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz) | 8 | max. 31 x 2 channels | 2 release circuits, 2 x electronic safe outputs | max. 16 | - | Signaling contacts | 1 ASi network, 1 ASi Master | yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply | USB | no | no | no | |
Safety Basic Monitor | ASi-3 compatible | Safety Basic Monitor with extended features | IP20 | 3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz) | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 2 release circuits, 2 x electronic safe outputs | max. 32, max. 991 in max. configuration | Safe Link | Signaling contacts | 1 ASi network, 1 ASi Master | yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply | Ethernet diagnostic + Modbus TCP diagnostic | no | no | no | |
Starter Kits | ASi-3 compatible | Safety Basic Monitor with extended features | IP20 | 4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz) | 8 | max. 31 x 2 channels | 2 release circuits, 2 x electronic safe outputs | max. 8 | - | Signaling contacts | 1 ASi network, 1 ASi Master | yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply | USB | no | no | no | |
Safety, PROFIBUS | ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 32, max. 992 in max. configuration | Safe Link | PROFIBUS | 2 ASi networks, 2 ASi Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
Safety, PROFIBUS | ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | PROFIBUS | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
PROFIsafe, PROFIBUS | ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels | 6 release circuits, 6 x electronic safe outputs | max. 31 | PROFIsafe (F-CPU) + ASIMON program | PROFIBUS | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
PROFIsafe, PROFINET, ASi-5 / ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | PROFIsafe (F-CPU) + ASIMON program + Safe Link | PROFINET, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | |
PROFIsafe, PROFINET, ASi-5 / ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | PROFIsafe (F-CPU) + ASIMON program + Safe Link | PROFINET, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | |
Safety, PROFINET ASi-5/ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | Safe Link | PROFINET, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | |
Safety, PROFINET ASi-5/ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | PROFINET, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | |
PROFIsafe, PROFINET, ASi-5 / ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | - | - | max. 31 x 2 channels, max. 1891 in max. configuration | - | max. 64, max. 1984 in max. configuration | PROFIsafe (F-CPU) + ASIMON program + Safe Link | PROFINET, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | - | yes | optional | |
Safety, PROFINET ASi-5/ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | - | - | max. 31 x 2 channels, max. 1891 in max. configuration | - | max. 64, max. 1984 in max. configuration | Safe Link | PROFINET, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | |
Safety, Sercos ASi-5/ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | safe Schneider drives over Sercos + Safe Link | Sercos, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
Safety, Sercos ASi-5/ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | CIP Safety over Sercos + Safe Link | Sercos, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
Safety, Sercos ASi-5/ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | - | - | max. 62 x 2 channels, max. 1922 in max. configuration | - | max. 64, max. 1984 in max. configuration | CIP Safety over Sercos + Safe Link | Sercos, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | CIP Safety over EtherNet/IP + Safe Link | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | |
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | Safe Link | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | |
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | EtherNet/IP + ModbusTCP, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | |
Safety, EtherNet/IP + ModbusTCP | ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 32, max. 992 in max. configuration | Safe Link | EtherNet/IP + ModbusTCP | 2 ASi networks, 2 ASi Masters | no, max. 8 A/ASi network, redundant supply | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | |
Safety, BACnet/IP | ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 128 x 2 channels, max. 3968 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 128, max. 3968 in max. configuration | Safe Link | BACnet/IP, OPC UA | 2 ASi networks, 2 ASi Masters | no, max. 8 A/ASi network, redundant supply | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | |
Safety, DeviceNet | ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | DeviceNet | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
Safety, EtherCAT ASi-5/ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | FSoE + Safe Link | EtherCAT, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
Safety, EtherCAT ASi-5/ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | Safe Link | EtherCAT, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
POWERLINK ASi-5/ASi-3 | ASi-5 + ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | Safe Link | POWERLINK | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
Safety, POWERLINK | ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 32, max. 992 in max. configuration | Safe Link | POWERLINK | 2 ASi networks, 2 ASi Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
Safety, POWERLINK | ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | POWERLINK | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
Safety, CANopen | ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | CANopen | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | |
Safety, CC-Link | ASi-3 compatible | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | CC-Link | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional |