Building Automation

The benefits of AS-Interface – such as the simple, cost-saving installation and high degree of flexibility – have now established themselves in building automation. Numerous companies are already using the AS-i installation system, for example for controlling fire and smoke dampers, shutter drives or heating and cooling ceilings using analog output modules. Damper drives with flow regulators can be connected to the controller through the MP-Bus gateway. It is also possible to process EnOcean signals from wireless pushbuttons and sensors over AS-i. During your planning and application implementation phases we can be at your side and are open to application-specific special solutions.

 

AS-i Gateways in Stainless Steel

  • BACnet
  • PROFINET
  • PROFIBUS
  • Modbus RTU
  • EtherNet/IP + Modbus TCP
Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.


PROFIBUS AS-i gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS AS-i IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET AS-i gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus/TCP AS-i gateway: interface for an EtherNet/IP+ Modbus/TCP fieldbus

BACnet/IP AS-i gateway: interface for a BACnet/IP fieldbus
DeviceNet AS-i gateway: interface for a DeviceNet fieldbus
ControlLogix AS-i gateway: interface for the ControlLogix backplane

Compact-/MicroLogix AS-i gateway: interface for the Compact-/MicroLogix backplane
EtherCat AS-i gateway: interface for an EtherCat fieldbus

POWERLINK AS-i gateway: interface for an POWERLINK fieldbus
CC-Link AS-i gateway:
interface for a CC-Link fieldbus
CANopen AS-i gateway: interface for a CANopen fieldbus
RS 485 Modbus AS-i gateway: interface for a Modbus/RTU; RS 485 fieldbus

Fieldbus interface

Standard devices

"Single Master":

1 AS-i network, 1 AS-i Master.

"Double Master":

2 AS-i networks, 2 AS-i Masters.

Safety devices

"Single Master":
1 AS-i network, 1 AS-i Master.

"Double Master":
2 AS-i networks, 2 AS-i Masters.

"Optional AS-i Safety coupling circuit":
2 AS-i networks, 1 AS-i Master.

Number of AS-i networks, number of AS-i Master

"yes, max. 4 A/AS-i network":
Cost-effective power for 2 AS-i networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/AS-i network, redundant supply":
1 AS-i power supply per AS-i network. Gateway is powered in normal operation from one of the two AS-i power supplies.

Should one AS-i power supply fail, switching to the other AS-i power supply allows all the diagnostics functions to be maintained and the unaffected AS-i network continues to operate.

"no, max. 8 A/AS-i network":

1 AS-i power supply per AS-i network.

1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies

"USB":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to AS-i Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two AS-i slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate AS-i addresses

Checks the AS-i line for interference effects such as noise, external voltages, ...

AS-i fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU3356 BACnet/IP AS-i Gateway IP20 BACnet/IP 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet fieldbus + Ethernet diagnostic yes yes optional
BWU1642 RS 485 Modbus AS-i Gateway IP20 Modbus/RTU; RS 485 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply RS 232 yes yes no
BWU1641 RS 485 Modbus AS-i Gateway IP20 Modbus/RTU; RS 485 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network RS 232 yes yes no
BWU2239 PROFINET AS-i Gateway IP20 PROFINET 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet fieldbus + RS 232 yes yes optional
BWU2380 EtherNet/IP + ModbusTCP AS-i Gateway IP20 EtherNet/IP + Modbus/TCP 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet fieldbus + RS 232 yes yes optional
BWU2379 EtherNet/IP + ModbusTCP AS-i Gateway IP20 EtherNet/IP + Modbus/TCP 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network Ethernet fieldbus + RS 232 yes yes optional
BWU2545 PROFIBUS AS-i Gateway IP20 PROFIBUS 2 AS-i networks, 2 AS-i Masters no, max. 8 A/AS-i network, redundant supply Ethernet diagnostic yes yes optional
BWU2544 PROFIBUS AS-i Gateway IP20 PROFIBUS 1 AS-i network, 1 AS-i Master no, max. 8 A/AS-i network Ethernet diagnostic yes yes optional

Power Supplies

Figure

"AS-i power supply":

Suitable for all AS-i Gateways and Safety Monitors from Bihl + Wiedemann.

"30 V power supply":

Suitable for all AS-i Gateways and Safety Monitors with specifications "1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies" and for all 24 Volt AS-i Gateways.


