Gateways

With the AS-i gateways from Bihl+Wiedemann you can transmit digital and analog data which have been read remotely through AS-i slaves to the host controller and set the output signals from the host controller to the actuators over the respective bus system.

 

Our gateways generally communicate according to the AS-i 3.0 standard and therefore ensure optimal exchange of the data. They are simple and quick to install and commission. The user benefits from the variety of standard implemented diagnostics functions such as duplicate address detection, earth fault and EMC monitoring as well as an optional PLC functionality.

 

Double Masters in one gateway are an especially cost-efficient approach. This allows two AS-i circuits to be controlled by one gateway. The “1 Gateway, 1 power supply for 2 AS-i circuits” version also requires just one power supply for both AS-i circuits.

 

24 Volt AS-i Gateways in Stainless Steel

  • The devices can be operated directly on a 24 V (PELV) power supply.
  • With integrated data coupling coils and adjustable self-resetting fuses optimized for safe use also of powerful 24 V power supplies.
Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3053 24 Volt AS-i Gateway Gateway IP20 PROFIBUS 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network yes yes no
BWU2919 24 Volt AS-i Gateway Gateway IP20 PROFINET 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network yes yes optional
BWU3050 24 Volt AS-i Gateway Gateway IP20 EtherNet/IP + Modbus/TCP 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network yes yes no
BWU3058 24 Volt AS-i Gateway Gateway IP20 EtherCAT 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network yes yes no
BWU3312 24 Volt AS-i Gateway Gateway IP20 POWERLINK 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network yes yes no
BWU3051 24 Volt AS-i Gateway Gateway IP20 CC-Link 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network yes yes no

PROFIBUS AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU2546 PROFIBUS AS-i Gateway IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional
BWU2545 PROFIBUS AS-i Gateway IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet diagnostic yes yes optional
BWU1774 PROFIBUS AS-i Gateway IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network - no yes no
BWU2775 PROFIBUS AS-i Gateway IP20 PROFIBUS 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional
BWU2544 PROFIBUS AS-i Gateway IP20 PROFIBUS 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network Ethernet diagnostic yes yes optional
BWU1773 PROFIBUS AS-i Gateway IP20 PROFIBUS 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network - no yes no
BWU3053 24 Volt AS-i Gateway Gateway IP20 PROFIBUS 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network - yes yes no
BWU1746 PROFIBUS AS-i Basic Gateway IP20 PROFIBUS 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network - no yes no
BW2726 Starter Kits Gateway IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional

PROFINET AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3363 PROFINET AS-i Gateway IP20 PROFINET 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus yes yes optional
BWU3122 PROFINET AS-i Gateway IP20 PROFINET 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet fieldbus yes yes optional
BWU2729 PROFINET AS-i Gateway IP20 PROFINET 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network Ethernet fieldbus yes yes optional
BWU3431 PROFINET AS-i Gateway IP20 PROFINET 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional
BWU2919 24 Volt AS-i Gateway Gateway IP20 PROFINET 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet fieldbus yes yes optional

EtherNet/IP + ModbusTCP AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU2381 EtherNet/IP + ModbusTCP AS-i Gateway IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + RS 232 yes yes optional
BWU2380 EtherNet/IP + ModbusTCP AS-i Gateway IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet fieldbus + RS 232 yes yes optional
BWU2379 EtherNet/IP + ModbusTCP AS-i Gateway IP20 EtherNet/IP + Modbus/TCP 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network Ethernet fieldbus + RS 232 yes yes optional
BWU3050 24 Volt AS-i Gateway Gateway IP20 EtherNet/IP + Modbus/TCP 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet fieldbus yes yes no

BACnet/IP AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3356 BACnet/IP AS-i Gateway IP20 BACnet/IP 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet fieldbus + Ethernet diagnostic yes yes optional

DeviceNet AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1820 DeviceNet AS-i Gateway IP20 DeviceNet 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network RS 232 yes yes no
BWU1819 DeviceNet AS-i Gateway IP20 DeviceNet 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply RS 232 yes yes no
BWU1818 DeviceNet AS-i Gateway IP20 DeviceNet 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network RS 232 yes yes no

ControlLogix AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1488 ControlLogix AS-i Gateway IP20 ControlLogix 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network RS 232 no no no
BW1611 ControlLogix AS-i Gateway IP20 complete set ControlLogix 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network RS 232 no no no

