Logo Bihl+Wiedemann GmbH

I/O Modules

Bihl+Wiedemann offers a wide variety of AS-i modules. These are equipped with a various number of in- and outputs offering the right module for any application. Nor are special requirements a problem, such as sensors powered from AS-i or external voltage (AUX). The large selection of analog modules reflects the commitment to offering the right module for any application or analog signal. Deserving special mention are high-resolution 16-bit analog modules or modules for especially fast transmission of the analog values.

 

EXTREME product line for ASi: Digital Modules ASi, IP67, M12

  • 100% protection against moisture
  • High resistance to salt spray
  • High corrosion resistance to chemically active substances
  • Assured functionality at extreme temperatures from – 40 °C to 70 °C
  • Shock resistant to 30g (11 ms)
  • Vibration rated for a frequency of 5...500 Hz at an amplitude of 50 mmpp / 6g
Figure Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

either as a single–wiring, Y–wiring or mixed-wiring.

M12 (5 poles)
Single-wiringY-wiringMixed-wiring


M8 (3 poles)
Single wiring

 

M8/M12 wiring

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

the connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Article No.
BWU31448 x M12IP6744 x electronicYout of ASiout of AUX8 x M12 sockets, 5 polesASi profile cable1 AB Slave

 

Digital Modules ASi, IP67, M12

  • IP67, M12: 2 x 2 connectors for profile cable
  • 2color LEDs per output, state yellow, overload red (optional)
Figure Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital Inputs analog

either as a single–wiring, Y–wiring or mixed-wiring.

M12 (5 poles)
Single-wiringY-wiringMixed-wiring


M8 (3 poles)
Single wiring

 

M8/M12 wiring

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

the connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Article No.
BWU34564 x M12IP6722 x electronic-Yout of ASiout of AUX4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU35394 x M12IP6722 x electronic, special ASi bit assignment-Yout of ASiout of AUX4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU37754 x M12IP6722 x electronic, special ASi bit assignment-Yout of ASiout of AUX4 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU31414 x M12IP6722 x electronic-Singleout of ASiout of AUX4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU35174 x M12IP6722 x electronic-Singleout of ASiout of AUX4 x M12 sockets, 5 polesASi via M121 AB Slave
BWU25524 x M12IP674--Yout of ASi-4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU30774 x M12IP674--Yout of ASi-4 x M12 sockets, 5 polesASi via M121 AB Slave
BWU26204 x M12IP674--Singleout of ASi-4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU35564 x M12IP674--Singleout of ASi-4 x M12 sockets, 5 polesASi profile cable1 AB Slave S-0.A.7.0
BWU34574 x M12IP674--Singleout of ASi-4 x M12 sockets, 5 polesASi via M121 AB Slave
BWU27254 x M12IP674--Singleout of AUX-4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU27674 x M12IP6742 x electronic-Mixedout of AUXout of AUX4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU33754 x M12IP6743 x electronic-Yout of ASiout of AUX4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU24874 x M12IP6744 x electronic-Yout of ASiout of AUX4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU30324 x M12IP6744 x electronic-Yout of AUXout of AUX4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU25474 x M12IP6744 x electronic-Mixedout of AUXout of AUX4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU32404 x M12IP6744 x electronic-Mixedout of ASiout of ASi4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU27134 x M12IP67-4 x electronic-Y-out of AUX4 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU25944 x M12IP67-4 x electronic-Y-out of AUX4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU27284 x M12IP67-4 x electronic-Y-out of AUX, 2 A per output4 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU38028 x M12IP678--Singleout of ASi-8 x M12 sockets, 5 polesASi profile cable1 ASi-5 Slave
BWU31638 x M12IP6788 x electronic-Yout of ASiout of AUX8 x M12 sockets, 5 polesASi profile cable1 ASi-5 Slave
BWU31648 x M12IP6716--Yout of ASi-8 x M12 sockets, 5 polesASi profile cable1 ASi-5 Slave
BWU31448 x M12IP6744 x electronic-Yout of ASiout of AUX8 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU26268 x M12IP6744 x electronic-Yout of ASiout of AUX8 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU26178 x M12IP6744 x electronic-Singleout of ASiout of AUX8 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU26848 x M12IP6744 x electronic-Singleout of ASiout of AUX8 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU28108 x M12IP6744 x electronic-Singleout of AUXout of AUX8 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU26458 x M12IP6744 x electronic-Singleout of AUXout of AUX8 x M12 sockets, 5 polesASi via M121 AB Slave
BWU35408 x M12IP6744 x electronic-Singleout of ASiout of AUX, 2 A per output8 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU34968 x M12IP6743 x electronic-Singleout of ASiout of AUX, 2 A per output8 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU28538 x M12IP674 x IO-Link Port + 4 x elektronic4 x IO-Link Port-IO-Link Port Class Aout of AUXout of AUX4 x M12 sockets, 5 polesASi profile cable2 Single Slaves
BWU30208 x M12IP674 x IO-Link Port4 x IO-Link Port-IO-Link Port Class Bout of ASioutput voltage out of ASi, actuator supply out of AUX4 x M12 sockets, 5 polesASi profile cable2 Single Slaves
BWU27708 x M12IP678--Yout of AUX-8 x M12 sockets, 5 polesASi profile cable2 AB Slaves
BWU26518 x M12IP678--Yout of ASi-8 x M12 sockets, 5 polesASi profile cable2 AB Slaves
BWU29838 x M12IP678--Singleout of ASi-8 x M12 sockets, 5 polesASi profile cable2 AB Slaves
BWU26198 x M12IP6788 x electronic-Yout of ASiout of AUX8 x M12 sockets, 5 polesASi profile cable2 AB Slaves
BWU26528 x M12IP67-8 x electronic-Y-out of AUX8 x M12 sockets, 5 polesASi profile cable2 AB Slaves
BWU23138 x M12IP6744 x electronic2 x Pt100Signal at pin2/pin4out of AUXout of AUX8 x M12 sockets, 5 polesASi profile cable2 AB Slaves

