Schneider Electric

Bihl+Wiedemann is a member of Schneider Electric's "Technology Partner Program". In the following article overview you will find Bihl+Wiedemann products which can be used as replacement articles for Schneider Electric products. Since Schneider Electric no longer markets the products listed here themselves, you may source these replacement articles from us in the future. Here you can find further information.

Schneider Electric,Overview of equivalent products: Gateways in Stainless Steel

  • When using an equivalent Bihl+Wiedemann Gateway as a replacement for a Schneider Electric Gateway, the device description file must be reinstalled.
  • The latest version of the device description file (GSD, EDS, XDD etc.) of the gateway is available in the "Downloads" section of the respective device.
Schneider Electric Article No. Bihl+Wiedemann
Article No.
Figure
TCSAGPA1SF14FBWU1567
Bihl+Wiedemann Article No. BWU1567
TCSAGCA1SF14MBWU1821
Bihl+Wiedemann Article No. BWU1821
TCSAGEA1SF13FBWU1650
Bihl+Wiedemann Article No. BWU1650

Schneider Electric, Overview of equivalent products: Digital Modules ASi, IP67, M12

  • + Same number I/Os
  • + Same protection rating
  • + Same node profile
  • + Same required master profile
  • + Same dimensions/housing
  • + Same pin assignment (Pin5 = n.c.)
Schneider Electric Article No. Manufacturer Typ Inputs digital Outputs digital

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.

M8/M12 wiring

Die Anbindung an ASi und an AUX (24 V Hilfsenergie) erfolgt über das gelbe bzw. schwarze ASi Profilkabel mit Durchdringungstechnik oder über einen M12-Stecker (in IP20 über Klemmen).

 


Leitungsschutz: Wird das Modul über einen M12-Anschluss mit A- oder B-Codierung versorgt, darf es gem. IEC 61076-2-101 und IEC 61076-2-109 nur mit einer Strombelastung von max. 4 A pro Pin betrieben werden. Ein gesicherter Abgriff wird empfohlen. Für Module, die über Profilkabel und Durchdringungstechnik versorgt werden, gilt diese Einschränkung nicht.

ASi Anschluss
Required Master profile ASi node profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Bihl+Wiedemann
Article No.
Figure
ASI67FFP40DSchneider ElectricIP67, 4 x M124-standardASi Profilkabel≥M0S-0.0.F.E1 Single AdresseBWU3682
Bihl+Wiedemann Article No. BWU3682
Bihl+WiedemannIP67, 4 x M124-standardASi Profilkabel≥M0S-0.0.F.E1 Single Adresse
ASI67FFP43ESchneider ElectricIP67, 8 x M1243 x elektronischstandardASi Profilkabel≥M3S-7.A.(7).01 AB AdresseBWU3701
Bihl+Wiedemann Article No. BWU3701
Bihl+WiedemannIP67, 8 x M1243 x elektronischstandardASi Profilkabel≥M3S-7.A.(7).01 AB Adresse
ASI67FFP44DSchneider ElectricIP67, 8 x M1244 x elektronischstandardASi Profilkabel≥M0S-7.0.(F).E1 Single AdresseBWU3686
Bihl+Wiedemann Article No. BWU3686
Bihl+WiedemannIP67, 8 x M1244 x elektronischstandardASi Profilkabel≥M0S-7.0.(F).E1 Single Adresse (S-7.0.F.E)
ASI67FFP80EYSchneider ElectricIP67, 8 x M128-dual (Y)ASi Profilkabel≥M3S1-0.A.(7).2, S2-0.A.(7).22 AB AdressenBWU3523
Bihl+Wiedemann Article No. BWU3523
Bihl+WiedemannIP67, 8 x M128-dual (Y)ASi Profilkabel≥M3S1-0.A.(7).2, S2-0.A.(7).22 AB Adressen

Schneider Electric, Overview of functionally equivalent products: Digital Modules ASi, IP67, M12 - same node profile

  • + Same number I/Os
  • + Same protection rating
  • + Same node profile
  • + Same required master profile
  • + Same dimensions/housing
  • ‒ Different pin assignment
Schneider Electric Article No. Manufacturer Typ Inputs digital Outputs digital

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.

M8/M12 wiring

Die Anbindung an ASi und an AUX (24 V Hilfsenergie) erfolgt über das gelbe bzw. schwarze ASi Profilkabel mit Durchdringungstechnik oder über einen M12-Stecker (in IP20 über Klemmen).