Compact- / MicroLogix AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1416 Compact- / MicroLogix AS-i Gateway IP20 CompactLogix, MicroLogix1500 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network RS 232 no no no
BW1610 Compact- / MicroLogix AS-i Gateway IP20 complete set CompactLogix, MicroLogix1500 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network RS 232 no no no

EtherCAT AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU2720 EtherCAT AS-i Gateway IP20 EtherCAT 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes no
BWU2163 EtherCAT AS-i Gateway IP20 EtherCAT 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply RS 232 yes yes no
BWU2162 EtherCAT AS-i Gateway IP20 EtherCAT 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network RS 232 yes yes no
BWU3058 24 Volt AS-i Gateway Gateway IP20 EtherCAT 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet fieldbus yes yes no

CC-Link AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU2611 CC-Link AS-i Gateway IP20 CC-Link 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network no yes no
BWU3051 24 Volt AS-i Gateway Gateway IP20 CC-Link 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network yes yes no

POWERLINK AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3593 POWERLINK AS-i Gateway IP20 POWERLINK 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional
BWU3537 POWERLINK AS-i Gateway IP20 POWERLINK 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet diagnostic yes yes optional

CANopen AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1823 CANopen AS-i Gateway IP20 CANopen 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network RS 232 yes yes no
BWU1822 CANopen AS-i Gateway IP20 CANopen 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply RS 232 yes yes no
BWU1821 CANopen AS-i Gateway IP20 CANopen 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network RS 232 yes yes no

RS 485 Modbus AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1643 RS 485 Modbus AS-i Gateway IP20 Modbus/RTU; RS 485 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network RS 232 yes yes no
BWU1642 RS 485 Modbus AS-i Gateway IP20 Modbus/RTU; RS 485 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply RS 232 yes yes no
BWU1641 RS 485 Modbus AS-i Gateway IP20 Modbus/RTU; RS 485 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network RS 232 yes yes no

RS232 AS-i

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1955 RS 232 AS-i Gateway IP20 RS 232 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network no yes no

Safety, PROFIBUS

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2822 Safety, PROFIBUS Gateway with integrated Safety Monitor IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU2602 Safety, PROFIBUS Gateway with integrated Safety Monitor IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 4 - max. 62 x 2 channels, max. 1922 in max. configuration 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU2202 Safety, PROFIBUS Gateway with integrated Safety Monitor IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes no 4 - max. 62 x 2 channels 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 16 -
BWU2204 Safety, PROFIBUS Gateway with integrated Safety Monitor IP20 PROFIBUS 2 AS-i networks, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes no 4 - max. 62 x 2 channels 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 16 -
BWU2206 Safety, PROFIBUS Gateway with integrated Safety Monitor IP20 PROFIBUS 2 AS-i networks, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes no 4 - max. 62 x 2 channels 2 release circuits; 2 x 2 relay max. 16 -
BWU2793 Safety, PROFIBUS Gateway with integrated Safety Monitor IP20 PROFIBUS 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link
BW2695 Starter Kits Gateway with integrated Safety Monitor IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 4 - max. 62 x 2 channels, max. 1922 in max. configuration 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link

Safety, PROFINET

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2828 Safety, PROFINET Gateway with integrated Safety Monitor IP20 PROFINET 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU2642 Safety, PROFINET Gateway with integrated Safety Monitor IP20 PROFINET 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + RS 232 yes yes optional 4 - max. 62 x 2 channels, max. 1922 in max. configuration 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU3080 Safety, PROFINET Gateway with integrated Safety Monitor IP20 PROFINET 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU2798 Safety, PROFINET Gateway with integrated Safety Monitor IP20 PROFINET 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link
BW3000 Starter Kits Gateway with integrated Safety Monitor IP20 PROFINET 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BW3074 Starter Kits Gateway with integrated Safety Monitor IP20 PROFINET 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link

PROFIsafe, PROFIBUS

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2615 PROFIsafe, PROFIBUS Gateway with integrated Safety Monitor IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 4 - max. 62 x 2 channels 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 16 PROFIsafe (F-CPU) + ASIMON program
BWU2598 PROFIsafe, PROFIBUS Gateway with integrated Safety Monitor IP20 PROFIBUS 2 AS-i networks, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 4 - max. 62 x 2 channels 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 16 PROFIsafe (F-CPU) + ASIMON program
BWU2819 PROFIsafe, PROFIBUS Gateway with integrated Safety Monitor IP20 PROFIBUS 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels 6 release circuits; 6 x fast electronic safe outputs max. 31 PROFIsafe (F-CPU) + ASIMON program
BWU2479 PROFIsafe, PROFIBUS Gateway with integrated Safety Monitor IP20 PROFIBUS 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network RS 232 yes yes no - - max. 31 x 2 channels - max. 16 PROFIsafe (F-CPU)

