Logo Bihl+Wiedemann GmbH

Phoenix Contact

Product overview

In the following article overview you will find Bihl+Wiedemann products which can be used as replacement articles for Phoenix Contact products. Since Phoenix Contact no longer markets the products listed here themselves, you may source these replacement articles from us in the future.

Phoenix Contact, Overview of equivalent products: Master/Gateways

  • When using an equivalent Bihl+Wiedemann Gateway as a replacement for a Phoenix Contact Gateway, the device description file must be reinstalled.
  • The latest version of the device description file (GSD, EDS, XDD etc.) of the gateway is available in the "Downloads" section of the respective device.
Phoenix Contact Article No. Bihl+Wiedemann
Article No.
Figure
ASI MA PB XL AB - 2741710BWU1249
Bihl+Wiedemann Article No. BWU1249
FLX ASI MA 2PB EF - 2773607BWU1568
Bihl+Wiedemann Article No. BWU1568
FLX ASI MA PB SF - 2773597BWU1746
Bihl+Wiedemann Article No. BWU1746
ASI MA PC PCI - 2741257BW1195
Bihl+Wiedemann Article No. BW1195

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP67, M12

  • + Same number I/Os
  • + Same protection rating
  • ‒ Different dimensions/housing
  • ‒ Different slave profile
  • ‒ Different required master profile
  • ‒ Different pin assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Total current for power supply of attached sensors. Please refer to additional specifications in the datasheet.

Max. current for sensor supply

Max. current per output for powering connected actuators. Please refer to additional specifications in the datasheet

Max. output current

either as a single–wiring, Y–wiring or mixed-wiring.

 

M12 (5 poles)
Single-wiringY-wiringMixed-wiring
M8 (3 poles)
Single wiring

 

M8/M12 wiring

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection
ASi slave profile Required Master profile

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
FLX ASI 3.0 DIO 4/4 M12-2A - 2773474Phoenix ContactIP67, 4 x M1244 x electronicout of ASiout of AUX200 mA4 AY4 x M12 sockets, 5 polesS-7.A.7.≥M21 AB SlaveASi profile cableBWU3144
Bihl+Wiedemann Article No. BWU3144
Bihl+WiedemannIP67, 8 x M12, EXTREME44 x electronicout of ASiout of AUX--Y8 x M12 sockets, 5 poles--1 AB SlaveASi profile cable
FLX ASI 3.0 DIO 4/4 M12-2A - 2773474Phoenix ContactIP67, 4 x M1244 x electronicout of ASiout of AUX200 mA4 AY4 x M12 sockets, 5 polesS-7.A.7.≥M21 AB SlaveASi profile cableBWU2626
Bihl+Wiedemann Article No. BWU2626
Bihl+WiedemannIP67, 8 x M1244 x electronicout of ASiout of AUX--Y8 x M12 sockets, 5 polesS-7.A.7.7≥M41 AB SlaveASi profile cable
FLX ASI DIO 4/3 M12-2A - 2773445Phoenix ContactIP67, 4 x M1243 x electronicout of ASiout of AUX200 mA4 AY4 x M12 sockets, 5 polesS-7.A.2.≥M31 AB SlaveASi profile cableBWU3375
Bihl+Wiedemann Article No. BWU3375
Bihl+WiedemannIP67, 4 x M1243 x electronicout of ASiout of AUX--Y4 x M12 sockets, 5 polesS-7.A.(7).0≥M31 AB SlaveASi profile cable
FLX ASI DIO 4/3 M12-2A - 2773445Phoenix ContactIP67, 4 x M1243 x electronicout of ASiout of AUX200 mA4 AY4 x M12 sockets, 5 polesS-7.A.2.≥M31 AB SlaveASi profile cableBWU3496
Bihl+Wiedemann Article No. BWU3496
Bihl+WiedemannIP67, 8 x M1243 x electronicout of ASiout of AUX, 2 A per output--Single8 x M12 sockets, 5 polesS-7.A.(7).0≥M31 AB SlaveASi profile cable
FLX ASI DIO 2/2 M12-2A - 2773432Phoenix ContactIP67, 4 x M1222 x electronicout of ASiout of AUX200 mA4 AY4 x M12 sockets, 5 polesS-B.A.2.≥M31 AB SlaveASi profile cableBWU3456
Bihl+Wiedemann Article No. BWU3456
Bihl+WiedemannIP67, 4 x M1222 x electronicout of ASiout of AUX--Y4 x M12 sockets, 5 poles--1 AB SlaveASi profile cable
FLX ASI DIO 2/2 M12-2A - 2773432Phoenix ContactIP67, 4 x M1222 x electronicout of ASiout of AUX200 mA4 AY4 x M12 sockets, 5 polesS-B.A.2.≥M31 AB SlaveASi profile cableBWU3141
Bihl+Wiedemann Article No. BWU3141
Bihl+WiedemannIP67, 4 x M1222 x electronicout of ASiout of AUX--Single4 x M12 sockets, 5 polesS-7.A.7.7≥M41 AB SlaveASi profile cable