 


Leitungsschutz: Wird das Modul über einen M12-Anschluss mit A- oder B-Codierung versorgt, darf es gem. IEC 61076-2-101 und IEC 61076-2-109 nur mit einer Strombelastung von max. 4 A pro Pin betrieben werden. Ein gesicherter Abgriff wird empfohlen. Für Module, die über Profilkabel und Durchdringungstechnik versorgt werden, gilt diese Einschränkung nicht.

ASi Anschluss
Required Master profile ASi node profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Bihl+Wiedemann
Article No.
Figure
ASI67FFP40E Schneider ElectricIP67, 4 x M124-standardASi Profilkabel≥M3S-0.A.(7).01 AB AdresseBWU3556
Bihl+Wiedemann Article No. BWU3556
Bihl+WiedemannIP67, 4 x M124-SingleASi Profilkabel≥M3S-0.A.(7).01 AB address (S-0.A.7.0)
ASI67FMP43E Schneider ElectricIP67, 8 x M1243 x elektronischstandardASi über M12≥M3S-7.A.(7).01 AB AdresseBWU3496
Bihl+Wiedemann Article No. BWU3496
Bihl+WiedemannIP67, 8 x M1243 x elektronischSingleASi Profilkabel≥M3S-7.A.(7).01 AB Adresse

 

 

Schneider Electric, Overview of functionally equivalent products: Digital Modules ASi, IP67, M12 - same required master profile

  • + Same number I/Os
  • + Same protection rating
  • + Same required master profile
  • + Same dimensions/housing
  • ‒ Different node profile
  • ‒ Different pin assignment
Schneider Electric Article No. Manufacturer Typ Inputs digital Outputs digital

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.

M8/M12 wiring

Die Anbindung an ASi und an AUX (24 V Hilfsenergie) erfolgt über das gelbe bzw. schwarze ASi Profilkabel mit Durchdringungstechnik oder über einen M12-Stecker (in IP20 über Klemmen).

 


Leitungsschutz: Wird das Modul über einen M12-Anschluss mit A- oder B-Codierung versorgt, darf es gem. IEC 61076-2-101 und IEC 61076-2-109 nur mit einer Strombelastung von max. 4 A pro Pin betrieben werden. Ein gesicherter Abgriff wird empfohlen. Für Module, die über Profilkabel und Durchdringungstechnik versorgt werden, gilt diese Einschränkung nicht.