"AS-i power supply decoupling unit":

Supply of 2 AS-i networks out of 1 power supply. Applicable with double masters without integrated data decoupling.

"Power decoupling unit":

Take up to 1,2 A out of AS-i. In combination with an AS-i Repeater: decouples 1,2 A from AS-i Segment B and supplies Segment A with 1,2 A.

Power supply
Operating voltage Output current

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BW1997 AS-i power supply 115 V AC / 230 V AC, power supply with range switch 8 A IP20
BW1649 AS-i power supply 90 V AC ... 265 V AC, wide range supply 4 A IP20
BW2255 AS-i power supply 115 V AC ... 250 V AC 1,8 A IP20

Fire/smoke dampers

  • Controlling ventilation, fire, smoke dampers
  • Requirements for Germany and EC
  • Requirements for Switzerland (IG-BSK)
  • 24V/230V relay
  • EN 6206 SIL2
Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from AS-i. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific AS-i Slave profiles.

AS-i address
Article No.
BW2482 ventilation damper module ventilation, fire, smoke dampers - IP54 4 2 x electronic out of AS-i out of AS-i 1 Single Slave
BW2028 ventilation damper module ventilation, fire, smoke dampers - IP54 4 2 x electronic out of AS-i out of AS-i 1 Single Slave
BW2029 ventilation damper module ventilation, fire, smoke dampers - IP54 3 2 x electronic out of AUX out of AUX 1 AB Slave
BW2080 ventilation damper module ventilation, fire, smoke dampers (Switzerland) - IP54 3 2 x electronic out of AS-i out of AS-i 1 AB Slave
BW3005 ventilation damper module, Safety ventilation, fire, smoke dampers - IP54 4 2 x electronic out of AS-i out of AS-i 1 Single Slave
BW3009 ventilation damper module ventilation, fire, smoke dampers (230 V relay) - IP54 4 4 x relay out of AS-i - 1 AB Slave
BW3010 ventilation damper module ventilation, fire, smoke dampers (230 V relay) - IP54 4 + 2 x fusible link 2 x relay out of AS-i - 1 AB Slave
BW3011 ventilation damper module ventilation, fire, smoke dampers (230 V relay) - IP54 4 2 x relay out of AS-i - 1 AB Slave
BW2480 ventilation damper module ventilation, fire, smoke dampers surface-mounted box IP54 4 - out of AS-i - 1 AB Slave
BW2701 I/O for VAV boxes I/O modules surface-mounted box IP54 - - selectable, out of AS-i or out of AUX, Default out of AS-i selectable, out of AS-i or out of AUX, default out of AS-i 1 Single Slave
BW3412 I/O for manual call points I/O modules surface-mounted box IP54 4 4 x electronic out of AUX out of AUX 1 AB Slave

Heating, Ventilating and Air Conditioning & Building Automation in General

  • Shutter modules
  • Heating/air conditioning
  • EnOcean
  • MP Bus
Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital Inputs analog Outputs analog

