Logo Bihl+Wiedemann GmbH

Speed Monitors

BWU3160ASi-3 CIP Safety over Sercos Gateway with integrated Safety Monitor, 2 ASi masters

Product description

ASi-3 CIP Safety over Sercos Gateway with integrated Safety Monitor, 2 ASi masters, 1 power supply for 2 ASi networks, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels safe inputs, 1922 x 2 channels safe inputs in max. configuration, 6 release circuits (6 x electronic safe outputs), expandable to max. 64 safe outputs, 1984 safe outputs in max. configuration, CIP Safety via Sercos and Safe Link, diagnostic and configuration via Ethernet diagnostic interface, duplicate address recognition, ASi fault detector, programming in C optional, IP20

Safely control and monitor safety drives with CIP Safety over Sercos

Technical data

Type Safety, Sercos
Model Gateway with integrated Safety Monitor
Protection rating

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

IP20
Safe Monitoring depending on drive
Encoder signal/Sensor signal depending on drive
Number of monitored axes up to 22 independant axes
Inputs Safety, SIL 3, Cat. 4 3 x 2 channels
Outputs Safety, SIL 3, cat. 4 6 release circuits; 6 x electronic safe outputs
Encoder/Sensor connection clamps
Diagnostic and configuration interface

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Ethernet diagnostic
ASi connection

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

clamps
ASi address

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

-

Manuals

    Device Description Files (GSD, EDS, ESI, SDD, etc.)

    The product has earned the following certifications: