Building Automation

The benefits of AS-Interface – such as the simple, cost-saving installation and high degree of flexibility – have now established themselves in building automation. Numerous companies are already using the ASi installation system, for example for controlling fire and smoke dampers, shutter drives or heating and cooling ceilings using analog output modules. Damper drives with flow regulators can be connected to the controller through the MP-Bus gateway. It is also possible to process EnOcean signals from wireless pushbuttons and sensors over ASi. During your planning and application implementation phases we can be at your side and are open to application-specific special solutions.

 

ASi Gateways in Stainless Steel

  • BACnet/IP
  • PROFINET
  • PROFIBUS
  • Modbus RTU
  • EtherNet/IP + Modbus TCP
Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IP+ Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU4258
EtherNet/IP + Modbus TCP ASi-5/ASi-3
Gateway
IP20
EtherNet/IP, Modbus/TCP, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 8 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
BWU4019
EtherNet/IP + Modbus TCP ASi-5/ASi-3
Gateway
IP20
EtherNet/IP, Modbus/TCP, OPC UA
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 8 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
BWU4778
BACnet/IP ASi
Gateway
IP20
BACnet/IP, OPC UA
2 ASi networks, 2 ASi-3 Masters
yes, max. 8 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
BWU3356
BACnet/IP ASi
Gateway
IP20
BACnet/IP, OPC UA
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
BWU3735
EtherNet/IP + ModbusTCP ASi
Gateway
IP20
EtherNet/IP, Modbus/TCP, OPC UA
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus
yes
yes
optional
BWU3734
EtherNet/IP + ModbusTCP ASi
Gateway
IP20
EtherNet/IP, Modbus/TCP, OPC UA
1 ASi network, 1 ASi-3 Master
no, max. 8 A/ASi network
Ethernet fieldbus
yes
yes
optional
BWU1642
RS 485 Modbus ASi
Gateway
IP20
Modbus/RTU; RS 485
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
RS 232
yes
yes
no
BWU1641
RS 485 Modbus ASi
Gateway
IP20
Modbus/RTU; RS 485
1 ASi network, 1 ASi-3 Master
no, max. 8 A/ASi network
RS 232
yes
yes
no
BWU2239
PROFINET ASi
Gateway
IP20
PROFINET
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
optional
BWU2545
PROFIBUS ASi
Gateway
IP20
PROFIBUS
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet diagnostic
yes
yes
optional
BWU2544
PROFIBUS ASi
Gateway
IP20
PROFIBUS
1 ASi network, 1 ASi-3 Master
no, max. 8 A/ASi network
Ethernet diagnostic
yes
yes
optional

 

 

ASi Gateways with integrated Safety Monitor

  • BACnet/IP
Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation. Bihl+Wiedemann offers a wide range of gateways for common fieldbus interfaces:

 

  • PROFIBUS
  • PROFINET
  • EtherNet/IP+ Modbus TCP
  • BACnet/IP
  • DeviceNet
  • ControlLogix
  • Compact-/MicroLogix
  • EtherCat
  • POWERLINK
  • CC-Link
  • CANopen
  • RS 485 Modbus
  • OPC UA server

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

Access to ASi master and safety monitor via own software from Bihl+Wiedemann using the diagnostic interface (e.g. USB, RJ45, RS232). For certain devices with Ethernet-based fieldbus (PROFINET, EtherNet/IP), there is also the option of diagnostics and configuration directly via the fieldbus interface.

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM

Safe inputs can be configured as 1-channel or 2-channels depending on the desired application or PL and SIL level.

Inputs Safety, SIL 3, Cat. 4
Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU4780
Safety, BACnet/IP
Gateway with integrated Safety Monitor
IP20
BACnet/IP, OPC UA
2 ASi networks, 2 ASi-3 Masters
yes, max. 8 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 128 x 2 channels, max. 3968 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 128, max. 3968 in max. configuration
Safe Link
BWU4001
Safety, BACnet/IP
Gateway with integrated Safety Monitor
IP20
BACnet/IP, OPC UA
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 128 x 2 channels, max. 3968 in max. configuration
6 release circuits, 6 x electronic safe outputs
max. 128, max. 3968 in max. configuration
Safe Link

 

 

Power Supplies

Figure

"ASi power supply":

Special power supplies with integrated data decoupling unit for use in ASi-3 only networks. Suitable for all Bihl+Wiedemann ASi-3 gateways and safety monitors.

"30 V power supply":

Inexpensive standard power supplies, suitable as an alternative for use with ASi gateways and safety monitors with integrated data decoupling unit (version "1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi gateways.


