Logo Bihl+Wiedemann GmbH

Archives Modules/Slaves

Archives Digital Modules in IP67

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

either as a single–wiring, Y–wiring or mixed-wiring.

 

M12 (5 poles)
Single-wiringY-wiringMixed-wiring
M8 (3 poles)
Single wiring

 

M8/M12 wiring

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Article No.
BWU3449IP67, 4 x M124 x M12IP6722 x electronic, special ASi bit assignmentYout of ASiout of AUX4 x M12 sockets, 5 polesASi profile cable1 AB Slave

Archive digital modules in IP67 - replacement compatible with Schneider Electric

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

either as a single–wiring, Y–wiring or mixed-wiring.

 

M12 (5 poles)
Single-wiringY-wiringMixed-wiring
M8 (3 poles)
Single wiring

 

M8/M12 wiring

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
ASi slave profile Required Master profile Article No.
BWU3682IP67, 4 x M124 x M12IP674-standardout of ASi-4 x M12 sockets, 5 polesASi profile cable1 Single SlaveS-0.0.F.E≥M0
BWU3701IP67, 8 x M128 x M12IP6743 x electronicstandardout of ASiout of AUX, 2 A per output8 x M12 sockets, 5 polesASi profile cable1 AB SlaveS-7.A.(7).0≥M3
BWU3686IP67, 8 x M128 x M12IP6744 x electronicstandardout of ASiout of AUX, 2 A per output8 x M12 sockets, 5 polesASi profile cable1 Single Slave (S-7.0.F.E)S-7.0.(F).E≥M0
BWU3523IP67, 8 x M128 x M12IP678-dual (Y)out of ASi-8 x M12 sockets, 5 polesASi profile cable2 AB SlavesS1-0.A.(7).2, S2-0.A.(7).2≥M3

Archiv: Active Distributor ASi, IP67/IP54/IP20

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

either as a single–wiring, Y–wiring or mixed-wiring.

 

M12 (5 poles)
Single-wiringY-wiringMixed-wiring
M8 (3 poles)
Single wiring

 

M8/M12 wiring

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi slaves) however only the one ASi profile cable is counted.

Round cable

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible
Profile cable connection

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Special function Article No.
BWU3625Active distributor ASidepth: 35 mmIP671-out of ASi-1 x M12 cable socket, angled, 5 poles-2 myes, depth: 35 mm1 x ASiASi profile cable1 Single Slave-
BWU3676Active distributor ASidepth: 35 mmIP5444 x electronicout of AUXout of AUX3 x M12 cable sockets, straight, 5 poles + 2 x M8 snap-in cable sockets, straight, 4 poles + 1 x ASi addressing cable socket-I1/I2: 0,1 m, I3/I4: 0,3 m, O1/O2: 0,2 m, O3/O4: 0,3 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slave-

 

 

Archives Analog Modules

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs analog Outputs analog

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Article No.
BWU1726IP20, 22,5 mm x 92 mm, 4 x COMBICON4 x COMBICONIP202 x 4 ... 20 mA/2 x 0 … 10 V-out of ASi-clamps1 Single Slave
BWU1465IP65, 3 x PG3 x PGIP65Load cell-out of ASi-ASi profile cable1 Single Slave
BWU2241IP65, 8 x PG8 x PGIP654 x Pt100 -out of ASi-ASi profile cable1 Single Slave
BWU1893IP65, 2 x M12, width: 45 mmwidth: 45 mm IP652 x 4 … 20 mA-out of ASi-ASi profile cable1 AB Slave
BWU1894IP65, 2 x M12, width: 45 mmwidth: 45 mm IP652 x 4 … 20 mA-out of ASi-ASi profile cable1 Single Slave
BWU1963IP65, 2 x M12, width: 45 mmwidth: 45 mm IP652 x 0 ... 10 V-out of ASi-ASi profile cable1 AB Slave
BWU1964IP65, 2 x M12, width: 45 mmwidth: 45 mm IP652 x 0 ... 10 V-out of ASi-ASi profile cable1 Single Slave
BWU1895IP65, 2 x M12, width: 45 mmwidth: 45 mm IP652 x Pt100-out of ASi-ASi profile cable1 AB Slave
BWU1897IP20, 22,5 mm x 92 mm, 4 x COMBICON4 x COMBICONIP202 x 4 ... 20 mA/2 x 0 … 10 V-selectable, out of ASi or out of AUX, Default out of ASi-clamps1 AB Slave
BWU1917IP65, 4 x M12, width: 90 mmwidth: 90 mm IP651 x 4 … 20 mA/0 … 10 V1x 0 … 20 mAout of ASiout of ASiASi profile cable2-4 Single Slaves