Logo Bihl+Wiedemann GmbH

Gateways

Additional attributes:

    Figure
    Type
    Model
    Protection rating
    Fieldbus interface
    Number of AS-i networks, number of AS-i Master
    1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies
    Diagnostic and configuration interface
    Recognition of duplicate AS-i addresses
    AS-i fault detector
    Programming in C
    Inputs digital, EDM
    Inputs Safety, SIL 3, Cat. 4
    Inputs safety, expandable to
    Outputs Safety, SIL 3, cat. 4
    Safety outputs, independent according to SIL 3, expandable to
    Safety communication
    Article No.
    24 Volt AS-i Gateway
    Gateway
    IP20
    PROFIBUS
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    -
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    24 Volt AS-i Gateway
    Gateway
    IP20
    PROFINET
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet fieldbus
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    24 Volt AS-i Gateway
    Gateway
    IP20
    EtherNet/IP + Modbus/TCP
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet fieldbus
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    24 Volt AS-i Gateway
    Gateway
    IP20
    EtherCAT
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet fieldbus
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    24 Volt AS-i Gateway
    Gateway
    IP20
    POWERLINK
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    -
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    24 Volt AS-i Gateway
    Gateway
    IP20
    CC-Link
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    -
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    PROFIBUS AS-i
    Gateway
    IP20
    PROFIBUS
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    PROFIBUS AS-i
    Gateway
    IP20
    PROFIBUS
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    Ethernet diagnostic
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    PROFIBUS AS-i
    Gateway
    IP20
    PROFIBUS
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network
    -
    no
    yes
    no
    -
    -
    -
    -
    -
    -
    PROFIBUS AS-i
    Gateway
    IP20
    PROFIBUS
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    PROFIBUS AS-i
    Gateway
    IP20
    PROFIBUS
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    PROFIBUS AS-i
    Gateway
    IP20
    PROFIBUS
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    -
    no
    yes
    no
    -
    -
    -
    -
    -
    -
    Starter Kits
    Gateway
    IP20
    PROFIBUS
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    PROFIBUS AS-i Basic
    Gateway
    IP20
    PROFIBUS
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    -
    no
    yes
    no
    -
    -
    -
    -
    -
    -
    PROFINET AS-i
    Gateway
    IP20
    PROFINET
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    PROFINET AS-i
    Gateway
    IP20
    PROFINET
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    Ethernet fieldbus
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    PROFINET AS-i
    Gateway
    IP20
    PROFINET
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    Ethernet fieldbus
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    PROFINET AS-i
    Gateway
    IP20
    PROFINET
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    EtherNet/IP + ModbusTCP AS-i
    Gateway
    IP20
    EtherNet/IP + Modbus/TCP
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + RS 232
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    EtherNet/IP + ModbusTCP AS-i
    Gateway
    IP20
    EtherNet/IP + Modbus/TCP
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    Ethernet fieldbus + RS 232
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    EtherNet/IP + ModbusTCP AS-i
    Gateway
    IP20
    EtherNet/IP + Modbus/TCP
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    Ethernet fieldbus + RS 232
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    BACnet/IP AS-i
    Gateway
    IP20
    BACnet/IP
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    DeviceNet AS-i
    Gateway
    IP20
    DeviceNet
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    DeviceNet AS-i
    Gateway
    IP20
    DeviceNet
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    DeviceNet AS-i
    Gateway
    IP20
    DeviceNet
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    ControlLogix AS-i
    Gateway
    IP20
    ControlLogix
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network
    RS 232
    no
    no
    no
    -
    -
    -
    -
    -
    -
    ControlLogix AS-i
    Gateway
    IP20
    complete set ControlLogix
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network
    RS 232
    no
    no
    no
    -
    -
    -
    -
    -
    -
    Compact- / MicroLogix AS-i
    Gateway
    IP20
    CompactLogix, MicroLogix1500