30 V power supply, optimized for ASi-5/ASi-3:

Inexpensive standard power supplies, optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated data decoupling unit (version "1 power supply , 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.


30 V power supply, optimized for ASi-5/ASi-3, NEC class 2 :

The 30 V/3 A power supply is UL certified, has power limitation <100 W and is designed for use in NEC class 2 networks. It is suitable for applications with 1 power supply per ASi network. In the case of power intensive applications, Bihl+Wiedemann recommends the use of a 30 V power supply without 100 W power limitation in combination with a power limitation module (BWU4189) for each ASi network.The power supply is optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated decoupling coils (version "1 power supplies, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 V ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.


"ASi power supply decoupling unit":

Supply of 2 ASi networks out of 1 power supply. Applicable with double masters without integrated data decoupling.


"Power decoupling unit":

Take up to 1,2 A out of ASi. In combination with an ASi Repeater: decouples 1,2 A from ASi Segment B and supplies Segment A with 1,2 A.

Power supply
Input voltage Output current

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BW4221
30 V power supply, optimized for ASi-5/ASi-3
100 ... 240 VAC, 1 phase
16 A
IP20
BW4219
30 V power supply, optimized for ASi-5/ASi-3
100 ... 240 VAC, 1 phase
8 A
IP20
BW4218
30 V power supply, optimized for ASi-5/ASi-3
100 ... 240 VAC, 1 phase
4 A
IP20
BW1997
ASi power supply
115 VAC / 230 VAC, power supply with range switch
8 A
IP20
BW1649
ASi power supply
90 ... 265 VAC, wide range supply
4 A
IP20
BW2255
ASi power supply
115 ... 250 VAC
1,8 A
IP20

 

Fire damper "Stand alone" control unit

  • provided as a kit in rugged plastic housing, pre-wired for easy and fast installation
  • pre-installed user software,no further configuration needed
  • centralized control of damper drives and detection of damper positions
  • plain text display and spontaneous diagnostics directly via device display and function LEDs
  • automated testing of damper function via different test modes
Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Number of fire dampers Number of fire damper groups Number of building ventilation system releases Controlling ventilation, fire, smoke dampers Article No.
BW3545
110...240 VAC, 2 ASi circuits
Fire damper "Stand-Alone" control unit
polystyrol, 450/300/209
IP65
120 / 240
6
2, extensible
-
BW3547
110...240 VAC, 1 ASi circuit
Fire damper "Stand-Alone" control unit
polystyrol, 300/300/209
IP65
30 / 60
3
1, extensible
-
BW3550
Control program for fire damper "Stand alone" control unit
software
-
-
120 / 240
6
2, extensible
-

Fire/smoke dampers

  • Controlling ventilation, fire, smoke dampers
  • Requirements for Germany and EC
  • Requirements for Switzerland (IG-BSK)
  • 24V/230V relay
  • EN 6206 SIL2
Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BW2482
ventilation damper module
ventilation, fire, smoke dampers
-
IP54
4
2 x electronic
out of ASi
out of ASi
1 Single address
BW2028
ventilation damper module
ventilation, fire, smoke dampers
-
IP54
4
2 x electronic
out of ASi
out of ASi
1 Single address
BW2029
ventilation damper module
ventilation, fire, smoke dampers
-
IP54
3
2 x electronic
out of AUX
out of AUX
1 AB address
BW2080
ventilation damper module
ventilation, fire, smoke dampers
-
IP54
3
2 x electronic
out of ASi
out of ASi
1 AB address
BW3005
ventilation damper module, Safety
ventilation, fire, smoke dampers
-
IP40
4
2 x electronic
out of ASi
out of ASi
1 Single address
BW4917
ventilation damper module, Safety
ventilation, fire, smoke dampers
-
IP40
4
2 x electronic
out of ASi
out of ASi
1 Single address
BW3009
ventilation damper module
ventilation, fire, smoke dampers
-
IP54
4
4 x relay
out of ASi
-
1 AB address
BW3010
ventilation damper module
ventilation, fire, smoke dampers
-
IP54
4 + 2 x fusible link
2 x relay
out of ASi
-
1 AB address
BW3011
ventilation damper module
ventilation, fire, smoke dampers
-
IP54
4
2 x relay
out of ASi
-
1 AB address
BW2480
ventilation damper module
ventilation, fire, smoke dampers
surface-mounted box
IP54
4
-
out of ASi
-
1 AB address
BW3412
Surface-mounted box, IP54
I/O module
surface-mounted box
IP54
4
4 x electronic
out of AUX
out of AUX
1 AB address

 