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP67, M8

  • + Same number I/Os
  • + Same protection rating
  • ‒ Different dimensions/housing
  • ‒ Different slave profile
  • ‒ Different required master profile
  • ‒ Different pin assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Total current for power supply of attached sensors. Please refer to additional specifications in the datasheet.

Max. current for sensor supply

Max. current per output for powering connected actuators. Please refer to additional specifications in the datasheet

Max. output current

either as a single–wiring, Y–wiring or mixed-wiring.

 

M12 (5 poles)
Single-wiringY-wiringMixed-wiring
M8 (3 poles)
Single wiring

 

M8/M12 wiring

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection
ASi slave profile Required Master profile

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
FLX ASI DIO 4/4 M8-1A - 2773416Phoenix ContactIP67, 8 x M844 x electronicout of ASiout of AUX200 mA4 ASingle8 x M8 sockets, 3 polesS-7.0.≥M21 Single SlaveASi via M12BW3661
Bihl+Wiedemann Article No. BW3661
Bihl+WiedemannIP67, 8 x M844 x electronicout of ASiout of AUX--Single8 x M8 sockets, 3 polesS-7.A.(7).0≥M41 AB SlaveASi profile cable
FLX ASI DIO 4/4 M8-1A - 2773416Phoenix ContactIP67, 8 x M844 x electronicout of ASiout of AUX200 mA4 ASingle8 x M8 sockets, 3 polesS-7.0.≥M21 Single SlaveASi via M12BWU2645
Bihl+Wiedemann Article No. BWU2645
Bihl+WiedemannIP67, 8 x M1244 x electronicout of AUXout of AUX--Single8 x M12 sockets, 5 polesS-7.A.7.7≥M41 AB SlaveASi via M12
FLX ASI DIO 4/4 M8-1A - 2773416Phoenix ContactIP67, 8 x M844 x electronicout of ASiout of AUX200 mA4 ASingle8 x M8 sockets, 3 polesS-7.0.≥M21 Single SlaveASi via M12BWU2684
Bihl+Wiedemann Article No. BWU2684
Bihl+WiedemannIP67, 8 x M1244 x electronicout of ASiout of AUX--Single8 x M12 sockets, 5 polesS-7.0.(F).E≥M01 Single SlaveASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix ContactIP67, 8 x M84-out of ASi-200 mA-Single8 x M8 sockets, 3 polesS-0.0.≥M21 Single SlaveASi via M12BWU2620
Bihl+Wiedemann Article No. BWU2620
Bihl+WiedemannIP67, 4 x M124-out of ASi---Single4 x M12 sockets, 5 polesS-0.A.(7).E≥M31 AB SlaveASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix ContactIP67, 8 x M84-out of ASi-200 mA-Single8 x M8 sockets, 3 polesS-0.0.≥M21 Single SlaveASi via M12BW3661
Bihl+Wiedemann Article No. BW3661
Bihl+WiedemannIP67, 8 x M844 x electronicout of ASiout of AUX--Single8 x M8 sockets, 3 polesS-7.A.(7).0≥M41 AB SlaveASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix ContactIP67, 8 x M84-out of ASi-200 mA-Single8 x M8 sockets, 3 polesS-0.0.≥M21 Single SlaveASi via M12BW3521
Bihl+Wiedemann Article No. BW3521
Bihl+WiedemannIP67, 8 x M88-out of ASi---Single8 x M8 sockets, 3 polesS1-0.A.(7).E, S2-0.A.(6).E≥M32 AB SlavesASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix ContactIP67, 8 x M84-out of ASi-200 mA-Single8 x M8 sockets, 3 polesS-0.0.≥M21 Single SlaveASi via M12BWU3457
Bihl+Wiedemann Article No. BWU3457
Bihl+WiedemannIP67, 4 x M124-out of ASi---Single4 x M12 sockets, 5 polesS-0.A.(7).E≥M31 AB SlaveASi via M12