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from AS-i. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)
Controlling heating/air conditioning Article No.
BW2114 shutter module controlling 230 V shutters - IP54 8 4 x relay - - out of AS-i - -
BW2536 heating/air conditioning (24 V AC/DC) heating/air conditioning, 0 … 10 V, (climate control ceilings) surface-mounted box IP54 - 2 x electronic - 2 x 0 … 10 V out of AS-i selectable, out of AS-i or out of AUX (AC/DC), default out of AS-i Controlling heating and climate control ceilings
BW2537 heating/air conditioning (24 V AC/DC) analog inputs 0 ... 10 V (temperature CO2 etc.) + digital inputs surface-mounted box IP54 2 - 2 x 0 ... 10 V - selectable, out of AS-i or out of AUX (AC/DC), default out of AS-i - Recording of analog values
BW2138 Heating/air conditioning heating/air conditioning (valves) surface-mounted box IP54 - 4 x electronic - - - out of AUX Controlling valves and heating valves
BW2375 connection to EnOcean connection to EnOcean white IP40 31 x 4 EnOcean 8 x 6 EnOcean out of AS-i - -
BW2473 connection to EnOcean connection to EnOcean black IP40 31 x 4 EnOcean 8 x 6 EnOcean out of AS-i - -
BW2580 connection to EnOcean, surface-mounted box connection to EnOcean surface-mounted box IP40 31 x 4 EnOcean 8 x 6 EnOcean out of AS-i - -
BW2406 connection to MP-Bus connection to MP-Bus - IP54 - - - - out of AS-i out of AUX -
BWU1232 IP65, 3 x PG I/O modules 3 x PG IP65 - - 2 x 4 … 20 mA - selectable, out of AS-i or out of AUX, Default out of AS-i - -
BWU1233 IP65, 3 x PG I/O modules 3 x PG IP65 - - 2 x 0 ... 10 V - selectable, out of AS-i or out of AUX, Default out of AS-i - -
BWU1234 IP65, 3 x PG I/O modules 3 x PG IP65 - - - 2 x 0 ... 20 mA - selectable, out of AS-i or out of AUX, default out of AS-i -
BWU1235 IP65, 3 x PG I/O modules 3 x PG IP65 - - - 2 x 0 … 10 V - selectable, out of AS-i or out of AUX, default out of AS-i -
BWU1254 IP65, 8 x PG I/O modules 8 x PG IP65 - - 4 x Pt100 - out of AS-i - -
BWU1509 IP65, 8 x PG I/O modules 8 x PG IP65 - - 4 x Pt1000 - out of AS-i - -
BWU1933 IP20, 25 mm x 105 mm, 6 x COMBICON I/O modules 6 x COMBICON IP20 - - 4 x thermocouple type J - out of AS-i - -
BWU2243 IP20, 25 mm x 105 mm, 6 x COMBICON I/O modules 6 x COMBICON IP20 - - 4 x thermocouple type K - out of AS-i - -
BW2388 PCB, flush-mounted module, coated I/O modules coated IP00, thick coated 4 - - - out of AS-i - -
BW2128 PCB building automation I/O modules OEM board IP00 4 3 x electronic - - out of AUX out of AUX -

Active Distributors AS-i, IP67/IP20

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from AS-i. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible

status of in- and outputs is indicated by LEDs. In addition to that, both AS-i LEDs (PWR green and FAULT red) show as usual regarding the AS-i Slaves- the status of the AS-i Slaves. Uaux is indicated by a green LED.

LED status display

PUR line, oil ans abrasion resistant, appropriate for conveyor chains. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

Under normal conditions (no bus termination or repeater), the permissible total length of the AS-i segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (AS-i slaves) however only the one AS-i profile cable is counted.

Round cable

the connection to AS-i as well to AUX (auxiliary 24 V power) is made via yellow resp. black AS-i profile cable with piercing technology or via M12 socket (in IP20 via clamps).

AS-i connection

AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific AS-i Slave profiles.

AS-i address
Article No.
BW3317 Active distributor AS-i depth: 35 mm IP67 4 4 x electronic out of AS-i out of AUX yes, depth: 35 mm yes 2 x round cables/connecting wires 1 m AS-i profile cable 1 AB Slave
BW3326 Active distributor AS-i depth: 35 mm IP67 4 4 x electronic out of AS-i out of AS-i yes, depth: 35 mm yes 2 x round cables/connecting wires 1 m AS-i profile cable 1 AB Slave
BW3300 Active distributor AS-i depth: 19 mm IP67 - 4 x electronic - out of AUX yes, depth: 19 mm yes 1 x round cable/connecting wires 1 m AS-i profile cable 1 AB Slave
BW3349 Active distributor AS-i depth: 19 mm IP20 4 - out of AUX - yes, depth: 19 mm yes 8 x push in terminals no AS-i profile cable 1 AB Slave
BW3414 Active distributor AS-i depth: 19 mm IP20 3 1 x electronic out of AUX out of AUX yes, depth: 19 mm yes 8 x push in terminals no AS-i profile cable 1 AB Slave
BW3342 Active distributor AS-i depth: 19 mm IP20 - 4 x electronic - out of AUX yes, depth: 19 mm yes 8 x push in terminals no AS-i profile cable 1 AB Slave

I/O Modules for installation in control cabinets/decentralized control cabinets, IP20

  • Robust, Stainless Steel in IP20
  • Cost efficient solution in IP20, 22,5 mm
Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from AS-i. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific AS-i Slave profiles.

