Additional attributes:

    Figure
    Fieldbus interface
    Safety communication
    Inputs Safety, SIL 3, Cat. 4
    Outputs Safety, SIL 3, cat. 4
    ASi-5/ASi-3
    Number of ASi networks, number of ASi Master
    Integrated decoupling coils, ASi current measurement in the gateway
    Article No.
    ASi monitors
    -
    4 x 2 channels, inputs 3+4, compatible as replacement with consortial monitor
    2 release circuits, 2 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, no ASi Master, ASi Monitor
    no, max. 8 A/ASi network
    ASi monitors
    -
    4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
    2 release circuits, 2 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply
    ASi monitors
    Safe Link
    3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz)
    2 release circuits, 2 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply
    ASi monitors
    -
    4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
    2 release circuits, 2 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply
    PROFIBUS
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFIBUS
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    PROFIBUS
    PROFIsafe (F-CPU) + ASIMON program
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    PROFIsafe (F-CPU) + ASIMON program + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    PROFIsafe (F-CPU) + ASIMON program + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    PROFIsafe (F-CPU) + ASIMON program + Safe Link
    -
    -
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    PROFIsafe (F-CPU) + ASIMON program + Safe Link
    -
    -
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    Safe Link
    -
    -
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    Sercos, OPC UA
    safe Schneider drives over Sercos + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Sercos, OPC UA
    CIP Safety over Sercos + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Sercos, OPC UA
    CIP Safety over Sercos + Safe Link
    -
    -
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    EtherNet/IP + ModbusTCP, OPC UA
    CIP Safety over EtherNet/IP + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    EtherNet/IP + ModbusTCP, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    EtherNet/IP + ModbusTCP, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    EtherNet/IP + ModbusTCP
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    no, max. 8 A/ASi network, redundant supply
    BACnet/IP, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    no, max. 8 A/ASi network, redundant supply
    DeviceNet
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    EtherCAT, OPC UA
    FSoE + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    EtherCAT, OPC UA
    FSoE + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    EtherCAT, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    POWERLINK, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    POWERLINK
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    POWERLINK
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    CANopen
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    CC-Link
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network