ASi Anschluss
Required Master profile ASi node profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Bihl+Wiedemann
Article No.
Figure
ASI67FFP04A Schneider ElectricIP67, 4 x M12-4 x elektronischstandardASi Profilkabel≥M0S-8.0.(F).F1 Single AdresseBWU2713
Bihl+Wiedemann Article No. BWU2713
Bihl+WiedemannIP67, 4 x M12-4 x elektronischYASi Profilkabel≥M0S-7.F.(F).E1 Single Adresse
ASI67FFP04D Schneider ElectricIP67, 4 x M12-4 x elektronischstandardASi Profilkabel≥M0S-8.0.(F).E1 Single AdresseBWU2713
Bihl+Wiedemann Article No. BWU2713
Bihl+WiedemannIP67, 4 x M12-4 x elektronischYASi Profilkabel≥M0S-7.F.(F).E1 Single Adresse
ASI67FMP04D Schneider ElectricIP67, 4 x M12-4 x elektronischstandardASi über M12≥M0S-8.0.(F).E1 Single AdresseBWU2713
Bihl+Wiedemann Article No. BWU2713
Bihl+WiedemannIP67, 4 x M12-4 x elektronischYASi Profilkabel≥M0S-7.F.(F).E1 Single Adresse
ASI67FMP40E Schneider ElectricIP67, 4 x M124-standardASi über M12≥M3S-0.A.(7).01 AB AdresseBWU2620
Bihl+Wiedemann Article No. BWU2620
Bihl+WiedemannIP67, 4 x M124-SingleASi Profilkabel≥M3S-0.A.(7).E1 AB Adresse
ASI67FFP40EY Schneider ElectricIP67, 4 x M124-dual (Y)ASi Profilkabel≥M3S-0.A.(7).01 AB AdresseBWU2552
Bihl+Wiedemann Article No. BWU2552
Bihl+WiedemannIP67, 4 x M124-YASi Profilkabel≥M3S-0.A.(7).E1 AB Adresse
ASI67FFP43EY Schneider ElectricIP67, 8 x M1243 x elektronischdual (Y)ASi Profilkabel≥M3S-7.A.(7).E1 AB AdresseBWU3496
Bihl+Wiedemann Article No. BWU3496
Bihl+WiedemannIP67, 8 x M1243 x elektronischSingleASi Profilkabel≥M3S-7.A.(7).01 AB Adresse
ASI67FFP43EY Schneider ElectricIP67, 8 x M1243 x elektronischdual (Y)ASi Profilkabel≥M3S-7.A.(7).E1 AB AdresseBWU3375
Bihl+Wiedemann Article No. BWU3375
Bihl+WiedemannIP67, 4 x M1243 x elektronischYASi Profilkabel≥M3S-7.A.(7).01 AB Adresse
ASI67FMP43EY Schneider ElectricIP67, 8 x M1243 x elektronischdual (Y)ASi über M12≥M3S-7.A.(7).E1 AB AdresseBWU3496
Bihl+Wiedemann Article No. BWU3496
Bihl+WiedemannIP67, 8 x M1243 x elektronischSingleASi Profilkabel≥M3S-7.A.(7).01 AB Adresse
ASI67FFP44A Schneider ElectricIP67, 8 x M1244 x elektronischstandardASi Profilkabel≥M0S-7.0.(F).F1 Single AdresseBWU2684
Bihl+Wiedemann Article No. BWU2684
Bihl+WiedemannIP67, 8 x M1244 x elektronischSingleASi Profilkabel≥M0S-7.0.(F).E1 Single Adresse
ASI67FMP44D Schneider ElectricIP67, 8 x M1244 x elektronischstandardASi über M12≥M0S-7.F.(F).E1 Single AdresseBWU2684
Bihl+Wiedemann Article No. BWU2684
Bihl+WiedemannIP67, 8 x M1244 x elektronischSingleASi Profilkabel≥M0S-7.0.(F).E1 Single Adresse

 

 

Schneider Electric, Overview of functionally equivalent products: Digital Modules ASi, IP67, M12

  • + Same number of I/Os
  • + Same protection rating
  • + Same dimensions/housing ‒ Different node profile
  • ‒ Different required master profile
  • ‒ Different pin assignment
Schneider Electric Article No. Manufacturer Typ Inputs digital Outputs digital

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.

M8/M12 wiring

Die Anbindung an ASi und an AUX (24 V Hilfsenergie) erfolgt über das gelbe bzw. schwarze ASi Profilkabel mit Durchdringungstechnik oder über einen M12-Stecker (in IP20 über Klemmen).

 


Leitungsschutz: Wird das Modul über einen M12-Anschluss mit A- oder B-Codierung versorgt, darf es gem. IEC 61076-2-101 und IEC 61076-2-109 nur mit einer Strombelastung von max. 4 A pro Pin betrieben werden. Ein gesicherter Abgriff wird empfohlen. Für Module, die über Profilkabel und Durchdringungstechnik versorgt werden, gilt diese Einschränkung nicht.