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    RS 232
    no
    no
    no
    -
    -
    -
    -
    -
    -
    Compact- / MicroLogix AS-i
    Gateway
    IP20
    complete set CompactLogix, MicroLogix1500
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    RS 232
    no
    no
    no
    -
    -
    -
    -
    -
    -
    EtherCAT AS-i
    Gateway
    IP20
    EtherCAT
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    EtherCAT AS-i
    Gateway
    IP20
    EtherCAT
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    EtherCAT AS-i
    Gateway
    IP20
    EtherCAT
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    CC-Link AS-i
    Gateway
    IP20
    CC-Link
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    -
    no
    yes
    no
    -
    -
    -
    -
    -
    -
    POWERLINK AS-i
    Gateway
    IP20
    POWERLINK
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    Ethernet diagnostic
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    POWERLINK AS-i
    Gateway
    IP20
    POWERLINK
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    -
    -
    -
    -
    -
    -
    CANopen AS-i
    Gateway
    IP20
    CANopen
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    CANopen AS-i
    Gateway
    IP20
    CANopen
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    CANopen AS-i
    Gateway
    IP20
    CANopen
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    RS 485 Modbus AS-i
    Gateway
    IP20
    Modbus/RTU; RS 485
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    RS 485 Modbus AS-i
    Gateway
    IP20
    Modbus/RTU; RS 485
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    RS 485 Modbus AS-i
    Gateway
    IP20
    Modbus/RTU; RS 485
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    RS 232
    yes
    yes
    no
    -
    -
    -
    -
    -
    -
    RS 232 AS-i
    Gateway
    IP20
    RS 232
    1 AS-i network, 1 AS-i Master
    no, max. 8 A/AS-i network
    -
    no
    yes
    no
    -
    -
    -
    -
    -
    -
    Safety, PROFIBUS
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, PROFIBUS
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    4
    -
    max. 62 x 2 channels, max. 1922 in max. configuration
    4 release circuits; 2 x relay, 2 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, PROFIBUS
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    no
    4
    -
    max. 62 x 2 channels
    4 release circuits; 2 x relay, 2 x fast electronic safe outputs
    max. 16
    -
    Safety, PROFIBUS
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    2 AS-i networks, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    no
    4
    -
    max. 62 x 2 channels
    4 release circuits; 2 x relay, 2 x fast electronic safe outputs
    max. 16
    -
    Safety, PROFIBUS
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    2 AS-i networks, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    no
    4
    -
    max. 62 x 2 channels
    2 release circuits; 2 x 2 relay
    max. 16
    -
    Safety, PROFIBUS
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    Starter Kits
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    4
    -
    max. 62 x 2 channels, max. 1922 in max. configuration
    4 release circuits; 2 x relay, 2 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, PROFINET
    Gateway with integrated Safety Monitor
    IP20
    PROFINET
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, PROFINET
    Gateway with integrated Safety Monitor
    IP20
    PROFINET
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + RS 232
    yes
    yes
    optional
    4
    -
    max. 62 x 2 channels, max. 1922 in max. configuration
    4 release circuits; 2 x relay, 2 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, PROFINET
    Gateway with integrated Safety Monitor
    IP20
    PROFINET
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, PROFINET
    Gateway with integrated Safety Monitor
    IP20
    PROFINET
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    Starter Kits
    Gateway with integrated Safety Monitor
    IP20
    PROFINET
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Starter Kits
    Gateway with integrated Safety Monitor
    IP20
    PROFINET
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    PROFIsafe, PROFIBUS
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels
    6 release circuits; 6 x fast electronic safe outputs
    max. 31
    PROFIsafe (F-CPU) + ASIMON program
    PROFIsafe, PROFIBUS
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    4
    -
    max. 62 x 2 channels
    4 release circuits; 2 x relay, 2 x fast electronic safe outputs
    max. 16
    PROFIsafe (F-CPU) + ASIMON program
    PROFIsafe, PROFIBUS
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    2 AS-i networks, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    4
    -
    max. 62 x 2 channels
