Notice
Please log in in order to have access to this file.
Please log in in order to shop in our webshop.
Logo Bihl+Wiedemann GmbH
Home | Sitemap | News | Licensing | Login  
 
 

I/O Modules

Bihl+Wiedemann offers a wide variety of AS-i modules. These are equipped with a various number of in- and outputs offering the right module for any application. Nor are special requirements a problem, such as sensors powered from AS-i or external voltage (AUX). The large selection of analog modules reflects the commitment to offering the right module for any application or analog signal. Deserving special mention are high-resolution 16-bit analog modules or modules for especially fast transmission of the analog values.

 

Product selector

System description

Content overview

Digital Modules AS-i: IP20, 22,5 mm

  • Cost efficient solution in IP20, 22,5 mm
Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital, EDM

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

Output voltage (actuator supply)

the connection to AS-i as well to AUX (auxiliary 24 V power) is made via yellow resp. black AS-i profile cable with piercing technology or via M12 socket (in IP20 via clamps).

AS-i connection

AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific AS-i Slave profiles.

AS-i address
Article No.
BWU2783 IP20, 22,5 mm x 50 mm, 4 x COMBICON 4 x COMBICON IP20 4 4 x electronic out of AS-i out of AS-i clamps 1 AB Slave BWU2783
BWU2723 IP20, 22,5 mm x 114 mm, 4 x COMBICON 3 x COMBICON IP20 4 - out of AUX - clamps 1 AB Slave BWU2723
BWU1938 IP20, 22,5 mm x 114 mm, 4 x COMBICON 4 x COMBICON IP20 4 4 x electronic out of AUX out of AUX clamps 1 AB Slave BWU1938
BWU2759 IP20, 22,5 mm x 114 mm, 4 x COMBICON 4 x COMBICON IP20 4 4 x electronic out of AUX out of AUX clamps 1 Single Slave BWU2759
BWU2721 IP20, 22,5 mm x 114 mm, 4 x COMBICON 4 x COMBICON IP20 8 - out of AUX - clamps 2 AB Slaves BWU2721
BWU2490 IP20, 22,5 mm x 114 mm, 6 x COMBICON 6 x COMBICON IP20 8 8 x electronic out of AUX out of AUX clamps 2 AB Slaves BWU2490
BWU2800 IP20, 22,5 mm x 114 mm, 6 x COMBICON 6 x COMBICON IP20 8 8 x electronic out of AUX out of AUX clamps 2 Single Slaves BWU2800
Content overview

Digital Modules AS-i in Stainless Steel, IP20

  • Robust, Stainless Steel in IP20
Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital, EDM

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

Output voltage (actuator supply)

the connection to AS-i as well to AUX (auxiliary 24 V power) is made via yellow resp. black AS-i profile cable with piercing technology or via M12 socket (in IP20 via clamps).

AS-i connection

AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific AS-i Slave profiles.

AS-i address
Article No.
BW1926 Stainless Steel in IP20, depth: 45 mm depth: 45 mm IP20 4 4 x relay out of AS-i out of AS-i clamps 1 Single Slave BW1926
BW1808 Stainless Steel in IP20, depth: 45 mm depth: 45 mm IP20 4 3 x relay out of AS-i out of AS-i clamps 1 AB Slave BW1808
BW1907 Stainless Steel in IP20, depth: 45 mm depth: 45 mm IP20 4 4 x electronic out of AUX out of AUX clamps 1 AB Slave BW1907
BW2565 Stainless Steel in IP20, depth: 45 mm depth: 45 mm IP20 4 4 x electronic out of AUX out of AUX clamps 1 Single Slave BW2565
BW2077 Stainless Steel in IP20, depth: 45 mm depth: 45 mm IP20 8 - out of AUX - clamps 2 AB Slaves BW2077
BW2078 Stainless Steel in IP20, depth: 45 mm depth: 45 mm IP20 - 8 x electronic - out of AUX clamps 2 AB Slaves BW2078
BW2555 Stainless Steel in IP20, depth: 90 mm depth: 90 mm IP20 4 4 x relay out of AS-i out of AS-i clamps 1 Single Slave BW2555
BW2556 Stainless Steel in IP20, depth: 90 mm depth: 90 mm IP20 8 - out of AUX - clamps 2 AB Slaves BW2556
Content overview

Digital Modules AS-i, IP67, M12

  • IP67, M12: 2 x 2 connectors for profile cable
  • 2color LEDs per output, state yellow, overload red
Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital, EDM Inputs analog

either as a single–wiring, Y–wiring or mixed-wiring.