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP20

  • + Same number I/Os
  • + Same protection rating
  • ‒ Different dimensions/housing
  • ‒ Different slave profile
  • ‒ Different required master profile
  • ‒ Different terminal assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Total current for power supply of attached sensors. Please refer to additional specifications in the datasheet.

Max. current for sensor supply

Max. current per output for powering connected actuators. Please refer to additional specifications in the datasheet

Max. output current

either as a single–wiring, Y–wiring or mixed-wiring.

 

M12 (5 poles)
Single-wiringY-wiringMixed-wiring
M8 (3 poles)
Single wiring

 

M8/M12 wiring

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection
ASi slave profile Required Master profile

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
ASI IO ME DI 4 AB - 2741671Phoenix ContactIP20, 25 mm x 105 mm, 6 x COMBICON4-selectable, out of ASi or out of AUX, Default out of ASi----clampsS-0.A.0.≥M41 AB SlaveclampsBWU3265
Bihl+Wiedemann Article No. BWU3265
Bihl+WiedemannIP20, 22,5 mm x 114 mm, 4 x COMBICON4-out of ASi----clampsS-7.A.(7).E≥M31 AB Slaveclamps
ASI IO ME DI 4 AB - 2741671Phoenix ContactIP20, 25 mm x 105 mm, 6 x COMBICON4-selectable, out of ASi or out of AUX, Default out of ASi----clampsS-0.A.0.≥M41 AB SlaveclampsBWU3266
Bihl+Wiedemann Article No. BWU3266
Bihl+WiedemannIP20, 22,5 mm x 114 mm, 4 x COMBICON4-out of AUX----clamps--1 AB Slaveclamps

 

 

Phoenix Contact, Overview of functionally equivalent products: Power Supply

  • ‒ No earth fault and EMC monitor integrated in the power supply, all current Bihl + Wiedemann gateways have an integrated earth fault and EMC monitor
Phoenix Contact Article No. Manufacturer

"ASi power supply":

Suitable for all ASi Gateways and Safety Monitors from Bihl + Wiedemann.

"30 V power supply":

Suitable for all ASi Gateways and Safety Monitors with specifications "1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies" and for all 24 Volt ASi Gateways.


"ASi power supply decoupling unit":

Supply of 2 ASi networks out of 1 power supply. Applicable with double masters without integrated data decoupling. "Power decoupling unit":

 

Take up to 1,2 A out of ASi. In combination with an ASi Repeater: decouples 1,2 A from ASi Segment B and supplies Segment A with 1,2 A.

Power supply
Operating voltage Output current

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Bihl+Wiedemann
Article No.
Figure
ASI QUINT 100-240/4.8 EFD - 2736699Phoenix ContactASi power supply100 V AC ... 240 V AC4,8 AIP20BW1649
Bihl+Wiedemann Article No. BW1649
Bihl+WiedemannASi power supply90 V AC ... 265 V AC, wide range supply4 AIP20

 

 

Phoenix Contact, Overview of equivalent products: Diagnostics/Commissioning

  • ASi Address Programming Device
  • Accessories for ASi Address Programming Device
  • Master Simulators
Phoenix Contact Article No. Bihl+Wiedemann
Article No.
Figure
ASI CC ADR - 2741338BW1191
Bihl+Wiedemann Article No. BW1191
ASI CC ADR CAB CINCH - 2741341BW1802
Bihl+Wiedemann Article No. BW1802
PB ECO LINK - 2741480BW1131
Bihl+Wiedemann Article No. BW1131

 

 

Phoenix Contact, Overview of equivalent products: Software

Phoenix Contact Article No. Bihl+Wiedemann
Article No.
Figure
AS-i Control ToolBW1203
Bihl+Wiedemann Article No. BW1203