AS-i address
Article No.
BW1926 Stainless Steel in IP20, depth: 45 mm I/O modules depth: 45 mm IP20 4 4 x relay out of AS-i - 1 Single Slave
BW1808 Stainless Steel in IP20, depth: 45 mm I/O modules depth: 45 mm IP20 4 3 x relay out of AS-i - 1 AB Slave
BWU1907 Stainless Steel in IP20, depth: 45 mm I/O modules depth: 45 mm IP20 4 4 x electronic out of AUX out of AUX 1 AB Slave
BWU2565 Stainless Steel in IP20, depth: 45 mm I/O modules depth: 45 mm IP20 4 4 x electronic out of AUX out of AUX 1 Single Slave
BWU2077 Stainless Steel in IP20, depth: 45 mm I/O modules depth: 45 mm IP20 8 - out of AUX - 2 AB Slaves
BWU2078 Stainless Steel in IP20, depth: 45 mm I/O modules depth: 45 mm IP20 - 8 x electronic - out of AUX 2 AB Slaves
BW2555 Stainless Steel in IP20, depth: 90 mm I/O modules depth: 90 mm IP20 4 4 x relay out of AS-i - 1 Single Slave
BWU2556 Stainless Steel in IP20, depth: 90 mm I/O modules depth: 90 mm IP20 8 - out of AUX - 2 AB Slaves
BWU3559 IP20, 22,5 mm x 92 mm, 4 x COMBICON I/O modules 4 x COMBICON IP20 4 4 x electronic out of AUX out of AUX 1 AB Slave
BWU2723 IP20, 22,5 mm x 114 mm, 4 x COMBICON I/O modules 3 x COMBICON IP20 4 - out of AUX - 1 AB Slave
BWU1938 IP20, 22,5 mm x 114 mm, 4 x COMBICON I/O modules 4 x COMBICON IP20 4 4 x electronic out of AUX out of AUX 1 AB Slave
BWU2759 IP20, 22,5 mm x 114 mm, 4 x COMBICON I/O modules 4 x COMBICON IP20 4 4 x electronic out of AUX out of AUX 1 Single Slave
BWU2721 IP20, 22,5 mm x 114 mm, 4 x COMBICON I/O modules 4 x COMBICON IP20 8 - out of AUX - 2 AB Slaves
BWU2490 IP20, 22,5 mm x 114 mm, 6 x COMBICON I/O modules 6 x COMBICON IP20 8 8 x electronic out of AUX out of AUX 2 AB Slaves
BWU2800 IP20, 22,5 mm x 114 mm, 6 x COMBICON I/O modules 6 x COMBICON IP20 8 8 x electronic out of AUX out of AUX 2 Single Slaves

I/O Modules for installation on ceiling, walls and floor, IP54

Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by AS-i or by AUX (auxiliary 24 V power). If supplied by AS-i, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from AS-i. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific AS-i Slave profiles.

AS-i address
Article No.
BW2139 I/O in surface-mounted box I/O modules surface-mounted box IP54 4 3 x electronic out of AUX out of AUX 1 AB Slave
BW2137 I/O in surface-mounted box I/O modules surface-mounted box IP54 4 4 x electronic out of AUX out of AUX 1 AB Slave
BW2175 I/O in surface-mounted box I/O modules surface-mounted box IP54 4 4 x electronic out of AUX out of AUX 1 Single Slave
BW2466 I/O in surface-mounted box I/O modules surface-mounted box IP54 4 - out of AUX - 1 Single Slave

Passive Distributors AS-i, IP67

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible

PUR line, oil ans abrasion resistant, appropriate for conveyor chains. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

Under normal conditions (no bus termination or repeater), the permissible total length of the AS-i segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (AS-i slaves) however only the one AS-i profile cable is counted.

Round cable
Profile cable connection Article No.
BW3186 Passive distributor AS-i depth: 19 mm IP67 yes, depth: 19 mm 1 x round cable/connecting wires 0,25 m 2 x AS-i
BW3524 Passive distributor AS-i depth: 19 mm IP67 yes, depth: 19 mm 1 x round cable/connecting wires 5 m 2 x AS-i
BW3157 Passive distributor AS-i depth: 19 mm IP67 yes, depth: 19 mm profile cable branch no 2 x AS-i
BWU1975 Passive distributor AS-i depth: 19 mm IP67 yes, depth: 19 mm profile cable branch no 2 x AS-i