Single-wiringY-wiringMixed-wiring



M12 wiring

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

Output voltage (actuator supply)

the connection to AS-i as well to AUX (auxiliary 24 V power) is made via yellow resp. black AS-i profile cable with piercing technology or via M12 socket (in IP20 via clamps).

AS-i connection

AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific AS-i Slave profiles.

AS-i address
Article No.
BWU3141 IP67, 4 x M12 4 x M12 IP67 2 2 x electronic - Single out of AS-i out of AUX AS-i profile cable 1 AB Slave BWU3141
BWU2552 IP67, 4 x M12 4 x M12 IP67 4 - - Y out of AS-i - AS-i profile cable 1 AB Slave BWU2552
BWU3077 IP67, 4 x M12 4 x M12 IP67 4 - - Y out of AS-i - AS-i using M12 1 AB Slave BWU3077
BWU2620 IP67, 4 x M12 4 x M12 IP67 4 - - Single out of AS-i - AS-i profile cable 1 AB Slave BWU2620
BWU2725 IP67, 4 x M12 4 x M12 IP67 4 - - Single out of AUX - AS-i profile cable 1 AB Slave BWU2725
BWU2767 IP67, 4 x M12 4 x M12 IP67 4 2 x electronic - Mixed out of AUX out of AUX AS-i profile cable 1 AB Slave BWU2767
BWU2487 IP67, 4 x M12 4 x M12 IP67 4 4 x electronic - Y out of AS-i out of AUX AS-i profile cable 1 AB Slave BWU2487
BWU3032 IP67, 4 x M12 4 x M12 IP67 4 4 x electronic - Y out of AUX out of AUX AS-i profile cable 1 AB Slave BWU3032
BWU2547 IP67, 4 x M12 4 x M12 IP67 4 4 x electronic - Mixed out of AUX out of AUX AS-i profile cable 1 AB Slave BWU2547
BWU3240 IP67, 4 x M12 4 x M12 IP67 4 4 x electronic - Mixed out of AS-i out of AS-i AS-i profile cable 1 AB Slave BWU3240
BWU2713 IP67, 4 x M12 4 x M12 IP67 - 4 x electronic - Y - out of AUX AS-i profile cable 1 Single Slave BWU2713
BWU2594 IP67, 4 x M12 4 x M12 IP67 - 4 x electronic - Y - out of AUX AS-i profile cable 1 AB Slave BWU2594
BWU2728 IP67, 4 x M12 4 x M12 IP67 - 4 x electronic - Y - out of AUX, 2 A per output AS-i profile cable 1 AB Slave BWU2728
BWU2626 IP67, 8 x M12 8 x M12 IP67 4 4 x electronic - Y out of AS-i out of AUX AS-i profile cable 1 AB Slave BWU2626
BWU2617 IP67, 8 x M12 8 x M12 IP67 4 4 x electronic - Single out of AS-i out of AUX AS-i profile cable 1 AB Slave BWU2617
BWU2684 IP67, 8 x M12 8 x M12 IP67 4 4 x electronic - Single out of AS-i out of AUX AS-i profile cable 1 Single Slave BWU2684
BWU2810 IP67, 8 x M12 8 x M12 IP67 4 4 x electronic - Single out of AUX out of AUX AS-i profile cable 1 AB Slave BWU2810
BWU2645 IP67, 8 x M12 8 x M12 IP67 4 4 x electronic - Single out of AUX out of AUX AS-i using M12 1 AB Slave BWU2645
BWU2853 IP67, 8 x M12 8 x M12 IP67 4 x IO-Link Port + 4 x elektronic 4 x IO-Link Port - IO-Link Port Class A out of AUX out of AUX AS-i profile cable 2 Single Slaves BWU2853
BWU3020 IP67, 8 x M12 8 x M12 IP67 4 x IO-Link Port 4 x IO-Link Port - IO-Link Port Class B out of AS-i output voltage out of AS-i, actuator supply out of AUX AS-i profile cable 2 Single Slaves BWU3020
BWU2770 IP67, 8 x M12 8 x M12 IP67 8 - - Y out of AUX - AS-i profile cable 2 AB Slaves BWU2770
BWU2651 IP67, 8 x M12 8 x M12 IP67 8 - - Y out of AS-i - AS-i profile cable 2 AB Slaves BWU2651
BWU2983 IP67, 8 x M12 8 x M12 IP67 8 - - Single out of AS-i - AS-i profile cable 2 AB Slaves BWU2983
BWU2619 IP67, 8 x M12 8 x M12 IP67 8 8 x electronic - Y out of AS-i out of AUX AS-i profile cable 2 AB Slaves BWU2619
BWU2652 IP67, 8 x M12 8 x M12 IP67 - 8 x electronic - Y - out of AUX AS-i profile cable 2 AB Slaves BWU2652
BWU2313 IP67, 8 x M12 8 x M12 IP67 4 4 x electronic 2 x Pt100 Signal at pin2/pin4 out of AUX out of AUX AS-i profile cable 2 AB Slaves BWU2313

