Logo Bihl+Wiedemann GmbH

EtherNet/IP + Modbus/TCP

What is EtherNet/IP?

EtherNet/IP (Ethernet Industrial Protocol) is an open, CIP-based fieldbus standard developed by Rockwell Automation and the ODVA (Open DeviceNet Vendor Association) which is used mainly in automation technology. EtherNet/IP enables communication between devices made by different manufacturers without any special interface adaptations.

What is Modbus/TCP?

Modbus TCP/IP is an open fieldbus standard for industrial communication using ethernet. It is used mainly in automation technology and enables communication between devices from different manufacturers without any special interface adaptations.

Products

EtherNet/IP + Modbus/TCP AS-i Gateways

EtherNet/IP + Modbus/TCP AS-i Gateways in stainless steel provide an interface for an EtherNet/IP + Modbus/TCP fieldbus. These AS-i gateways are available in various versions with IP20 protection rating.

EtherNet/IP + Modbus/TCP AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU2381 EtherNet/IP + ModbusTCP AS-i Gateway IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + RS 232 yes yes optional
BWU2380 EtherNet/IP + ModbusTCP AS-i Gateway IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet fieldbus + RS 232 yes yes optional
BWU2379 EtherNet/IP + ModbusTCP AS-i Gateway IP20 EtherNet/IP + Modbus/TCP 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network Ethernet fieldbus + RS 232 yes yes optional
BWU3050 24 Volt AS-i Gateway Gateway IP20 EtherNet/IP + Modbus/TCP 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet fieldbus yes yes no

Safety, EtherNet/IP + Modbus/TCP AS-i Gateways

Safety, EtherNet/IP + Modbus/TCP AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2742 Safety, EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels 6 release circuits; 6 x fast electronic safe outputs max. 64 CIP Safety over EtherNet/IP
BWU2821 Safety, EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU3079 Safety, EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU2818 Safety, EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor IP20 EtherNet/IP + Modbus/TCP 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link
BWU2579 Safety, EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 4 - max. 62 x 2 channels, max. 1922 in max. configuration 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link

EtherNet/IP + Modbus/TCP Zubehör


Questions about our products and solutions?