Heating, Ventilating and Air Conditioning & Building Automation in General

  • Shutter modules
  • Heating/air conditioning
  • EnOcean
  • MP Bus
Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital Inputs analog Outputs analog

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)
Controlling heating/air conditioning Article No.
BW2114
shutter module
Shutter module
-
IP54
8
4 x relay
-
-
out of ASi
-
-
BW3944
shutter module
Shutter module
-
IP40
8
4 x relay
-
-
out of ASi
-
-
BW2701
Surface-mounted box, IP54
Analog module
surface-mounted box
IP54
-
-
1 x 0 ... 10 V
1x 0 … 10 V
selectable, out of ASi or out of AUX, Default out of ASi
selectable, out of ASi or out of AUX, default out of ASi
-
BW2536
heating/air conditioning (24 V AC/DC)
heating/air conditioning
surface-mounted box
IP54
-
2 x electronic
-
2 x 0 … 10 V
out of ASi
selectable, out of ASi or out of AUX (AC/DC), default out of ASi
Controlling heating and climate control ceilings
BW2537
heating/air conditioning (24 V AC/DC)
heating/air conditioning
surface-mounted box
IP54
2
-
2 x 0 ... 10 V
-
selectable, out of ASi or out of AUX (AC/DC), default out of ASi
-
Recording of analog values
BW2138
Heating/air conditioning
heating/air conditioning
surface-mounted box
IP54
-
4 x electronic
-
-
-
out of AUX
Controlling valves and heating valves
BW2128
PCB building automation
I/O module
OEM board
IP00
4
3 x electronic
-
-
out of AUX
out of AUX
-
BW2375
connection to EnOcean
connection to EnOcean
white
IP40
31 x 4
EnOcean
8 x 6
EnOcean
out of ASi
-
-
BW2473
connection to EnOcean
connection to EnOcean
black
IP40
31 x 4
EnOcean
8 x 6
EnOcean
out of ASi
-
-
BW2580
connection to EnOcean
connection to EnOcean
surface-mounted box
IP40
31 x 4
EnOcean
8 x 6
EnOcean
out of ASi
-
-
BW2406
connection to MP-Bus
connection to MP-Bus
-
IP54
-
-
-
-
out of ASi
out of AUX
-
BWU1232
IP65, 3 x PG
Analog module
3 x PG
IP65
-
-
2 x 4 … 20 mA
-
selectable, out of ASi or out of AUX, Default out of ASi
-
-
BWU1233
IP65, 3 x PG
Analog module
3 x PG
IP65
-
-
2 x 0 ... 10 V
-
selectable, out of ASi or out of AUX, Default out of ASi
-
-
BWU1234
IP65, 3 x PG
Analog module
3 x PG
IP65
-
-
-
2 x 0 ... 20 mA
-
selectable, out of ASi or out of AUX, default out of ASi
-
BWU1235
IP65, 3 x PG
Analog module
3 x PG
IP65
-
-
-
2 x 0 … 10 V
-
selectable, out of ASi or out of AUX, default out of ASi
-
BWU1254
IP65, 8 x PG
Analog module
8 x PG
IP65
-
-
4 x Pt100
-
out of ASi
-
-
BWU1509
IP65, 8 x PG
Analog module
8 x PG
IP65
-
-
4 x Pt1000
-
out of ASi
-
-
BWU1933
IP20, 25 mm x 105 mm, 6 x 4 contacts
Analog module
25.0 mm x 105.0 mm x 114.5 mm, 6 x 4 contacts
IP20
no digital inputs
no digital outputs
4 x thermocouple type J
no analog outputs
out of ASi
no output voltage
-
BWU2243
IP20, 25 mm x 105 mm, 6 x 4 contacts
Analog module
25.0 mm x 105.0 mm x 114.5 mm, 6 x 4 contacts
IP20
no digital inputs
no digital outputs
4 x thermocouple type K
no analog outputs
out of ASi
no output voltage
-
BW3779
PCB building automation
I/O module
Flush-mounted housing, thick coated
IP00, thick coated
4
4 x electronic
-
-
out of ASi
out of ASi
-
BW2388
PCB building automation
I/O module
Flush-mounted housing, thick coated
IP00, thick coated
4
-
-
-
out of ASi
-
-

 

Active Distributors ASi, IP67/IP20

Figure Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible

Display of the status of the inputs/outputs, ASi communication or peripheral errors and the status of the AUX supply according to the ASi specification.

