Gateways with OPC UA from Bihl+Wiedemann

Using OPC UA in Bihl+Wiedemann Gateways you can release and then access your machine data as desired. The following data can be called up over your company network (examples):

  • I/O map for both ASi circuits and monitors
  • Device diagnostics
  • Fieldbus bits
  • Slave addressing
  • Safety diagnostics + Safe Link diagnostics
  • ASi EC flags and ASi fault detector
  • Safety at Work Monitor (max. 64 release circuits)

PROFINET, OPC UA

Figure Type Model

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix fieldbus

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway: interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.

 

 

 

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface
Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 Safety communication Article No.
BWU3852
PROFINET ASi-5/ASi-3
Gateway
PROFINET, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
-
-
-
BWU3848
PROFINET ASi-5/ASi-3
Gateway
PROFINET, OPC UA
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 8 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
-
-
-
BWU3847
24 Volt ASi-5/ASi-3 Gateway
Gateway
PROFINET, OPC UA
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet fieldbus
-
-
-
BWU3674
PROFIsafe, PROFINET, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
PROFINET, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
PROFIsafe (F-CPU) + Safe Link
BWU3862
PROFIsafe, PROFINET, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
PROFINET, OPC UA
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
PROFIsafe (F-CPU) + Safe Link
BWU4000
Safety, PROFINET ASi-5/ASi-3
Gateway with integrated Safety Monitor
PROFINET, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link
BWU3863
Safety, PROFINET ASi-5/ASi-3
Gateway with integrated Safety Monitor
PROFINET, OPC UA
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link
BWU3833
PROFIsafe, PROFINET, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
PROFINET, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
no local safe input
no local safe output
PROFIsafe (F-CPU) + Safe Link
BWU3998
Safety, PROFINET ASi-5/ASi-3
Gateway with integrated Safety Monitor
PROFINET, OPC UA
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
no local safe input
no local safe output
Safe Link

 

 

EtherNet/IP + ModbusTCP, OPC UA

Figure Type Model

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix fieldbus

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway: interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.

 

 

 

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface
Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 Safety communication Article No.
BWU3851
EtherNet/IP + Modbus TCP ASi-5/ASi-3
Gateway
EtherNet/IP + ModbusTCP, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
-
-
-
BWU3849
24 Volt ASi-5/ASi-3 Gateway
Gateway
EtherNet/IP + ModbusTCP, OPC UA
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet fieldbus
-
-
-
BWU3857
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
EtherNet/IP + ModbusTCP, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
CIP Safety over EtherNet/IP + Safe Link
BWU3825
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
EtherNet/IP + ModbusTCP, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link
BWU3866
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
Gateway with integrated Safety Monitor
EtherNet/IP + ModbusTCP, OPC UA
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet fieldbus + Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link

 

 

EtherCAT, OPC UA

Figure Type Model

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix fieldbus

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway: interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.

 

 

 

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface
Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 Safety communication Article No.
BWU3854
24 Volt ASi-5/ASi-3 Gateway
Gateway
EtherCAT, OPC UA
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
-
-
-
BWU3858
Safety, EtherCAT ASi-5/ASi-3
Gateway with integrated Safety Monitor
EtherCAT, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
FSoE + Safe Link
BWU3991
Safety, EtherCAT ASi-5/ASi-3
Gateway with integrated Safety Monitor
EtherCAT, OPC UA
1 ASi network, 1 ASi-5/ASi-3 Master
yes, max. 4 A/ASi network
Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
Safe Link

 

 

Sercos, OPC UA

Figure Type Model

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix fieldbus

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway: interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.

 

 

 

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface
Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 Safety communication Article No.
BWU3861
Safety, Sercos ASi-5/ASi-3
Gateway with integrated Safety Monitor
Sercos, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
safe Schneider drives over Sercos + Safe Link
BWU3860
Safety, Sercos ASi-5/ASi-3
Gateway with integrated Safety Monitor
Sercos, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
3 x 2 channels
6 release circuits, 6 x electronic safe outputs
CIP Safety over Sercos + Safe Link
BWU3845
Safety, Sercos ASi-5/ASi-3
Gateway with integrated Safety Monitor
Sercos, OPC UA
2 ASi networks, 2 ASi-5/ASi-3 Masters
yes, max. 4 A/ASi network
Ethernet diagnostic
no local safe input
no local safe output
CIP Safety over Sercos + Safe Link

 

 

BACnet/IP ASi

Figure Type Model

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix fieldbus

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway: interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.

 

 

 

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface
Outputs Safety, SIL 3, cat. 4 Inputs Safety, SIL 3, Cat. 4 Safety communication Article No.
BWU3356
BACnet/IP ASi
Gateway
BACnet/IP, OPC UA
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus + Ethernet diagnostic
-
-
-
BWU4001
Safety, BACnet/IP
Gateway with integrated Safety Monitor
BACnet/IP, OPC UA
2 ASi networks, 2 ASi-3 Masters
no, max. 8 A/ASi network, redundant supply
Ethernet fieldbus + Ethernet diagnostic
6 release circuits, 6 x electronic safe outputs
3 x 2 channels
Safe Link