 

An AS-Interface installation with IP67 digital modules from Bihl+Wiedemann having M12 plug-in connections offers many advantages: There are 2 x 2 connections for the yellow profile cable in the substructure of the module. These enable an clearly organized AS-i installation where up to 4 AS-i end caps and 2 passive distributors per module can be saved.

(Click to enlarge): AS-i Installation with modules from Bihl+Wiedemann (Click to enlarge): AS-i Installation with traditional modules

 

 

 

 

 

Content overview

Analog Modules AS-i: IP20, 22,5 mm

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs analog Outputs analog

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

Output voltage (actuator supply)

the connection to AS-i as well to AUX (auxiliary 24 V power) is made via yellow resp. black AS-i profile cable with piercing technology or via M12 socket (in IP20 via clamps).

AS-i connection

AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific AS-i Slave profiles.

AS-i address
Article No.
BWU1897 IP20, 22,5 mm x 92 mm 4 x COMBICON IP20 2 x 4 ... 20 mA/2 x 0 … 10 V - selectable, out of AS-i or out of AUX, Default out of AS-i - clamps 1 AB Slave BWU1897
BWU1345 IP20, 22,5 mm x 92 mm 4 x COMBICON IP20 2 x 4 ... 20 mA/2 x 0 … 10 V - selectable, out of AS-i or out of AUX, Default out of AS-i - clamps 1 Single Slave BWU1345
BWU1412 IP20, 22,5 mm x 92 mm 4 x COMBICON IP20 - 2 x 0 … 20 mA/2 x 0 …10 V - selectable, out of AS-i or out of AUX, default out of AS-i clamps 1 Single Slave BWU1412
BWU1727 IP20, 22,5 mm x 92 mm 4 x COMBICON IP20 - 2 x 0 … 20 mA/2 x 0 …10 V - selectable, out of AS-i or out of AUX, default out of AUX clamps 1 Single Slave BWU1727
BWU2224 IP20, 22,5 mm x 92 mm 4 x COMBICON IP20 - 2 x +-10 V - out of AUX clamps 1 Single Slave BWU2224
BWU1364 IP20, 22,5 mm x 105 mm 6 x COMBICON IP20 4 x 4 … 20 mA - out of AS-i or out of AUX, auto switching - clamps 1 Single Slave BWU1364
BWU1365 IP20, 22,5 mm x 105 mm 6 x COMBICON IP20 4 x 0 ... 10 V - out of AS-i or out of AUX, auto switching - clamps 1 Single Slave BWU1365
BWU1368 IP20, 22,5 mm x 105 mm 6 x COMBICON IP20 4 x Pt100 - out of AS-i - clamps 1 Single Slave BWU1368
BWU1933 IP20, 22,5 mm x 105 mm 6 x COMBICON IP20 4 x thermocouple type J - out of AS-i - clamps 1 Single Slave BWU1933
BWU2243 IP20, 22,5 mm x 105 mm 6 x COMBICON IP20 4 x thermocouple type K - out of AS-i - clamps 1 Single Slave BWU2243
BWU1366 IP20, 22,5 mm x 105 mm 6 x COMBICON IP20 - 4 x 0 … 20 mA - out of AS-i or out of AUX, auto switching clamps 1 Single Slave BWU1366
BWU1367 IP20, 22,5 mm x 105 mm 6 x COMBICON IP20 - 4 x 0 ... 10 V - out of AS-i or out of AUX, auto switching clamps 1 Single Slave BWU1367
Content overview

