Logo Bihl+Wiedemann GmbH

Safety Monitor

Additional attributes:

Figure
Type
Model
Protection rating
Inputs Safety, SIL 3, Cat. 4
Inputs digital, EDM
Inputs safety, expandable to
Outputs Safety, SIL 3, cat. 4
Safety outputs, independent according to SIL 3, expandable to
Safety communication
Fieldbus interface
Number of AS-i networks, number of AS-i Master
1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies
Diagnostic and configuration interface
Recognition of duplicate AS-i addresses
AS-i fault detector
Programming in C
Article No.
Safety Basic Monitor
Safety Basic Monitor with extended features
IP20
4 x 2 channels, inputs 3+4, compatible as replacement with consortial monitor
8
max. 31 x 2 channels
2 release circuits; 2 x fast electronic safe outputs
max. 8
-
AS-i monitors
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
USB
no
no
no
Safety Basic Monitor
Safety Basic Monitor with extended features
IP20
4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
8
max. 31 x 2 channels
2 release circuits; 2 x fast electronic safe outputs
max. 8
-
Signaling contacts
1 AS-i network, 1 AS-i Master
yes, max. 0,5 A/AS-i network, max. 8 A with AS-i power supply
USB
no
no
no
Safety Basic Monitor
Safety Basic Monitor with extended features
IP20
3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz)
6
max. 31 x 2 channels, max. 1891 in max. configuration
2 release circuits; 2 x fast electronic safe outputs
max. 8, max. 991 in max. configuration
Safe Link
Signaling contacts
1 AS-i network, 1 AS-i Master
yes, max. 0,5 A/AS-i network, max. 8 A with AS-i power supply
Ethernet diagnostic + Modbus TCP diagnostic
no
no
no
Starter Kits
Safety Basic Monitor with extended features
IP20
4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
8
max. 31 x 2 channels
2 release circuits; 2 x fast electronic safe outputs
max. 8
-
Signaling contacts
1 AS-i network, 1 AS-i Master
yes, max. 0,5 A/AS-i network, max. 8 A with AS-i power supply
USB
no
no
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
no
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
2 release circuits; 2 x 2 relay
max. 16
-
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
no
Starter Kits
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFINET
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
Starter Kits
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Starter Kits
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels
6 release circuits; 6 x fast electronic safe outputs
max. 31
PROFIsafe (F-CPU) + ASIMON program
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON program
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON program
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
-
-
max. 31 x 2 channels
-
max. 16
PROFIsafe (F-CPU)
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
RS 232
yes
yes
no
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 64, max. 1984 in max. configuration
PROFIsafe (F-CPU) + ASIMON program + Safe Link
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels
6 release circuits; 6 x fast electronic safe outputs
max. 31
PROFIsafe (F-CPU) + ASIMON program
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
-
-
max. 62 x 2 channels
-
max. 16
PROFIsafe (F-CPU) + ASIMON program
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON program
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
Safety, Sercos
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 64, max. 1984 in max. configuration
CIP Safety over Sercos + Safe Link
Sercos
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, Sercos
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 64, max. 1984 in max. configuration
safe Schneider drives over Sercos + Safe Link
Sercos
2 AS-i networks, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, Sercos
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Sercos
2 AS-i networks, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels
6 release circuits; 6 x fast electronic safe outputs
max. 64
CIP Safety over EtherNet/IP
EtherNet/IP + ModbusTCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherNet/IP + ModbusTCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherNet/IP + ModbusTCP
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
EtherNet/IP + ModbusTCP
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
-
4
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherNet/IP + ModbusTCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
Safety, DeviceNet
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
DeviceNet
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 64, max. 1984 in max. configuration
FSoE + Safe Link
EtherCAT
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
EtherCAT
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
FSoE + Safe Link
EtherCAT
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
EtherCAT
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, POWERLINK
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
POWERLINK
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, POWERLINK
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
POWERLINK
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, CANopen
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
CANopen
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety, CC-Link
Gateway with integrated Safety Monitor
IP20
3 x 2 channels
6
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
CC-Link
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
Safety Monitor in Stainless Steel
Safety Monitor in Stainless Steel
IP20
-
4
max. 62 x 2 channels
2 release circuits; 2 x 2 relay
max. 16
-
AS-i Safety Monitors
2 AS-i networks, no AS-i Master, AS-i Monitor
no, max. 8 A/AS-i network, redundant supply
Ethernet diagnostic
yes
yes
no
Safety Monitor in Stainless Steel
Safety Monitor in Stainless Steel
IP20
-
4
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
AS-i Safety Monitors
2 AS-i networks, no AS-i Master, AS-i Monitor
no, max. 8 A/AS-i network, redundant supply
RS 232
yes
yes
no