 

An AS-Interface installation with IP67 digital modules from Bihl+Wiedemann having M12 plug-in connections offers many advantages: There are 2 x 2 connections for the yellow profile cable in the substructure of the module. These enable an clearly organized ASi installation where up to 4 ASi end caps and 2 passive distributors per module can be saved.

(Click to enlarge): ASi Installation with modules from Bihl+Wiedemann (Click to enlarge): ASi Installation with traditional modules

 

 

 

 

 

Digitalmodule ASi: IP67, M8

  • IP67, M8: 2 x 2 connectors for profile cable
  • 2color LEDs per output, state yellow, overload red (optional)
Figure Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

either as a single–wiring, Y–wiring or mixed-wiring.

M12 (5 poles)
Single-wiringY-wiringMixed-wiring


M8 (3 poles)
Single wiring

 

M8/M12 wiring

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

the connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Article No.
BW36618 x M8IP6744 x electronicSingleout of ASiout of AUX8 x M8 sockets, 3 polesASi profile cable1 AB Slave

 

Digital Modules ASi: Active Distributors ASi, IP67/IP20

Figure Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital Inputs Safety, SIL 3, Cat. 4

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

either as a single–wiring, Y–wiring or mixed-wiring.

M12 (5 poles)
Single-wiringY-wiringMixed-wiring


M8 (3 poles)
Single wiring

 

M8/M12 wiring

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi slaves) however only the one ASi profile cable is counted.

Round cable

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible
Profile cable connection

the connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Special function Article No.
BWU3577depth: 35 mmIP6742 x electronic-out of ASiout of ASi6 x M8 cable sockets, straight, 4 poles-input: 0,15 m, output: 0,50 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slaveoptimized to control valves Festo CPE14 / VUVG-L14 via ASi
BWU3555depth: 35 mmIP6744 x electronic-out of ASiout of AUX4 x M8 cable sockets, straight, 4 poles-0,20 myes, depth: 35 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BWU3695depth: 35 mmIP6722 x electronic-out of ASiout of ASi2 x M12 cable sockets, straight, 5 poles + 2 x M8 cable socket, straight, 3 polesSingleinput: 0,20 m, output: 0,40 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slave-
BWU3633depth: 35 mmIP674--out of ASi-4 x M12 cable sockets, straight, 5 polesSingle2 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slave-
BWU3632depth: 35 mmIP674--out of ASi-4 x M12 cable sockets, straight, 5 polesSingle0,30 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slave-
BWU3730depth: 35 mmIP544--out of ASi-4 x M12 cable socket, straight, 5 poles + 1 x ASi addressing cable socketSingleI1 0,35 m, I2 0,25 m, I3 0,15 m, I4 0,05 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slave-
BWU3317depth: 35 mmIP6744 x electronic-out of ASiout of AUX2 x round cables/connecting wires-1 myes, depth: 35 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BW3507depth: 35 mmIP6744 x electronic-out of ASiout of AUX2 x M12 cable sockets, straight, 5 poles-1 myes, depth: 35 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BW3326depth: 35 mmIP6744 x electronic-out of ASiout of ASi2 x round cables/connecting wires-1 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slave-
BWU3374depth: 35 mmIP674--out of ASi-2 x round cables/connecting wires-0,50 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slave-
BWU3534depth: 35 mmIP6714 x electronic-out of ASiout of ASi1 x M12 cable socket, straight, 5 poles + 1 x M12 cable socket, angled, 5 poles-0,30 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slaveto connect Banner K50 Series EZ-Light, type K50L...PQ + Wenglor light curtains Pick-to-Light
BW3500depth: 35 mmIP6744 x electronic-out of ASiout of ASi1 x round cable/connecting wires-5 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slave-
BW3377depth: 35 mmIP6744 x electronic-out of AUXout of AUX1 x M12 cable socket, straight, 8 poles-1 myes, depth: 35 mm1 x ASi, 1 x AUXASi profile cable1 AB Slaveto connect Euchner MGB to ASi
BWU3639depth: 35 mmIP6713 x electronic-out of ASiout of ASi1 x M12 cable socket, angled, 8 poles-0,30 myes, depth: 35 mm1 x ASiASi profile cable1 AB Slaveto connect Banner K50 Series EZ-LIGHT, Typ K50AP...F2Q to ASi
BWU3498depth: 19 mmIP674--out of AUX-2 x M12 cable sockets, straight, 5 polesY0,40 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BWU3497depth: 19 mmIP6722 x electronic-out of AUXout of AUX2 x M12 cable sockets, straight, 5 polesY0,40 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BWU3602depth: 19 mmIP6722 x electronic-out of AUXout of AUX2 x round cables/connecting wires-1 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BW3250depth: 19 mmIP6721 x electronic-out of AUXout of AUX2 x M12 cable sockets, angled, 5 poles1 x Y + 1 x Mixed1 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BWU3400depth: 19 mmIP6722 x electronic-out of ASiout of ASi1 x M12 cable socket, straight, 8 poles-1 myes, depth: 19 mm1 x ASiASi profile cable1 AB Slave-