Analog Modules AS-i: IP65, PG

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs analog Outputs analog

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

Output voltage (actuator supply)

the connection to AS-i as well to AUX (auxiliary 24 V power) is made via yellow resp. black AS-i profile cable with piercing technology or via M12 socket (in IP20 via clamps).

AS-i connection

AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific AS-i Slave profiles.

AS-i address
Article No.
BWU1232 IP65, 3 x PG 3 x PG IP65 2 x 4 … 20 mA - selectable, out of AS-i or out of AUX, Default out of AS-i - AS-i profile cable 1 Single Slave BWU1232
BWU1233 IP65, 3 x PG 3 x PG IP65 2 x 0 … 10 V - selectable, out of AS-i or out of AUX, Default out of AS-i - AS-i profile cable 1 Single Slave BWU1233
BWU2240 IP65, 3 x PG 3 x PG IP65 Load cell - out of AS-i - AS-i profile cable 1 Single Slave BWU2240
BWU1234 IP65, 3 x PG 3 x PG IP65 - 2 x 0 ... 20 mA - selectable, out of AS-i or out of AUX, default out of AS-i AS-i profile cable 1 Single Slave BWU1234
BWU1235 IP65, 3 x PG 3 x PG IP65 - 2 x 0 … 10 V - selectable, out of AS-i or out of AUX, default out of AS-i AS-i profile cable 1 Single Slave BWU1235
BWU1254 IP65, 8 x PG 8 x PG IP65 4 x Pt100 - out of AS-i - AS-i profile cable 1 Single Slave BWU1254
BWU1509 IP65, 8 x PG 8 x PG IP65 4 x Pt1000 - out of AS-i - AS-i profile cable 1 Single Slave BWU1509
Content overview

Analog Modules AS-i: IP65/IP67, M12

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs analog Outputs analog

either as a single–wiring, Y–wiring or mixed-wiring.

Single-wiringY-wiringMixed-wiring



M12 wiring

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

Output voltage (actuator supply)

the connection to AS-i as well to AUX (auxiliary 24 V power) is made via yellow resp. black AS-i profile cable with piercing technology or via M12 socket (in IP20 via clamps).

AS-i connection

AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific AS-i Slave profiles.