ASi Anschluss
Required Master profile ASi node profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Bihl+Wiedemann
Article No.
Figure
ASI67FFP03E Schneider ElectricIP67, 4 x M12-3 x elektronischstandardASi Profilkabel≥M3S-8.0.(F).F1 AB AdresseBWU2728
Bihl+Wiedemann Article No. BWU2728
Bihl+WiedemannIP67, 4 x M12-4 x elektronischYASi Profilkabel≥M4S-7.A.7.71 AB Adresse
ASI67FMP03E Schneider ElectricIP67, 4 x M12-3 x elektronischstandardASi über M12≥M3S-8.0.(F).F1 AB AdresseBWU2728
Bihl+Wiedemann Article No. BWU2728
Bihl+WiedemannIP67, 4 x M12-4 x elektronischYASi Profilkabel≥M4S-7.A.7.71 AB Adresse
ASI67FFP22A Schneider ElectricIP67, 4 x M1222 x electronicstandardASi Profilkabel≥M0S-3.0.(F).F1 Single AdresseBWU3141
Bihl+Wiedemann Article No. BWU3141
Bihl+WiedemannIP67, 4 x M1222 x electronicSingleASi Profilkabel≥M4S-7.A.7.71 AB Adresse
ASI67FFP22D Schneider ElectricIP67, 4 x M1222 x electronicstandardASi Profilkabel≥M0S-3.0.(F).E1 Single AdresseBWU3141
Bihl+Wiedemann Article No. BWU3141
Bihl+WiedemannIP67, 4 x M1222 x electronicSingleASi Profilkabel≥M4S-7.A.7.71 AB Adresse
ASI67FMP22D Schneider ElectricIP67, 4 x M1222 x electronicstandardASi über M12≥M0S-3.0.(F).E1 Single AdresseBWU3517
Bihl+Wiedemann Article No. BWU3517
Bihl+WiedemannIP67, 4 x M1222 x electronicSingleASi über M12≥M4S-7.A.7.71 AB Adresse
ASI67FFP22E Schneider ElectricIP67, 4 x M1222 x electronicstandardASi Profilkabel≥M3S-B.A.(7).01 AB AdresseBWU3141
Bihl+Wiedemann Article No. BWU3141
Bihl+WiedemannIP67, 4 x M1222 x electronicSingleASi Profilkabel≥M4S-7.A.7.71 AB Adresse
ASI67FMP22E Schneider ElectricIP67, 4 x M1222 x electronicstandardASi über M12≥M3S-B.A.(7).01 AB AdresseBWU3517
Bihl+Wiedemann Article No. BWU3517
Bihl+WiedemannIP67, 4 x M1222 x electronicSingleASi über M12≥M4S-7.A.7.71 AB Adresse
ASI67FFP40A Schneider ElectricIP67, 4 x M124-standardASi Profilkabel≥M0S-0.0.(F).F1 Single AdresseBWU2620
Bihl+Wiedemann Article No. BWU2620
Bihl+WiedemannIP67, 4 x M124-SingleASi Profilkabel≥M3S-0.A.(7).E1 AB Adresse
ASI67FMP40D Schneider ElectricIP67, 4 x M124-standardASi über M12≥M0S-0.0.F.E1 Single AdresseBWU3457
Bihl+Wiedemann Article No. BWU3457
Bihl+WiedemannIP67, 4 x M124-SingleASi über M12≥M3S-0.A.(7).E1 AB Adresse
ASI67FMP40D Schneider ElectricIP67, 4 x M124-standardASi über M12≥M0S-0.0.F.E1 Single AdresseBWU3556
Bihl+Wiedemann Article No. BWU3556
Bihl+WiedemannIP67, 4 x M124-SingleASi Profilkabel≥M3S-0.A.(7).01 AB address (S-0.A.7.0)
ASI67FMP40EY Schneider ElectricIP67, 4 x M124-dual (Y)ASi über M12≥M3S-0.A.(7).01 AB AdresseBWU3077
Bihl+Wiedemann Article No. BWU3077
Bihl+WiedemannIP67, 4 x M124-YASi über M12≥M3S-0.A.(7).E1 AB Adresse
ASI67FFP44DY Schneider ElectricIP67, 8 x M1244 x elektronischdual (Y)ASi Profilkabel≥M0S-7.F.(F).E1 Single AdresseBWU2626
Bihl+Wiedemann Article No. BWU2626
Bihl+WiedemannIP67, 8 x M1244 x elektronischYASi Profilkabel≥M4S-7.A.7.71 AB Adresse
ASI67FMP44DY Schneider ElectricIP67, 8 x M1244 x elektronischdual (Y)ASi über M12≥M0S-7.F.(F).E1 Single AdresseBWU2626
Bihl+Wiedemann Article No. BWU2626
Bihl+WiedemannIP67, 8 x M1244 x elektronischYASi Profilkabel≥M4S-7.A.7.71 AB Adresse
ASI67FFP80DY Schneider ElectricIP67, 8 x M128-dual (Y)ASi Profilkabel≥M0S1-0.1.(F).F, S2-0.1.(F).F2 Single addressesBWU2770
Bihl+Wiedemann Article No. BWU2770
Bihl+WiedemannIP67, 8 x M128-YASi Profilkabel≥M3S1-7.A.7.7, S2-7.A.(6).72 AB Adressen
ASI67FFP80DY Schneider ElectricIP67, 8 x M128-dual (Y)ASi Profilkabel≥M0S1-0.1.(F).F, S2-0.1.(F).F2 Single addressesBWU2651
Bihl+Wiedemann Article No. BWU2651
Bihl+WiedemannIP67, 8 x M128-YASi Profilkabel≥M3S1-7.A.7.7, S2-7.A.(6).72 AB Adressen