BWU3564depth: 19 mmIP672--out of AUX-1 x M12 cable socket, angled, 5 polesY1 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BW3300depth: 19 mmIP67-4 x electronic--out of AUX1 x round cable/connecting wires-1 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BWU3487depth: 19 mmIP67-4 x electronic--out of AUX1 x round cable/connecting wires-5 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BW3349depth: 19 mmIP204--out of AUX-8 x push in terminals-noyes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BWU3414depth: 19 mmIP2031 x electronic-out of AUXout of AUX8 x push in terminals-noyes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BWU3342depth: 19 mmIP20-4 x electronic--out of AUX8 x push in terminals-noyes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 AB Slave-
BWU3718depth: 19 mmIP67-2 x electronic1 x 2 channelsout of AUXout of AUX1 x M12 cable socket, straight 8 poles + 1 x M12 cable socket, straight, 5 poles-10 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 Single Slaveto connect Leuze MLC530SPG to ASi
BWU3249depth: 19 mmIP67-1 x electronic1 x 2 channelsout of ASiout of ASi2 x round cables/connecting wires-1 myes, depth: 19 mm1 x ASiASi profile cable1 Single Slave-
BWU3600depth: 19 mmIP67--1 x 2 channelsout of ASi-2 x round cables/connecting wires-10 myes, depth: 19 mm1 x ASiASi profile cable1 Single Slave-
BWU3488depth: 19 mmIP6711 x electronic1 x 2 channelsout of AUXout of AUX1 x M12 cable socket, straight, 8 poles-1 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 Single Slaveto connect Pilz PSENslock, PSENcode to ASi
BWU3565depth: 19 mmIP6711 x electronic1 x 2 channelsout of AUXout of AUX1 x M12 cable socket, straight, 8 poles-1 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 Single Slaveto connect Schmersal AZM400 to ASi
BWU3635depth: 19 mmIP6711 x electronic1 x 2 channelsout of AUXout of AUX1 x M12 cable socket, straight, 8 poles-1 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 Single Slaveto connect Schmersal AZM200 / AZM201 / AZM300 / MZM100 to ASi
BWU3599depth: 19 mmIP67-1 x electronic1 x 2 channelsout of ASiout of ASi1 x round cable/connecting wires-10 myes, depth: 19 mm1 x ASiASi profile cable1 Single Slave-
BWU3248depth: 19 mmIP67-1 x electronic1 x 2 channelsout of ASiout of ASi1 x round cable/connecting wires-1 myes, depth: 19 mm1 x ASiASi profile cable1 Single Slave-
BW3299depth: 19 mmIP67-1 x electronic1 x 2 channelsout of AUXout of AUX1 x M12 cable socket, angled, 5 poles-1 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 Single Slave-
BWU3376depth: 19 mmIP67-1 x electronic1 x 2 channelsout of AUXout of AUX1 x M12 cable socket, straight, 5 poles-1 myes, depth: 19 mm1 x ASi, 1 x AUXASi profile cable1 Single Slaveto connect Euchner MGB to ASi
BWU3373depth: 19 mmIP67--1 x 2 channelsout of ASi-1 x round cable/connecting wires-0,30 myes, depth: 19 mm1 x ASiASi profile cable1 Single Slave-
BWU3553depth: 19 mmIP67--1 x 2 channelsout of ASi-1 x M8 cable socket, straight, 4 poles-0,20 myes, depth: 19 mm1 x ASiASi profile cable1 Single Slaveto connect Sick RE13-SA84 / RE13-SAC / RE23-SAC / RE23-SA84 to ASi
BWU3641depth: 19 mmIP67--1 x 2 channelsout of ASi-1 x M12 cable socket, angled, 5 poles-0,13 myes, depth: 19 mm1 x ASiASi profile cable1 Single Slave-
BWU3413depth: 19 mmIP67--1 x 2 channelsout of ASi-1 x M12 cable socket, angled, 5 poles-1 myes, depth: 19 mm1 x ASiASi profile cable1 Single Slave-
BWU3626depth: 19 mmIP67--1 x 2 channelsout of ASi-1 x M12 cable socket, straight, 5 poles-1 myes, depth: 19 mm1 x ASiASi profile cable1 Single Slave-