AS-i address
Article No.
BWU3100 IP67, 4 x M12 4 x M12 IP67 2 x 4 … 20 mA - Signal at pin2/pin4 out of AS-i - AS-i profile cable 1 AB Slave BWU3100
BWU3104 IP67, 4 x M12 4 x M12 IP67 2 x Pt100 - Signal at pin1/pin3 out of AS-i - AS-i profile cable 1 AB Slave BWU3104
BWU3105 IP67, 4 x M12 4 x M12 IP67 - 2 x 0 ... 20 mA Signal at pin1/pin3 - out of AUX AS-i profile cable 1 Single Slave BWU3105
BWU3106 IP67, 4 x M12 4 x M12 IP67 - 2 x 0 ... 20 mA Signal at pin2/pin4 - out of AUX AS-i profile cable 1 Single Slave BWU3106
BWU1893 IP65, M12, width: 45 mm width: 45 mm IP65 2 x 4 … 20 mA - Signal at pin2/pin4 out of AS-i - AS-i profile cable 1 AB Slave BWU1893
BWU1894 IP65, M12, width: 45 mm width: 45 mm IP65 2 x 4 … 20 mA - Signal at pin2/pin4 out of AS-i - AS-i profile cable 1 Single Slave BWU1894
BWU1963 IP65, M12, width: 45 mm width: 45 mm IP65 2 x 0 … 10 V - Signal at pin2/pin4 out of AS-i - AS-i profile cable 1 AB Slave BWU1963
BWU1964 IP65, M12, width: 45 mm width: 45 mm IP65 2 x 0 … 10 V - Signal at pin2/pin4 out of AS-i - AS-i profile cable 1 Single Slave BWU1964
BWU1895 IP65, M12, width: 45 mm width: 45 mm IP65 2 x Pt100 - Signal at pin2/pin4 out of AS-i - AS-i profile cable 1 AB Slave BWU1895
BWU1917 IP65, M12, width: 90 mm width: 90 mm IP65 1 x 4 … 20 mA/0 … 10 V 1x 0 … 20 mA Signal In at pin1/pin3, signal Out at pin2/pin4 out of AS-i out of AS-i AS-i profile cable 2-4 Single Slaves BWU1917
BWU1853 IP65, M12, width: 90 mm width: 90 mm IP65 1 x 4 … 20 mA/0 … 10 V 1x 0 … 10 V Signal In at pin1/pin3, signal Out at pin2/pin4 out of AUX out of AUX AS-i profile cable 2-4 Single Slaves BWU1853
BWU1359 IP65, M12, width: 90 mm width: 90 mm IP65 4 x 4 … 20 mA - Signal at pin2/pin4 out of AS-i or out of AUX, auto switching - AS-i profile cable 1 Single Slave BWU1359
BWU1360 IP65, M12, width: 90 mm width: 90 mm IP65 4 x 0 ... 10 V - Signal at pin2/pin4 out of AS-i or out of AUX, auto switching - AS-i profile cable 1 Single Slave BWU1360
BWU1363 IP65, M12, width: 90 mm width: 90 mm IP65 4 x Pt100, 2/4 wire mode - Signal at pin2/pin4 out of AS-i - AS-i profile cable 1 Single Slave BWU1363
BWU2532 IP65, M12, width: 90 mm width: 90 mm IP65 4 x Pt100, 2/3 wire mode - Signal at pin2/pin4 out of AS-i - AS-i profile cable 1 Single Slave BWU2532
BWU1722 IP65, M12, width: 90 mm width: 90 mm IP65 - 4 x 0 … 20 mA Signal at pin1/pin3 - out of AUX AS-i profile cable 1 Single Slave BWU1722
BWU1361 IP65, M12, width: 90 mm width: 90 mm IP65 - 4 x 0 … 20 mA Signal at pin1/pin3 - out of AS-i or out of AUX, auto switching AS-i profile cable 1 Single Slave BWU1361
BWU1362 IP65, M12, width: 90 mm width: 90 mm IP65 - 4 x 0 ... 10 V Signal at pin1/pin3 - out of AS-i or out of AUX, auto switching AS-i profile cable 1 Single Slave BWU1362
BWU2857 IP65, M12, width: 90 mm width: 90 mm IP65 - 4 x 0 … 10 V; 24 V, 0 V via M12 Signal at pin1/pin3 - out of AS-i or out of AUX, auto switching AS-i profile cable 1 Single Slave BWU2857
BWU2313 IP67, 8 x M12 8 x M12 IP67 2 x Pt100 - Signal at pin2/pin4 out of AUX out of AUX AS-i profile cable 2 AB Slaves BWU2313

Replacement, AS-i version 2.0

Single Slaves work even with the first AS-i Masters.

Keywords for this page: AS-i digital modules, AS-i analog modules, I/O modules, IO modules, IP20, IP67, Circuit board modules AS-i circuit board modules, PCB solutions, potted, unpotted, I/O Link, IO Link