BWU3115ASi Motor Module, IP67, M12 for Lenze Smart motor, 4I/3O
Product description
ASi Motor Module in IP67, with 4 x M12 sockets for 1 x Lenze Smart motor, 4 digital inputs, 3 digital outputs, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 4 x M12 sockets, 5 poles, ASi connection via profile cable and piercing technology, 1 AB address
2 x M12 connections compatible with Lenze Smart Motor
2 x M12 connections for upt to 3 additional sensors
The substructure module is not included in the scope of delivery.
Technical data
Drive
"SEW MOVIMOT®": Motor module to control geared motors with frequency inverters.
"NORD": Motor module to control geared motors with frequency inverters.
Brake chopper for 24 V motorized rollers: For limiting the voltage feedback, suitable for all 24 V motorized rollers. | Lenze Smart Motor | ||||||||||||||||||||
Number of Drives | 1 | ||||||||||||||||||||
Inputs digital | 3 | ||||||||||||||||||||
Input voltage (sensor supply)
inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | out of AUX | ||||||||||||||||||||
Output voltage (actuator supply)
Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | out of AUX | ||||||||||||||||||||
Connection
PUR line, oil resistant. Further connection options are available on request.
| 4 x M12 sockets, 5 poles | ||||||||||||||||||||
Round cable
Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled. In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted. | no | ||||||||||||||||||||
ASi address
AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed. | 1 AB address |