    4 release circuits; 2 x relay, 2 x fast electronic safe outputs
    max. 16
    PROFIsafe (F-CPU) + ASIMON program
    PROFIsafe, PROFIBUS
    Gateway with integrated Safety Monitor
    IP20
    PROFIBUS
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    RS 232
    yes
    yes
    no
    -
    -
    max. 31 x 2 channels
    -
    max. 16
    PROFIsafe (F-CPU)
    PROFIsafe, PROFINET
    Gateway with integrated Safety Monitor
    IP20
    PROFINET
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 64, max. 1984 in max. configuration
    PROFIsafe (F-CPU) + ASIMON program + Safe Link
    PROFIsafe, PROFINET
    Gateway with integrated Safety Monitor
    IP20
    PROFINET
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    -
    -
    max. 62 x 2 channels
    -
    max. 16
    PROFIsafe (F-CPU) + ASIMON program
    PROFIsafe, PROFINET
    Gateway with integrated Safety Monitor
    IP20
    PROFINET
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + RS 232
    yes
    yes
    optional
    4
    -
    max. 62 x 2 channels
    4 release circuits; 2 x relay, 2 x fast electronic safe outputs
    max. 16
    PROFIsafe (F-CPU) + ASIMON program
    PROFIsafe, PROFINET
    Gateway with integrated Safety Monitor
    IP20
    PROFINET
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels
    6 release circuits; 6 x fast electronic safe outputs
    max. 31
    PROFIsafe (F-CPU) + ASIMON program
    Safety, Sercos
    Gateway with integrated Safety Monitor
    IP20
    Sercos
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 64, max. 1984 in max. configuration
    CIP Safety over Sercos + Safe Link
    Safety, Sercos
    Gateway with integrated Safety Monitor
    IP20
    Sercos
    2 AS-i networks, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 64, max. 1984 in max. configuration
    safe Schneider drives over Sercos + Safe Link
    Safety, Sercos
    Gateway with integrated Safety Monitor
    IP20
    Sercos
    2 AS-i networks, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    4
    -
    max. 62 x 2 channels, max. 1922 in max. configuration
    4 release circuits; 2 x relay, 2 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, EtherNet/IP + ModbusTCP
    Gateway with integrated Safety Monitor
    IP20
    EtherNet/IP + Modbus/TCP
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels
    6 release circuits; 6 x fast electronic safe outputs
    max. 64
    CIP Safety over EtherNet/IP
    Safety, EtherNet/IP + ModbusTCP
    Gateway with integrated Safety Monitor
    IP20
    EtherNet/IP + Modbus/TCP
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, EtherNet/IP + ModbusTCP
    Gateway with integrated Safety Monitor
    IP20
    EtherNet/IP + Modbus/TCP
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    4
    -
    max. 62 x 2 channels, max. 1922 in max. configuration
    4 release circuits; 2 x relay, 2 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, EtherNet/IP + ModbusTCP
    Gateway with integrated Safety Monitor
    IP20
    EtherNet/IP + Modbus/TCP
    2 AS-i networks, 2 AS-i Masters
    no, max. 8 A/AS-i network, redundant supply
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, EtherNet/IP + ModbusTCP
    Gateway with integrated Safety Monitor
    IP20
    EtherNet/IP + Modbus/TCP
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    Safety, DeviceNet
    Gateway with integrated Safety Monitor
    IP20
    DeviceNet
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    Safety, EtherCAT
    Gateway with integrated Safety Monitor
    IP20
    EtherCAT
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 64, max. 1984 in max. configuration
    FSoE + Safe Link
    Safety, EtherCAT
    Gateway with integrated Safety Monitor
    IP20
    EtherCAT
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, EtherCAT
    Gateway with integrated Safety Monitor
    IP20
    EtherCAT
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    FSoE + Safe Link
    Safety, EtherCAT
    Gateway with integrated Safety Monitor
    IP20
    EtherCAT
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    Safety, POWERLINK
    Gateway with integrated Safety Monitor
    IP20
    POWERLINK
    2 AS-i networks, 2 AS-i Masters
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    Safety, POWERLINK
    Gateway with integrated Safety Monitor
    IP20
    POWERLINK
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    Safety, CANopen
    Gateway with integrated Safety Monitor
    IP20
    CANopen
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    Safety, CC-Link
    Gateway with integrated Safety Monitor
    IP20
    CC-Link
    1 AS-i network, 1 AS-i Master
    yes, max. 4 A/AS-i network
    Ethernet diagnostic
    yes
    yes
    optional
    6
    3 x 2 channels
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits; 6 x fast electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link