Safety I/O Modules
BW3499ASi Safety I/O Module, IP67, M12, 6-8SI/2SO/16I/16O
- Simple and highly flexible configuration
Product description
ASi Safety I/O Module in IP67, with 8 x M12 sockets, 6-8 x 2 channels safe inputs (SIL 3, cat. 4) for floating contacts, optoelectronic protective devices, or complementary switch, up to 16 standard inputs, up to 2 release circuits (up to 2 x electronic safe outputs), up to 16 standars outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 8 x M12 sockets, 5 poles, without limitation of connector cable length (loop resistance 150Ω), ASi/AUX connection via M12
Technical data
Type | IP67, 8 x M12, Safety | ||||||||||||||||||||
Housing | 8 x M12 | ||||||||||||||||||||
Protection rating
"IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | IP67 | ||||||||||||||||||||
Inputs Safety, SIL 3, Cat. 4 | 6-8 x 2 channels; depending on configuration | ||||||||||||||||||||
Inputs digital, EDM
An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input. | up to 16, depending on configuration | ||||||||||||||||||||
Outputs Safety, SIL 3, cat. 4 | up to 2 release circuits, up to 2 x electronic safe outputs; depending on configuration | ||||||||||||||||||||
Outputs digital | up to 16 x electronic, depending on configuration | ||||||||||||||||||||
Safety signal inputs | floating contacts, optoelectronic protective devices, complementary switch | ||||||||||||||||||||
Input voltage (sensor supply)
inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | out of ASi | ||||||||||||||||||||
Output voltage (actuator supply)
Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | out of ASi | ||||||||||||||||||||
Length of connector cable | unlimited | ||||||||||||||||||||
Connection
PUR line, oil resistant. Further connection options are available on request.
| 8 x M12 sockets, 5 poles | ||||||||||||||||||||
ASi connection
The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| ASi via M12 | ||||||||||||||||||||
ASi address
AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed. | depending on configuration |
General information
Commissioning
Manuals
EPLAN Macros
Video Tutorial
- Video Tutorial: Tips & Tricks: Replacing a defective device (DE)
- Video Tutorial: Tips & Tricks: Replacing a defective device (EN)
- Video Tutorial: ASIMON360 configuration of Safety devices (DE)
- Video Tutorial: ASIMON360 configuration of Safety devices (EN)
- Video Tutorial: Tips & Tricks in ASIMON360: Online bus information (DE)
- Video Tutorial: Tips & Tricks in ASIMON360: Online bus information (EN)
- Video Tutorial: Tips & Tricks in ASIMON360: Custom catalog (DE)
- Video Tutorial: Tips & Tricks in ASIMON360: Custom catalog (EN)
- Video Tutorial: Tips & Tricks in ASIMON360: How to copy slaves and devices (DE)
- Video Tutorial: Tips & Tricks in ASIMON360: How to copy slaves and devices (EN)
- Video Tutorial: Tips & Tricks in ASIMON360: How to deactivate slaves (DE)
- Video Tutorial: Tips & Tricks in ASIMON360: How to deactivate slaves (EN)
Quick Start Guides
- Quick Start Guide: Tips & Tricks: Replacing a defective device (DE)
- Quick Start Guide: Tips & Tricks: Replacing a defective device (EN)
- Quick Start Guide: Tips & Tricks in ASIMON360: Custom catalog (DE)
- Quick Start Guide: Tips & Tricks in ASIMON360: Custom catalog (EN)
- Quick Start Guide: Tips & Tricks in ASIMON360: How to copy slaves and devices (DE)
- Quick Start Guide: Tips & Tricks in ASIMON360: How to copy slaves and devices (EN)
- Quick Start Guide: Tips & Tricks in ASIMON360: How to deactivate ASi modules (DE)
- Quick Start Guide: Tips & Tricks in ASIMON360: How to deactivate ASi modules (EN)
- Quick Start Guide: Tips & Tricks in ASIMON360: Online bus information (DE)
- Quick Start Guide: Tips & Tricks in ASIMON360: Online bus information (EN)
- Quick Start Guide: ASIMON360 Configuration of Safety devices (DE)
- Quick Start Guide: ASIMON360 Configuration of Safety devices (EN)
- Quick Start Guide: ASIMON360 Configuration of Safety devices (PL)
The product has earned the following certifications:
BWU3185
Passive Distributor ASi to 1 x M12 cable socket, angled, 5 poles, depth 19 mm, IP67
» show product detailsBWU3247
Passive Distributor ASi to 1 x M12 cable socket, straight, 5 poles, depth 19 mm, IP67