 

 

Schneider Electric, Overview of functionally equivalent products: Digital Modules ASi, IP20 - same node profile

  • + Same number I/Os
  • + Same protection rating
  • + Same node profile
  • + Same required master profile
  • ‒ Different terminal assignment
  • ‒ Different dimensions/housing
Schneider Electric Article No. Manufacturer Typ Inputs digital Outputs digital Required Master profile ASi node profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Bihl+Wiedemann
Article No.
Figure
ASI20MT4I4OR Schneider ElectricIP20, 25 mm x 87 mm, 2 x Klemmenblock44 x relay≥M0S-7.0.(F).E1 Single AdresseBWU3658
Bihl+Wiedemann Article No. BWU3658
Bihl+WiedemannIP20, 22,5 mm x 114 mm, 6 x 4 Kontakte44 x relay≥M0S-7.0.(F).E1 Single Adresse (S-7.0.F.E)
ASI20MT4I4OS Schneider ElectricIP20, 25 mm x 87 mm, 2 x Klemmenblock44 x elektronisch≥M0S-7.0.(F).E1 Single AdresseBWU3754
Bihl+Wiedemann Article No. BWU3754
Bihl+WiedemannIP20, 22,5 mm x 114 mm, 6 x 4 Kontakte44 x elektronisch≥M0S-7.0.(F).E1 Single Adresse
ASI20MT4I3OSAE Schneider ElectricIP20, 25 mm x 87 mm, 2 x Klemmenblock43 x elektronisch≥M3S-7.A.(7).01 AB AdresseBWU3733
Bihl+Wiedemann Article No. BWU3733
Bihl+WiedemannIP20, 22,5 mm x 92 mm, 4 x 4 Kontakte43 x elektronisch≥M3S-7.A.(7).01 AB Adresse
ASI20MT4I4OSA Schneider ElectricIP20, 25 mm x 87 mm, 2 x Klemmenblock44 x elektronisch≥M0S-7.0.(F).E1 Single AdresseBWU2759
Bihl+Wiedemann Article No. BWU2759
Bihl+WiedemannIP20, 22,5 mm x 114 mm, 4 x 4 Kontakte44 x elektronisch≥M0S-7.0.(F).E1 Single Adresse
ASI20MT4IE Schneider ElectricIP20, 25 mm x 87 mm, 1 x Klemmenblock4-≥M3S-0.A.(7).01 AB AdresseBWU3747
Bihl+Wiedemann Article No. BWU3747
Bihl+WiedemannIP20, 22,5 mm x 50 mm, 4 x 4 Kontakte4-≥M3S-0.A.(7).01 AB Adresse

 

 

Schneider Electric, Overview of functionally equivalent products: Digital Modules ASi, IP20 - same required master profile

  • + Same number I/Os
  • + Same protection rating
  • + Same required master profile
  • ‒ Different node profile
  • ‒ Different terminal assignment
  • ‒ Different dimensions/housing
Schneider Electric Article No. Manufacturer Typ Inputs digital Outputs digital Required Master profile ASi node profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Bihl+Wiedemann
Article No.
Figure
ASI20MT4I3ORE Schneider ElectricIP20, 25 mm x 87 mm, 2 x Klemmenblock43 x relay≥M3S-7.A.(7).01 AB AdresseBW1808
Bihl+Wiedemann Article No. BW1808
Bihl+WiedemannEdelstahl in IP20, 45 mm tief43 x relay≥M3S-7.A.(7).E1 AB Adresse

 

 

Schneider Electric, Overview of functionally equivalent products: Digital Modules ASi, IP20