LED status display
Connection

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

Round cable

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BWU3317
4
4 x electronic
out of ASi
out of AUX
yes, depth: 35 mm
yes
2 x round cables/connecting wires
1 m
1 AB address
BWU3326
4
4 x electronic
out of ASi
out of ASi
yes, depth: 35 mm
yes
2 x round cables/connecting wires
1 m
1 AB address
BW3300
no digital inputs
4 x electronic
no input voltage
out of AUX
yes, depth: 19 mm
yes
1 x round cable/connecting wires
1 m
1 AB address
BWU3349
4
no digital outputs
out of AUX
no output voltage
yes, depth: 19 mm
yes
8 x push in terminals
no
1 AB address
BWU3414
3
1 x electronic
out of AUX
out of AUX
yes, depth: 19 mm
yes
8 x push in terminals
no
1 AB address
BWU3342
no digital inputs
4 x electronic
no input voltage
out of AUX
yes, depth: 19 mm
yes
8 x push in terminals
no
1 AB address

 

 

I/O Modules for installation in control cabinets/decentralized control cabinets, IP20

  • Robust, Stainless Steel in IP20
  • Cost efficient solution in IP20, 22,5 mm
Figure Model Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BW1926
I/O module
4
4 x relay
out of ASi
-
1 Single address
BW1808
I/O module
4
3 x relay
out of ASi
-
1 AB address
BW1907
I/O module
4
4 x electronic
out of AUX
out of AUX
1 AB address
BWU2565
I/O module
4
4 x electronic
out of AUX
out of AUX
1 Single address
BWU2077
I/O module
8
-
out of AUX
-
2 AB addresses
BW2555
I/O module
4
4 x relay
out of ASi
-
1 Single address
BW2556
I/O module
8
-
out of AUX
-
2 AB addresses
BWU3874
I/O module
16
no digital outputs
out of AUX
no output voltage
1 ASi-5 address
BWU3873
I/O module
8
no digital outputs
out of AUX
no output voltage
1 ASi-5 address
BWU3872
I/O module
8
8 x electronic
out of AUX
out of AUX
1 ASi-5 address
BWU3842
I/O module
4
4 x electronic
out of AUX
out of AUX, 2 A per output
1 AB address
BWU3559
I/O module
4
4 x electronic
out of AUX
out of AUX
1 AB address
BWU2723
I/O module
4
no digital outputs
out of AUX
no output voltage
1 AB address
BWU1938
I/O module
4
4 x electronic
out of AUX
out of AUX
1 AB address
BWU2759
I/O module
4
4 x electronic
out of AUX
out of AUX
1 Single address
BWU2721
I/O module
8
no digital outputs
out of AUX
no output voltage
2 AB addresses
BWU3549
I/O module
4
4 x relay
out of ASi
no output voltage
1 AB address
BWU2490
I/O module
8
8 x electronic
out of AUX
out of AUX
2 AB addresses
BWU2800
I/O module
8
8 x electronic
out of AUX
out of AUX
2 Single addresses

 

 

I/O Modules for installation on ceiling, walls and floor, IP54

Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Bihl+Wiedemann offers modules with AB address, single address or ASi-5 address. In some cases, ASi modules can occupy several (different) addresses. Mixed operation of modules with different addressing in the same ASi circuit is permitted.
For ASi modules with two ASi-3 nodes, the second ASi-3 node is turned off as long as the first ASi-3 node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BW2139
Surface-mounted box, IP54
I/O module
surface-mounted box
IP54
4
3 x electronic
out of AUX
out of AUX
1 AB address
BW2137
Surface-mounted box, IP54
I/O module
surface-mounted box
IP54
4
4 x electronic
out of AUX
out of AUX
1 AB address
BW2175
Surface-mounted box, IP54
I/O module
surface-mounted box
IP54
4
4 x electronic
out of AUX
out of AUX
1 Single address

 

Passive Distributors ASi, IP67

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible
Connection

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

Round cable

The module has connections for ASi and/or AUX profile cables to supply data and (auxiliary) power. Depending on the design, the devices also have an integrated profile cable derivation.

Profile cable connection
Article No.
BW3186
Passive distributor ASi
depth: 19 mm
IP67
yes, depth: 19 mm
1 x round cable/connecting wires
0,25 m
2 x ASi
BW3524
Passive distributor ASi
depth: 19 mm
IP67
yes, depth: 19 mm
1 x round cable/connecting wires
5 m
2 x ASi
BW3803
Passive distributor ASi/AUX
depth: 28 mm
IP67
no
1 x M12 socket, 5 poles
no
1 x ASi, 1 x AUX 24 V
BWU3157
Passive distributor ASi
depth: 19 mm
IP67
yes, depth: 19 mm
profile cable branch
no
2 x ASi