Gateways with OPC UA from Bihl+Wiedemann
Using OPC UA in Bihl+Wiedemann Gateways you can release and then access your machine data as desired. The following data can be called up over your company network (examples):
- I/O map for both ASi circuits and monitors
- Device diagnostics
- Fieldbus bits
- Slave addressing
- Safety diagnostics + Safe Link diagnostics
- ASi EC flags and ASi fault detector
- Safety at Work Monitor (max. 64 release circuits)
PROFINET, OPC UA
Figure | Type | Model |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Inputs Safety, SIL 3, Cat. 4 | Outputs Safety, SIL 3, cat. 4 | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
![]() |
PROFINET ASi-5/ASi-3
|
Gateway
|
PROFINET, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
-
|
-
|
-
| BWU3852 ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 2 ASi-5/ASi-3 masters |
![]() |
PROFINET ASi-5/ASi-3
|
Gateway
|
PROFINET, OPC UA
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 8 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
-
|
-
|
-
| BWU3848 ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-5/ASi-3 master |
![]() |
24 Volt ASi-5/ASi-3 Gateway
|
Gateway
|
PROFINET, OPC UA
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus
|
-
|
-
|
-
| BWU3847 24 Volt ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-5/ASi-3 master |
![]() |
PROFIsafe, PROFINET, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
PROFINET, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
PROFIsafe (F-CPU) + Safe Link
| BWU3674 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() |
PROFIsafe, PROFINET, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
PROFINET, OPC UA
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
PROFIsafe (F-CPU) + Safe Link
| BWU3862 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
![]() |
Safety, PROFINET ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
PROFINET, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| BWU4000 ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() |
Safety, PROFINET ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
PROFINET, OPC UA
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| BWU3863 ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
![]() |
PROFIsafe, PROFINET, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
PROFINET, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
no local safe input
|
no local safe output
|
PROFIsafe (F-CPU) + Safe Link
| BWU3833 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 master |
![]() |
Safety, PROFINET ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
PROFINET, OPC UA
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
no local safe input
|
no local safe output
|
Safe Link
| BWU3998 ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
EtherNet/IP + ModbusTCP, OPC UA
Figure | Type | Model |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Inputs Safety, SIL 3, Cat. 4 | Outputs Safety, SIL 3, cat. 4 | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
![]() |
EtherNet/IP + Modbus TCP ASi-5/ASi-3
|
Gateway
|
EtherNet/IP + ModbusTCP, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
-
|
-
|
-
| BWU3851 ASi-5/ASi-3 EtherNet/IP+ModbusTCP Gateway in Stainless Steel, 2 ASi-5/ASi-3 masters |
![]() |
24 Volt ASi-5/ASi-3 Gateway
|
Gateway
|
EtherNet/IP + ModbusTCP, OPC UA
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus
|
-
|
-
|
-
| BWU3849 24 Volt ASi-5/ASi-3 EtherNet/IP + Modbus TCP Gateway in Stainless Steel, 1 ASi-5/ASi-3 master |
![]() |
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
EtherNet/IP + ModbusTCP, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
CIP Safety over EtherNet/IP + Safe Link
| BWU3857 ASi-5/ASi-3 CIP Safety over EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() |
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
EtherNet/IP + ModbusTCP, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| BWU3825 ASi-5/ASi-3 EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() |
Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
|
Gateway with integrated Safety Monitor
|
EtherNet/IP + ModbusTCP, OPC UA
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| BWU3866 ASi-5/ASi-3 EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
EtherCAT, OPC UA
Figure | Type | Model |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Inputs Safety, SIL 3, Cat. 4 | Outputs Safety, SIL 3, cat. 4 | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
![]() |
24 Volt ASi-5/ASi-3 Gateway
|
Gateway
|
EtherCAT, OPC UA
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
-
|
-
|
-
| BWU3854 24 Volt ASi-5/ASi-3 EtherCAT Gateway in Stainless Steel, 1 ASi-5/ASi-3 master |
![]() |
Safety, EtherCAT ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
EtherCAT, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
FSoE + Safe Link
| BWU3858 ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() |
Safety, EtherCAT ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
EtherCAT, OPC UA
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
Safe Link
| BWU3991 ASi-5/ASi-3 EtherCAT Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
Sercos, OPC UA
Figure | Type | Model |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Inputs Safety, SIL 3, Cat. 4 | Outputs Safety, SIL 3, cat. 4 | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
![]() |
Safety, Sercos ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
Sercos, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
safe Schneider drives over Sercos + Safe Link
| BWU3861 ASi-5/ASi-3 safe Schneider drives over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() |
Safety, Sercos ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
Sercos, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
CIP Safety over Sercos + Safe Link
| BWU3860 ASi-5/ASi-3 CIP Safety over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() |
Safety, Sercos ASi-5/ASi-3
|
Gateway with integrated Safety Monitor
|
Sercos, OPC UA
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
no local safe input
|
no local safe output
|
CIP Safety over Sercos + Safe Link
| BWU3845 ASi-5/ASi-3 CIP Safety over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
BACnet/IP ASi
Figure | Type | Model |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Outputs Safety, SIL 3, cat. 4 | Inputs Safety, SIL 3, Cat. 4 | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|
![]() |
BACnet/IP ASi
|
Gateway
|
BACnet/IP, OPC UA
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
Ethernet fieldbus + Ethernet diagnostic
|
-
|
-
|
-
| BWU3356 ASi-3 BACnet/IP Gateway in Stainless Steel, 2 masters |
![]() |
Safety, BACnet/IP
|
Gateway with integrated Safety Monitor
|
BACnet/IP, OPC UA
|
2 ASi networks, 2 ASi-3 Masters
|
no, max. 8 A/ASi network, redundant supply
|
Ethernet fieldbus + Ethernet diagnostic
|
6 release circuits, 6 x electronic safe outputs
|
3 x 2 channels
|
Safe Link
| BWU4001 ASi-3 BACnet/IP Gateway with integrated Safety Monitor, 2 ASi masters |