Speed Monitoring
Bihl+Wiedemann offers a variety of devices for safe speed monitoring. The video gives an overview of the functions, applications and interfaces of these modules.
Extremely Compact and Cost-Efficient
Safe Speed Monitors for Sensors/Initiators: Safety Basic Monitors
- Autonomous compact safety controller
- 4 × 2-channel safe inputs or standard inputs and status outputs
- Speed monitor on the local inputs
- 2 axes 2-channel (SIL2, PLd) or SIL3, PLe)
- 4 axes 1-channel (SIL1, PLc)
- Standstill monitor on the local inputs
- 4 axes 2-channel (SIL2, PLd)
- 2 safe electronic outputs
- USB or Ethernet interface for configuration
- Detailed diagnostics and shut-off history via software or control
- Chip card for easy device exchange
Maximum Functionality
Safe speed monitors for encoders
- Monitor up to 2 axes, up to SIL3, PLe
- For sine/cosine, SSI, TTL or HTL-Encoder
- Detailed diagnostics and shut-off history via software
- Chip card for easy device exchange
- 22.5 mm width
Devices with local safe outputs
- 2 safe electronic outputs
- Support of all safety functions acc. EN 61800-5-2
- Any number of safety functions can be implemented
- Possibility to configure several functions or same function with different parameters for each axis
- Max. 128 devices configurable
What speed monitors are able to do
Safe monitoring of:
- Standstill
- Speed
- Speed range
- Direction
- Shaft break
- Belt misalignment
- Slippage
Even for different gear trains
- Break control
- Position
- End position
- Position range
Safety Gateways with Safe Fieldbus Connection
Safe speed monitoring in the drive
Motors with integrated Speed Monitor and safe fieldbus connection easily controlled using our Safety Gateway:
- CIP Safety via Sercos
- Safety over EtherCAT (FSoE)
Of course Bihl+Wiedemann also offers Safety Gateways for combining with a Safe PLC (F-CPU):
(Click to enlarge)
Safety Gateway and frequency inverters with integrated Speed Monitor connected over a safe fieldbus.
Applications
Safe speed and position monitoring with encoders
Software
ASIMON360
(Click to enlarge)
- Simple and intuitivediagnostic and configuration software Switch-off history
- Configuration of I/O modules and speed monitors
- Online diagnostics
- Remote maintenance
Diagnostics over Fieldbus
Safe speed monitoring in the gateway or module
- 12 terminals on the integrated Safety Monitor freely configurable, e.g.:
- 6 safe outputs plus 3 safe 2-channel inputs
- 6 safe 2-channel inputs
- Standard I/Os
- Any combination thereof
- Speed monitor on the local inputs
- 3 axes 2-channel (SIL2, PLd)
- 6 axes 1-channel (SIL1, PLc)
Simple Connection
Adapter modules for simple connection between the frequency inverter and encoder cable
- Adapter for connecting 2 encoders
- Inverter and encoder connection use screw terminals
- Sub D cable adapter 9-pole/15-pole
- Y-tap
- Integrated RJ45/Mini IO connector cable
Special assemblies on request
Connecting cable, RJ45, mini-IO connector, connector-ferrules
- RJ45 on RJ45
- RJ45 on Mini-IO
- Mini-IO on connector-ferrules
- RJ45 on connector-ferrules
Connection options Speed Monitor
The Bihl+Wiedemann System
- Interface to all common fieldbus systems
- All diagnostic data available in the controller
- Safety and standard signals
- Up to 62 safe modules/head stations
- Safe coupling of up to 31 head stations over standard Ethernet
- Expandable via unshielded, 2-conductor cable
- Safe and standard I/Os over the same cable
- Decentralized installation possible