PROFIsafe, PROFINET

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU3367 PROFIsafe, PROFINET Gateway with integrated Safety Monitor IP20 PROFINET 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 64, max. 1984 in max. configuration PROFIsafe (F-CPU) + ASIMON program + Safe Link
BWU2805 PROFIsafe, PROFINET Gateway with integrated Safety Monitor IP20 PROFINET 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional - - max. 62 x 2 channels - max. 16 PROFIsafe (F-CPU) + ASIMON program
BWU2647 PROFIsafe, PROFINET Gateway with integrated Safety Monitor IP20 PROFINET 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + RS 232 yes yes optional 4 - max. 62 x 2 channels 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 16 PROFIsafe (F-CPU) + ASIMON program
BWU2794 PROFIsafe, PROFINET Gateway with integrated Safety Monitor IP20 PROFINET 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels 6 release circuits; 6 x fast electronic safe outputs max. 31 PROFIsafe (F-CPU) + ASIMON program

Safety, Sercos

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU3160 Safety, Sercos Gateway with integrated Safety Monitor IP20 Sercos 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 64, max. 1984 in max. configuration CIP Safety over Sercos + Safe Link
BWU2984 Safety, Sercos Gateway with integrated Safety Monitor IP20 Sercos 2 AS-i networks, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 64, max. 1984 in max. configuration safe Schneider drives over Sercos + Safe Link
BWU2588 Safety, Sercos Gateway with integrated Safety Monitor IP20 Sercos 2 AS-i networks, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 4 - max. 62 x 2 channels, max. 1922 in max. configuration 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link

Safety, EtherNet/IP + ModbusTCP

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2742 Safety, EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels 6 release circuits; 6 x fast electronic safe outputs max. 64 CIP Safety over EtherNet/IP
BWU2821 Safety, EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU2579 Safety, EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 4 - max. 62 x 2 channels, max. 1922 in max. configuration 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU3079 Safety, EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU2818 Safety, EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor IP20 EtherNet/IP + Modbus/TCP 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link

Safety, DeviceNet

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2972 Safety, DeviceNet Gateway with integrated Safety Monitor IP20 DeviceNet 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link

Safety, EtherCAT

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU3418 Safety, EtherCAT Gateway with integrated Safety Monitor IP20 EtherCAT 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 64, max. 1984 in max. configuration FSoE + Safe Link
BWU2944 Safety, EtherCAT Gateway with integrated Safety Monitor IP20 EtherCAT 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BWU3509 Safety, EtherCAT Gateway with integrated Safety Monitor IP20 EtherCAT 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration FSoE + Safe Link
BWU2797 Safety, EtherCAT Gateway with integrated Safety Monitor IP20 EtherCAT 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link

Safety, POWERLINK

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs Safety, SIL 3, Cat. 4

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3176 Safety, POWERLINK Gateway with integrated Safety Monitor IP20 3 x 2 channels 6 max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link POWERLINK 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional
BWU3177 Safety, POWERLINK Gateway with integrated Safety Monitor IP20 3 x 2 channels 6 max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link POWERLINK 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional

Safety, CANopen

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2804 Safety, CANopen Gateway with integrated Safety Monitor IP20 CANopen 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link

Safety, CC-Link

Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2833 Safety, CC-Link Gateway with integrated Safety Monitor IP20 CC-Link 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link

Starter Kits

  • Fully assembled and wired in a practical case
Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BW2726 Starter Kits Gateway IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional - - - - - -
BW2695 Starter Kits Gateway with integrated Safety Monitor IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet diagnostic yes yes optional 4 - max. 62 x 2 channels, max. 1922 in max. configuration 4 release circuits; 2 x relay, 2 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BW3000 Starter Kits Gateway with integrated Safety Monitor IP20 PROFINET 2 AS-i networks, 2 AS-i Masters yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 62 x 2 channels, max. 1922 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 32, max. 992 in max. configuration Safe Link
BW3074 Starter Kits Gateway with integrated Safety Monitor IP20 PROFINET 1 AS-i network, 1 AS-i Master yes, max. 4 A/AS-i network Ethernet fieldbus + Ethernet diagnostic yes yes optional 6 3 x 2 channels max. 31 x 2 channels, max. 1891 in max. configuration 6 release circuits; 6 x fast electronic safe outputs max. 31, max. 991 in max. configuration Safe Link