 

 

Analog Modules ASi: IP65/IP67, M12

Figure Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs analog Outputs analog

either as a single–wiring, Y–wiring or mixed-wiring.

M12 (5 poles)
Single-wiringY-wiringMixed-wiring


M8 (3 poles)
Single wiring

 

M8/M12 wiring

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

the connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Article No.
BWU31024 x M12IP672 x 0 ... 10 V-Signal at pin2/pin4out of ASi-2 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU31044 x M12IP672 x Pt100-Signal at pin1/pin3out of ASi-2 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU31054 x M12IP67-2 x 0 ... 20 mASignal at pin1/pin3-out of AUX2 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU31064 x M12IP67-2 x 0 ... 20 mASignal at pin2/pin4-out of AUX2 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU31074 x M12IP67-2 x 0 … 10 VSignal at pin1/pin3-out of AUX2 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU1893width: 45 mm IP652 x 4 … 20 mA-Signal at pin2/pin4out of ASi-2 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU1894width: 45 mm IP652 x 4 … 20 mA-Signal at pin2/pin4out of ASi-2 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU1963width: 45 mm IP652 x 0 ... 10 V-Signal at pin2/pin4out of ASi-2 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU1964width: 45 mm IP652 x 0 ... 10 V-Signal at pin2/pin4out of ASi-2 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU1895width: 45 mm IP652 x Pt100-Signal at pin2/pin4out of ASi-2 x M12 sockets, 5 polesASi profile cable1 AB Slave
BWU1917width: 90 mm IP651 x 4 … 20 mA/0 … 10 V1x 0 … 20 mASignal In at pin1/pin3, signal Out at pin2/pin4out of ASiout of ASi4 x M12 sockets, 5 polesASi profile cable2-4 Single Slaves
BWU1853width: 90 mm IP651 x 4 … 20 mA/0 … 10 V1x 0 … 10 VSignal In at pin1/pin3, signal Out at pin2/pin4out of AUXout of AUX4 x M12 sockets, 5 polesASi profile cable2-4 Single Slaves
BWU1359width: 90 mm IP654 x 4 … 20 mA-Signal at pin2/pin4out of ASi or out of AUX, auto switching-4 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU1360width: 90 mm IP654 x 0 ... 10 V-Signal at pin2/pin4out of ASi or out of AUX, auto switching-4 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU1363width: 90 mm IP654 x Pt100, 2/4 wire mode -Signal at pin2/pin4out of ASi-4 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU2532width: 90 mm IP654 x Pt100, 2/3 wire mode-Signal at pin2/pin4out of ASi-4 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU1722width: 90 mm IP65-4 x 0 … 20 mASignal at pin1/pin3-out of AUX4 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU1361width: 90 mm IP65-4 x 0 … 20 mASignal at pin1/pin3-out of ASi or out of AUX, auto switching4 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU1362width: 90 mm IP65-4 x 0 ... 10 VSignal at pin1/pin3-out of ASi or out of AUX, auto switching4 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU2857width: 90 mm IP65-4 x 0 … 10 V; 24 V, 0 V via M12Signal at pin1/pin3-out of ASi or out of AUX, auto switching4 x M12 sockets, 5 polesASi profile cable1 Single Slave
BWU23138 x M12IP672 x Pt100-Signal at pin2/pin4out of AUXout of AUX8 x M12 sockets, 5 polesASi profile cable2 AB Slaves

 

Analog Modules ASi: IP65, PG

Figure Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs analog Outputs analog

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

the connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Article No.
BWU12333 x PGIP652 x 0 ... 10 V-selectable, out of ASi or out of AUX, Default out of ASi-3 x PG cable connectorsASi profile cable1 Single Slave
BWU22403 x PGIP65Load cell-out of ASi-3 x PG cable connectorsASi profile cable1 Single Slave
BWU12343 x PGIP65-2 x 0 ... 20 mA-selectable, out of ASi or out of AUX, default out of ASi3 x PG cable connectorsASi profile cable1 Single Slave
BWU12353 x PGIP65-2 x 0 … 10 V-selectable, out of ASi or out of AUX, default out of ASi3 x PG cable connectorsASi profile cable1 Single Slave
BWU12548 x PGIP654 x Pt100 -out of ASi-8 x PG cable connectorsASi profile cable1 Single Slave
BWU15098 x PGIP654 x Pt1000 -out of ASi-8 x PG cable connectorsASi profile cable1 Single Slave

 

Digital Modules ASi: IP20, 22,5 mm

  • Cost efficient solution in IP20, 22,5 mm
Figure Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

"Control cabinet":
Cost-optimized modules whereby the supply voltage for the sensors and actuators is connected via additional patch terminals. Optimal application in the main control cabinet.


"Decentralized control cabinet":
Ideal for use in decentralized control cabinets. 3-wire sensors or actuators can be connected directly to terminals in the module

without additional patch terminals or the module has an extremely flat design.