  • + Same number I/Os
  • + Same protection rating
  • ‒ Different node profile
  • ‒ Different required master profile
  • ‒ Different terminal assignment
  • ‒ Different dimensions/housing
Schneider Electric Article No. Manufacturer Typ Inputs digital Outputs digital Required Master profile ASi node profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Bihl+Wiedemann
Article No.
Figure
ASI20MT4I3OSA Schneider ElectricIP20, 25 mm x 87 mm, 2 x Klemmenblock43 x elektronisch≥M3S-7.A.(7).01 AB AdresseBWU2783
Bihl+Wiedemann Article No. BWU2783
Bihl+WiedemannIP20, 22,5 mm x 50 mm, 4 x 4 Kontakte44 x elektronisch≥M4S-7.A.7.71 AB Adresse
ASI20MT4I3OSE Schneider ElectricIP20, 25 mm x 87 mm, 2 x Klemmenblock43 x elektronisch≥M3S-7.A.(7).01 AB AdresseBWU2783
Bihl+Wiedemann Article No. BWU2783
Bihl+WiedemannIP20, 22,5 mm x 50 mm, 4 x 4 Kontakte44 x elektronisch≥M4S-7.A.7.71 AB Adresse

 

 

Schneider Electric, Overview of functionally equivalent products: Analog Modules ASi, IP20 - same node profile

  • + Same number I/Os
  • + Same protection rating
  • + Same node profile
  • + Same required master profile
  • ‒ Different terminal assignment
  • ‒ Different dimensions/housing
Schneider Electric Article No. Manufacturer Typ Eingänge analog Ausgänge analog Required Master profile ASi node profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Bihl+Wiedemann
Article No.
Figure
ASI20MA2VI Schneider ElectricIP20, 25 mm x 87 mm, 2 x Klemmenblock2 x 4 … 20 mA-≥M3S-7.3.(F).D1 Single AdresseBWU1345
Bihl+Wiedemann Article No. BWU1345
Bihl+WiedemannIP20, 22,5 mm x 92 mm, 4 x 4 Kontakte2 x 4 ... 20 mA/2 x 0 … 10 V-≥M3S-7.3.(F).D1 Single Adresse
ASI20MA2VU Schneider ElectricIP20, 25 mm x 87 mm, 2 x Klemmenblock2 x 0 ... 10 V-≥M3S-7.3.(F).D1 Single AdresseBWU1345
Bihl+Wiedemann Article No. BWU1345
Bihl+WiedemannIP20, 22,5 mm x 92 mm, 4 x 4 Kontakte2 x 4 ... 20 mA/2 x 0 … 10 V-≥M3S-7.3.(F).D1 Single Adresse

 

 

Schneider Electric, Overview of functionally equivalent products: Passive Distributors

  • Passive Distributors ASi, IP67
  • Passive Distributors ASi/AUX, IP67
Schneider Electric Article No. Manufacturer Typ Gehäuseart

"IP20":
Geschützt gegen feste Fremdkörper mit Durchmesser ab 12,5 mm und gegen den Zugang mit einem Finger, kein Schutz vor Wasser.

"IP40":
Geschützt gegen feste Fremdkörper mit Durchmesser ab 1,0 mm, geschützt gegen den Zugang mit einem Draht, kein Schutz vor Wasser.

"IP54":
Schutz gegen Staub in schädigender Menge, vollständiger Schutz gegen Berührungen, Schutz gegen allseitiges Spritzwasser.

"IP65":
Staubdicht, vollständiger Schutz gegen Berührungen, Schutz gegen Strahlwasser (Düse) aus beliebigem Winkel.

"IP67":
Staubdicht, vollständiger Schutz gegen Berührungen, Schutz gegen zeitweiliges Untertauchen.

Schutzart

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible
Profile cable connection

PUR-Leitung, ölfest. Weitere Anschlussvarianten sind auf Anfrage möglich.

 

      M12-Buchse   M12-Kabelbuchse, gewinkelt   M12-Kabelbuchse, gerade  M8-Kabelbuchse, geradeRundkabel/Anschlusslitzen     Profilkabelabzweig          Push-In Klemmen

 

       2 x Rundkabel/Anschlusslitzen 2,5 mm²           Federzugklemmen 2,5 mm²
Anschluss

