Safety Monitor

The Safety Monitor enables safe transmission and processing of safety relevant data from safety input modules and safe shut-off of safety output modules remotely over ASi right where the potentially hazardous motion takes place. And always PLe compliant.

Bihl+Wiedemann offers the Safety Monitor for ASi Safety at Work as a stand-alone device for expanding existing ASi circuits with safety modules. For new systems we can provide our ASi-3 resp. ASi-5/ASi-3 gateways with integrated Safety Monitor and interfaces for the most commonly used automation systems using the most efficient method for safely constructing 1 or 2 ASi circuits at the same time. Even large applications with up to 1922 safety I/Os can be implemented with these devices using our “Safe Link over Ethernet” technology by connecting multiple gateways safely over Ethernet/Profinet.

For small applications with three or more safe signals you should consider our Safety Basic Monitor, a compact safety controller without gateway but with configurable status outputs. The module allows for universal expansion and is also ideal as a head station for special safety applications.

 

Filter products

 of  products selected

Bihl+Wiedemann's Choice

The "Bihl+Wiedemann's Choice" range consists exclusively of best-practice products that combine the highest level of user experience, are nearly always in stock in large quantities and can usually be shipped right away. "Bihl+Wiedemann's Choice" items are suitable for almost all standard applications and are also very attractively priced thanks to the quantities produced. We have introduced the "Bihl+Wiedemann's Choice" labeling to provide our customers with a quick decision-making aid while clearly highlighting what advantages the respective product has for the customer.

B+W's Choice
    Safety Monitor

    The Safety Monitor enables safe transmission and processing of safety relevant data from safety input modules and safe shut-off of safety output modules remotely over ASi right where the potentially hazardous motion takes place. And always PLe compliant.

    Bihl+Wiedemann offers the Safety Monitor for ASi Safety at Work as a stand-alone device for expanding existing ASi circuits with safety modules. For new systems we can provide our ASi-3 resp. ASi-5/ASi-3 gateways with integrated Safety Monitor and interfaces for the most commonly used automation systems using the most efficient method for safely constructing 1 or 2 ASi circuits at the same time. Even large applications with up to 1922 safety I/Os can be implemented with these devices using our “Safe Link over Ethernet” technology by connecting multiple gateways safely over Ethernet/Profinet.

    For small applications with three or more safe signals you should consider our Safety Basic Monitor, a compact safety controller without gateway but with configurable status outputs. The module allows for universal expansion and is also ideal as a head station for special safety applications.

     

    Figure
    Fieldbus interface
    Safety communication
    Inputs Safety, SIL 3, Cat. 4
    Outputs Safety, SIL 3, cat. 4
    ASi-5/ASi-3
    Number of ASi networks, number of ASi Master
    Integrated decoupling, ASi current measurement in the gateway
    Article No.
    PROFINET, OPC UA
    PROFIsafe (F-CPU) + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    PROFIsafe (F-CPU) + Safe Link
    no local safe input
    no local safe output
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    PROFIsafe (F-CPU) + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    PROFIsafe (F-CPU) + Safe Link
    no local safe input
    no local safe output
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    PROFINET, OPC UA
    Safe Link
    no local safe input
    no local safe output
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    PROFINET
    PROFIsafe (F-CPU) + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFINET
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFINET
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    PROFINET
    PROFIsafe (F-CPU)
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    EtherNet/IP + ModbusTCP, OPC UA
    CIP Safety over EtherNet/IP + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    EtherNet/IP + ModbusTCP, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    EtherNet/IP + ModbusTCP, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    EtherNet/IP + ModbusTCP, OPC UA
    CIP Safety over EtherNet/IP + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    EtherNet/IP + ModbusTCP
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    EtherNet/IP + ModbusTCP
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    no, max. 8 A/ASi network, redundant supply
    EtherNet/IP + ModbusTCP
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    EtherCAT, OPC UA
    FSoE + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    EtherCAT, OPC UA
    FSoE + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    EtherCAT, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    EtherCAT
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    EtherCAT
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    BACnet/IP, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 8 A/ASi network
    BACnet/IP, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    no, max. 8 A/ASi network, redundant supply
    POWERLINK, OPC UA
    openSAFETY over POWERLINK + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    POWERLINK, OPC UA
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    POWERLINK
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    POWERLINK
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    Sercos, OPC UA
    safe Schneider drives over Sercos + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Sercos, OPC UA
    CIP Safety over Sercos + Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Sercos, OPC UA
    CIP Safety over Sercos + Safe Link
    no local safe input
    no local safe output
    ASi-5 + ASi-3 compatible
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFIBUS
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    PROFIBUS
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    PROFIBUS
    PROFIsafe (F-CPU)
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    CANopen
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    CC-Link
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    DeviceNet
    Safe Link
    3 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    ASi monitors
    Safe Link
    3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz)
    2 release circuits, 2 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply
    ASi monitors
    -
    4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
    2 release circuits, 2 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply
    ASi monitors
    -
    4 x 2 channels, inputs 3+4, compatible as replacement with consortial monitor
    2 release circuits, 2 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, no ASi Master, ASi Monitor
    no, max. 8 A/ASi network
    ASi monitors
    -
    4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
    2 release circuits, 2 x electronic safe outputs
    ASi-3 compatible
    1 ASi network, 1 ASi-3 Master
    yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply