Simple & Cost-effective Alternative by Bihl+Wiedemann

Passive Safety Technology – a Cost-effective Alternative

In principle, machine safety can be achieved in different ways but passive safety is becoming increasingly more important in fieldbus solutions – mainly due to the associated cost advantages and reduced complexity.

 

What is so Special about Passive Safety?

What distinguishes passive safety technology from classic fieldbus solutions for functional safety? With classic fieldbus solutions, a safe output is required for every actuator. The advantage: All actuators can be safely switched off individually. However, this level of flexibility is not always required, especially when entire groups of actuators have to be de-energized simultaneously. In this case, passive safety is a good and cost-effective alternative. This is because having many safe outputs greatly increases the total cost of the application. With passive safety, all outputs can be switched off and controlled without safety individually or, if required, entire groups of actuators can be switched off safely using a single safe output — simply by switching off the supply voltage to all connected actuators in the drive string.

 

How can Passive Safety be Realized with ASi?

To establish passive safety, you must make sure that the actuator cannot be externally supplied with power when the supply is switched off. In a best case scenario, the power supply for the actuators is galvanically isolated from the supply for communication and sensor systems.


This supply principle has always been used with ASi — especially the B+W modules. In the smart wiring system, the profile cables are separated from each other — as a system string in the lower part of the module — with the yellow ASi cable transmitting control signals and energy, and the black profile cable providing auxiliary energy. This can be realized up to a safety level of SIL3 or PLe.


Thanks to the smart wiring system ASi, communication and power supply of the module via ASi are always maintained if the periphery is selectively switched off via AUX line. This means that none of the participants in the bus communication fail — as happens often with Ethernet-based systems — and there are no unforeseen effects on other system parts. Through the bus, the module can additionally detect and report that the AUX voltage has been de-energized. This information can also be evaluated for diagnostics through the existing communication with the control system via ASi.


Fig.: In the event of a switch-off, communication and power supply to the sensor system are maintained via the yellow ASi cable (left figure) whereas no communication can take place in a comparable setup with Ethernet-based systems (right figure).

 

In practice, it may also be necessary to install several switched and unswitched AUX lines in the system in order to manage individual drive strings separately from one another. In the event of a switch-off, the safety-relevant actuators can be selectively de-energized from the switched AUX line. The non-safety-relevant peripherals, such as the sensors, are supplied with power via the unswitched AUX line. This means that not only bus communication, but also information from the sensors, remains available for these modules.


Within a system, different AUX lines can be used to de-energize individual drives or several drives.

 

The ASi wiring system also offers the possibility to realize the power supply of the periphery via the yellow ASi cable in addition to the bus communication. Therefore, it may not be necessary to lay an additional unswitched AUX if all non-safety-related peripherals in the string can be supplied from the yellow cable. For this purpose, B+W offers a wide range of products in its portfolio that reliably supply power to the sensors from ASi and the actuators from AUX.


In the event of a switch-off, power continues to be supplied to the connected sensor system via the yellow ASi cable so that communication is maintained, and the drive string can be switched off via AUX.

What are the Options for Applying Passive Safety in the Application?

Through Bihl+Wiedemann's broad product portfolio, you can easily integrate passive safety into your system — and use different IP protection classes. With our IP20 products, passively safe junctions can be utilized in a cost-optimized way inside the switching cabinet. It is also possible to shut down the AUX line locally in the field by integrating our dust and splash-proof IP67 modules into your system, while benefiting from a drastically reduced wiring effort with ASi. What's more, ASi can be seamlessly integrated into almost all commonly used automation systems.

Advantages of Passive Safety with Bihl+Wiedemann

    Safety up to
    SIL3/PLe

     

    The yellow ASi profile cable is used to transmit control signals and power and the black profile cable for auxiliary power. In this way, it can be ensured that all connected actuators are no longer supplied when the auxiliary power is switched off. Safety up to SIL3/PLe is easily possible. With 4-core round cable solutions, this level of safety can only be achieved with great effort.

    Sinking hardware
    costs

    In safety-related applications, a separate costly safe output is generally required for every actuator. With passive safety, on the other hand, a cost-effective standard output can be used for the operational switching of each actuator. In this case, it is possible to implement safety-related disconnection of actuator groups with just one safe output.

    Sensor systems
    always accessible

    The yellow ASi cable transmits control signals and power up to 8 A without interruption. This means that when the auxiliary power is switched off or the black profile cable disconnected, the sensor system remains accessible in the event of a safety situation.

    Efficient power
    supply

    The black profile cable transmits 16 A or 20 A, depending on the cable cross-section – thus significantly more power than typical M12 round cable solutions. This allows plenty of current to be distributed at a low price per meter. For example, this would be ideal for IO-Link solutions and for motors in conveyor applications. Learn more about efficient power supply.

    Savings Potential Through Passive Safety

    When you implement passive safety through Bihl+Wiedemann systems, you benefit from fewer safe outputs plus all the cost advantages that ASi offers. Thanks to profile cables and piercing technology, the wiring costs are significantly lower with ASi than with other fieldbus systems – you save up to 68 percent. This is because you do not need various pre-assembled connection cables and also spend less costly time on assembly. Read our wiring cost comparison for more information.

     

    Go to the wiring cost comparison

    Products by Bihl+Wiedemann

    For the simple setup of passive safety, you only need one safety monitor with local outputs combined with a contact extension. Operational switching of the actuators can be achieved with non-safe standard Bihl+Wiedemann products that are suitable for passive safety. This is because almost all of our new ASi-5 modules, such as the various ASi-5 modules with intergrated IO-Link master, and many of our ASi-3 modules, meet the requirements for passive safety.

    Be Sure to Check the Technical Requirements

     

    Passive safety can only be established if the following technical requirements are met:

     

    • Safe disconnection must be implemented in accordance with the requirements of the Machinery Directive 2006/42/EC and safety standards such as EN ISO 13849-1 or EN 62061.
    • The galvanic isolation of passively safe switched potentials as well as other potentials must always be ensured or prevented by excluding faults (e.g. protected laying of cables, protected installation of passive safety devices).

     

     

    What this means, in concrete terms for ASi systems, is that it is the easiest way to exclusively use ASi modules where the compliance with passive safety is explicitly stated in the data sheet. Furthermore, all modules with ASi and AUX should be supplied in an isolated manner via the yellow and black profile cables.

    Questions about our solutions?

    FAQs about Passive Safety

    La sicurezza passiva viene mantenuta quando i sensori esterni e la loro alimentazione vengono alimentati tramite le uscite dallo stesso potenziale AUX commutato a sicurezza passiva.

    Se per l'alimentazione si utilizzano distributori passivi, alimentati solo da ASi o da AUX, non è necessaria la separazione di potenziale e quindi la sicurezza passiva.

    Se per la distribuzione dell'alimentazione si utilizzano distributori passivi che portano il potenziale ASi e AUX, è necessaria una sicurezza passiva per poter interrompere l'alimentazione in modo sicuro in caso di spegnimento. Queste informazioni sono indicate nella scheda tecnica.

    Le derivazioni decentralizzate e a sicurezza passiva sono rese possibili da un modulo di uscita sicuro con connessione AUX. La successiva "traduzione" dal connettore femmina M12 al cavo profilato avviene tramite un distributore passivo. Per ulteriori informazioni, consultare le nostre informazioni sul prodotto.