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

Round cable
Bihl+Wiedemann
Article No.
Figure
TCSATN011F2 Schneider ElectricPassivverteiler ASi19 mm tiefIP67ja, 19 mm tief1 x ASi1 x M12-Kabelbuchse, gewinkelt, 5-polig2 mBW1977
Bihl+Wiedemann Article No. BW1977
Bihl+WiedemannPassivverteiler ASi19 mm tiefIP67ja, 19 mm tief1 x ASi1 x M12-Kabelbuchse, gewinkelt, 5-polig2 m
TCSATN011F2 Schneider ElectricPassivverteiler ASi19 mm tiefIP67ja, 19 mm tief1 x ASi1 x M12-Kabelbuchse, gewinkelt, 5-polig2 mBWU3247
Bihl+Wiedemann Article No. BWU3247
Bihl+WiedemannPassivverteiler ASi19 mm tiefIP67ja, 19 mm tief2 x ASi1 x M12-Kabelbuchse, gerade, 5-polig2 m
TCSATN02V Schneider ElectricPassivverteiler ASi19 mm tiefIP67ja, 19 mm tief2 x ASiProfilkabelabzweigneinBW1975
Bihl+Wiedemann Article No. BW1975
Bihl+WiedemannPassivverteiler ASi19 mm tiefIP67ja, 19 mm tief2 x ASiProfilkabelabzweignein
TCSATN02V Schneider ElectricPassivverteiler ASi19 mm tiefIP67ja, 19 mm tief2 x ASiProfilkabelabzweigneinBWU3493
Bihl+Wiedemann Article No. BWU3493
Bihl+WiedemannPassivverteiler ASi/AUX35 mm tiefIP67nein1 x ASi, 1 x AUX 24 V1 x M12-Buchse, 5-polignein
TCSATV011F2 Schneider ElectricPassivverteiler ASi/AUX19 mm tiefIP67ja, 19 mm tief1 x ASi, 1 x AUX 24 V1 x M12-Kabelbuchse, gewinkelt, 5-polig2 mBW1974
Bihl+Wiedemann Article No. BW1974
Bihl+WiedemannPassivverteiler ASi/AUX19 mm tiefIP67ja, 19 mm tief1 x ASi, 1 x AUX 24 V1 x M12-Kabelbuchse, gewinkelt, 5-polig2 m
TCSATV011F2 Schneider ElectricPassivverteiler ASi/AUX19 mm tiefIP67ja, 19 mm tief1 x ASi, 1 x AUX 24 V1 x M12-Kabelbuchse, gewinkelt, 5-polig2 mBWU3183
Bihl+Wiedemann Article No. BWU3183
Bihl+WiedemannPassivverteiler ASi/AUX19 mm tiefIP67ja, 19 mm tief1 x ASi, 1 x AUX 24 V1 x M12-Kabelbuchse, gewinkelt, 5-polig2 m
TCSATV01N2 Schneider ElectricPassivverteiler ASi/AUX19 mm tiefIP67ja, 19 mm tief1 x ASi, 1 x AUX 24 V1 x Rundkabel/Anschlusslitzen2 mBWU3314
Bihl+Wiedemann Article No. BWU3314
Bihl+WiedemannPassivverteiler ASi/AUX19 mm tiefIP67ja, 19 mm tief1 x ASi, 1 x AUX 24 V1 x Rundkabel/Anschlusslitzen2 m

 

 

Schneider Electric, Overview of functionally equivalent products: Power Supply

  • ‒ No earth fault and EMC monitor integrated in the power supply, all current Bihl + Wiedemann gateways have an integrated earth fault and EMC monitor
Schneider Electric Article No. Manufacturer

"ASi power supply":

Special power supplies with integrated data decoupling unit for use in ASi-3 only networks. Suitable for all Bihl+Wiedemann ASi-3 gateways and safety monitors.

"30 V power supply":

Inexpensive standard power supplies, suitable as an alternative for use with ASi gateways and safety monitors with integrated data decoupling unit (version "1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi gateways.


30 V power supply, optimized for ASi-5/ASi-3:

Inexpensive standard power supplies, optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated data decoupling unit (version "1 power supply , 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.


30 V power supply, optimized for ASi-5/ASi-3, NEC class 2 :

The 30 V/3 A power supply is UL certified, has power limitation <100 W and is designed for use in NEC class 2 networks. It is suitable for applications with 1 power supply per ASi network. In the case of power intensive applications, Bihl+Wiedemann recommends the use of a 30 V power supply without 100 W power limitation in combination with a power limitation module (BWU4189) for each ASi network.The power supply is optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated decoupling coils (version "1 power supplies, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 V ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.


"ASi power supply decoupling unit":

Supply of 2 ASi networks out of 1 power supply. Applicable with double masters without integrated data decoupling.


