Logo Bihl+Wiedemann GmbH

Speed Monitors

Additional attributes:

Figure
Type
Model
Protection rating
Safe Monitoring
Encoder signal/Sensor signal
Number of monitored axes
Inputs Safety, SIL 3, Cat. 4
Outputs Safety, SIL 3, cat. 4
Encoder/Sensor connection
Diagnostic and configuration interface
AS-i connection
AS-i address
Article No.
Speed Monitor Standalone*
Speed Monitor for encoders
IP20
speed + position
sine/cosine, TTL, SSI
up to 2 independent axes
-
2 release circuits; 2 x fast electronic safe outputs
RJ45
USB
-
-
Speed Monitor Standalone*
Speed Monitor for encoders
IP20
speed + position
sine/cosine, TTL
1 axis
-
2 release circuits; 2 x fast electronic safe outputs
RJ45
USB
-
-
Speed Monitor Modular
Speed Monitor for encoders
IP20
speed + position
sine/cosine, TTL, SSI
up to 2 independent axes
-
2 release circuits; 2 x fast electronic safe outputs
RJ45
via AS-i
clamps
depending on configuration
Speed Monitor Modular
Speed Monitor for encoders
IP20
speed + position
sine/cosine, TTL
1 axis
-
2 release circuits; 2 x fast electronic safe outputs
RJ45
via AS-i
clamps
depending on configuration
Speed Monitor Modular
Speed Monitor for encoders
IP20
speed
sine/cosine, SSI
up to 2 independent axes
-
-
Mini IO
via AS-i
clamps
depending on configuration
Speed Monitor Modular
Speed Monitor for encoders
IP20
speed
HTL or sensors/initiators (24V)
up to 2 independent axes
-
-
Mini IO
via AS-i
clamps
depending on configuration
Safety Basic Monitor
Safety Basic Monitor with extended features
IP20
speed
sensors/initiators (24V)
up to 2 independent axes
3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz)
2 release circuits; 2 x fast electronic safe outputs
clamps
Ethernet diagnostic + Modbus TCP diagnostic
clamps
-
Safety Basic Monitor
Safety Basic Monitor with extended features
IP20
speed
sensors/initiators (24V)
up to 4 independent axes
4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
2 release circuits; 2 x fast electronic safe outputs
clamps
USB
clamps
-
Safety, Sercos
Gateway with integrated Safety Monitor
IP20
depending on drive
depending on drive
up to 22 independant axes
3 x 2 channels
6 release circuits; 6 x fast electronic safe outputs
clamps
Ethernet diagnostic
clamps
-

*Currently not available, please contact us.