Drive solutions
BWU3640Active Distributor ASi Motor Module for Lenze Smart Motor, IP67, 4I/3O
Product description
Active Distributor ASi Motor Module, IP67, housing depth 35 mm, for 1 x Lenze Smart Motor, 4 digital inputs, 3 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 2 x M12 cable sockets, straight, 5 poles, cable length 2 m, 1 x M12 cable sockets, straight, 8 poles, cable length 2 m, flat design, installation in cable duct possible (installation depth ≥ 35 mm), LED, connections for 1 x ASi profile cable, ASi connection via profile cable and piercing technology, 1 AB slave
Technical data
Type | Active distributor ASi motor module | ||||||||||||||||||||
Housing | depth: 35 mm | ||||||||||||||||||||
Protection rating
"IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | IP67 | ||||||||||||||||||||
Drive
"SEW MOVIMOT®": Motor module to control geared motors with frequency inverters. Motor module to control motor starters MOVI-SWITCH® 1E. Motor module to control motor starters MOVI-SWITCH® 2S or to control Lenze Smart motors. Motor module to control Lenze Smart motors and to control additional sensors. Motor module to control 24 V motorized rollers Itoh Denki Serie Power Moller® 500ME/XE/XP and Serie Power Moller® 605ME/XE/XP. Motor module to control 24 V motorized rollers Interroll Typ EC310 or RULMECA Typ RDR BL-2. Motor module to control 24 V motorized rollers Interroll Typ EC200 and EC300 or Rollex Typ 840. Motor module to control 24 V motorized rollers Interroll Typ EC310 (also suitable for EC200 and EC300) or RULMECA Typ RDR BL-2 or Itoh Denki Serie Power Moller® 500ME/XE/XP and Serie Power Moller® 605ME/XE/XP. | Lenze Smart Motor | ||||||||||||||||||||
Number of Drives | 1 | ||||||||||||||||||||
Line protection fuse
"yes, separatly for each motor, 3,5 A (slow-blow fuse)": In the motor module UL approved fuses are placed before each of the motor supply connections. A short circuit in the motor causes this fuse to blow, protecting the connection cable between the module and motor. After blowing the fuse the module is no longer functional and needs to be replaced. The characteristics of the fuse must be checked against the motor data before using the module. The protection circuit in the module allows a very simple protection of the motor cables. The fuse for the cable protection is a slow-blow one; without short circuit the robust behavior of the module remains.
The motor module is designed to supply the 24 V directly to the motor. At high currents or surges as they occur for example at braking, the module will not be damaged. The cable protection should be realized outside the motor module with additional measures. | no | ||||||||||||||||||||
Flat design, installation in cable duct possible
Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation. | yes, depth: 35 mm | ||||||||||||||||||||
Inputs digital | 4 | ||||||||||||||||||||
Outputs digital | 3 x electronic | ||||||||||||||||||||
Outputs analog | - | ||||||||||||||||||||
Input voltage (sensor supply)
inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | out of ASi | ||||||||||||||||||||
Output voltage (actuator supply)
Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential. For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | out of ASi | ||||||||||||||||||||
Connection
PUR line, oil resistant. Further connection options are available on request.
| 1 x M12 cable socket, straight, 8 poles + 2 x M12 cable socket, straight, 5 poles | ||||||||||||||||||||
Round cable
Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled. In the case of the active distributors (ASi slaves) however only the one ASi profile cable is counted. | 2 m | ||||||||||||||||||||
ASi connection
The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| ASi profile cable | ||||||||||||||||||||
ASi address
AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | 1 AB Slave |
General information
Commissioning
Manuals
EPLAN Macros
Video Tutorial