"Power decoupling unit":

Take up to 1,2 A out of ASi. In combination with an ASi Repeater: decouples 1,2 A from ASi Segment B and supplies Segment A with 1,2 A.

Power supply
Input voltage Output current

"IP20":
Geschützt gegen feste Fremdkörper mit Durchmesser ab 12,5 mm und gegen den Zugang mit einem Finger, kein Schutz vor Wasser.

"IP40":
Geschützt gegen feste Fremdkörper mit Durchmesser ab 1,0 mm, geschützt gegen den Zugang mit einem Draht, kein Schutz vor Wasser.

"IP54":
Schutz gegen Staub in schädigender Menge, vollständiger Schutz gegen Berührungen, Schutz gegen allseitiges Spritzwasser.

"IP65":
Staubdicht, vollständiger Schutz gegen Berührungen, Schutz gegen Strahlwasser (Düse) aus beliebigem Winkel.

"IP67":
Staubdicht, vollständiger Schutz gegen Berührungen, Schutz gegen zeitweiliges Untertauchen.

Schutzart
Bihl+Wiedemann
Article No.
Figure
ASIABLB3002Schneider ElectricASi Netzteil100 ... 240 VAC, 1-phasig2,4 AIP20BW1649
Bihl+Wiedemann Article No. BW1649
Bihl+WiedemannASi Netzteil90 ... 265 VAC, Weitbereichsnetzteil4 AIP20
ASIABLB3004Schneider ElectricASi Netzteil100 ... 240 VAC, 1-phasig4,8 AIP20BW1997
Bihl+Wiedemann Article No. BW1997
Bihl+WiedemannASi Netzteil115 VAC / 230 VAC, Netzteil mit Bereichswahlschalter8 AIP20
ASIABLD3002Schneider ElectricASi Netzteil100 ... 240 VAC, 1-phasig2,4 AIP20BW1649
Bihl+Wiedemann Article No. BW1649
Bihl+WiedemannASi Netzteil90 ... 265 VAC, Weitbereichsnetzteil4 AIP20
ASIABLD3004Schneider ElectricASi Netzteil100 ... 240 VAC, 1-phasig4,8 AIP20BW1997
Bihl+Wiedemann Article No. BW1997
Bihl+WiedemannASi Netzteil115 VAC / 230 VAC, Netzteil mit Bereichswahlschalter8 AIP20

 

Schneider Electric, Overview of equivalent products: Circuit Extension

  • ASi Bus Termination
  • ASi Repeater
Schneider Electric Article No. Bihl+Wiedemann
Article No.
Figure
TCSAAR011MBWU1644
Bihl+Wiedemann Article No. BWU1644
ASIRPT01BWU1273
Bihl+Wiedemann Article No. BWU1273

 

 

Schneider Electric, Overview of equivalent products: Diagnostics / Commissioning

  • ASi Analyser
  • ASi Address Programming Device
  • Accessories for ASi Address Programming Device
Schneider Electric Article No. Bihl+Wiedemann
Article No.
Figure
ASISA01BWU1415
Bihl+Wiedemann Article No. BWU1415
XZMC11BW1191
Bihl+Wiedemann Article No. BW1191
XZMC11BW1646
Bihl+Wiedemann Article No. BW1646
ASITERACC2BW1802
Bihl+Wiedemann Article No. BW1802
ASITERIR1BW1935
Bihl+Wiedemann Article No. BW1935

 

 

Schneider Electric, Overview of equivalent products: Accessories

  • Substructure Modules for IP67 modules
  • ASi profile cable, yellow
  • ASi profile cable, black
Schneider Electric Article No. Bihl+Wiedemann
Article No.
Figure
ASI67FFB01BWU2349
Bihl+Wiedemann Article No. BWU2349
ASI67FFB02BWU2350
Bihl+Wiedemann Article No. BWU2350
ASI67FFB03BWU2351
Bihl+Wiedemann Article No. BWU2351
ASI67FACC1BW2368
Bihl+Wiedemann Article No. BW2368
XZCB11001BW2756
Bihl+Wiedemann Article No. BW2756
XZCB11001HBW1979
Bihl+Wiedemann Article No. BW1979
XZCB11002BW2757
Bihl+Wiedemann Article No. BW2757
XZCB11002HBW1980
Bihl+Wiedemann Article No. BW1980
XZCE40BW1945
Bihl+Wiedemann Article No. BW1945