Primary application
Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

the connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Article No.
BWU32724 x COMBICONIP20decentralized control cabinet44 x electronicout of ASiout of ASiclampsclamps1 Single Slave
BWU37473 x COMBICONIP20decentralized control cabinet4-out of ASi-clampsclamps1 AB Slave
BWU35594 x COMBICONIP20control cabinet44 x electronicout of AUXout of AUXclampsclamps1 AB Slave
BWU37334 x COMBICONIP20control cabinet43 x electronicout of AUXout of AUXclampsclamps1 AB Slave
BWU27233 x COMBICONIP20control cabinet4-out of AUX-clampsclamps1 AB Slave
BWU19384 x COMBICONIP20control cabinet44 x electronicout of AUXout of AUXclampsclamps1 AB Slave
BWU27594 x COMBICONIP20control cabinet44 x electronicout of AUXout of AUXclampsclamps1 Single Slave
BWU27214 x COMBICONIP20control cabinet8-out of AUX-clampsclamps2 AB Slaves
BWU32664 x COMBICONIP20decentralized control cabinet4-out of AUX-clampsclamps1 AB Slave
BWU32654 x COMBICONIP20decentralized control cabinet4-out of ASi-clampsclamps1 AB Slave
BWU34356 x COMBICONIP20control cabinet44 x relayout of ASi-clampsclamps1 Single Slave
BWU36586 x COMBICONIP20control cabinet44 x relayout of ASi-clampsclamps1 Single Slave (S-7.0.F.E)
BWU35496 x COMBICONIP20control cabinet44 x relayout of ASi-clampsclamps1 AB Slave
BWU24906 x COMBICONIP20control cabinet88 x electronicout of AUXout of AUXclampsclamps2 AB Slaves
BWU28006 x COMBICONIP20control cabinet88 x electronicout of AUXout of AUXclampsclamps2 Single Slaves
BWU33596 x COMBICONIP20control cabinet8 (NPN)8 x electronic (NPN)out of AUXout of AUXclampsclamps2 AB Slaves
BWU33646 x COMBICONIP20control cabinet88 x electronicout of ASiout of AUXclampsclamps2 AB Slaves
BWU32686 x COMBICONIP20decentralized control cabinet44 x electronicout of AUXout of AUXclampsclamps1 AB Slave
BWU32676 x COMBICONIP20decentralized control cabinet44 x electronicout of ASiout of AUXclampsclamps1 AB Slave
BWU37546 x COMBICONIP20decentralized control cabinet44 x electronicout of ASiout of AUXclampsclamps1 Single Slave

 

Digital Modules ASi in Stainless Steel, IP20

  • Robust, Stainless Steel in IP20
Figure Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

the connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Article No.
BW1808depth: 45 mmIP2043 x relayout of ASi-clampsclamps1 AB Slave
BWU1907depth: 45 mmIP2044 x electronicout of AUXout of AUXclampsclamps1 AB Slave
BWU2565depth: 45 mmIP2044 x electronicout of AUXout of AUXclampsclamps1 Single Slave
BWU2077depth: 45 mmIP208-out of AUX-clampsclamps2 AB Slaves
BWU2078depth: 45 mmIP20-8 x electronic-out of AUXclampsclamps2 AB Slaves
BW2555depth: 90 mmIP2044 x relayout of ASi-clampsclamps1 Single Slave
BWU2556depth: 90 mmIP208-out of AUX-clampsclamps2 AB Slaves

 

Analog Modules ASi: IP20

Figure Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs analog Outputs analog

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

the connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).

ASi connection

AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), mixed use allowed.
For modules with two slaves the second slave is turned off as long as the first slave is addressed to address "0".
Upon request, slaves are available with specific ASi Slave profiles.

ASi address
Article No.
BWU13454 x COMBICONIP202 x 4 ... 20 mA/2 x 0 … 10 V-selectable, out of ASi or out of AUX, Default out of ASi-clampsclamps1 Single Slave
BWU14124 x COMBICONIP20-2 x 0 … 20 mA/2 x 0 …10 V-selectable, out of ASi or out of AUX, default out of ASiclampsclamps1 Single Slave
BWU17274 x COMBICONIP20-2 x 0 … 20 mA/2 x 0 …10 V-selectable, out of ASi or out of AUX, default out of AUXclampsclamps1 Single Slave
BWU22244 x COMBICONIP20-2 x +-10 V-out of AUXclampsclamps1 Single Slave
BWU13646 x COMBICONIP204 x 4 … 20 mA-out of ASi or out of AUX, auto switching-clampsclamps1 Single Slave
BWU13656 x COMBICONIP204 x 0 ... 10 V-out of ASi or out of AUX, auto switching-clampsclamps1 Single Slave
BWU13686 x COMBICONIP204 x Pt100 -out of ASi-clampsclamps1 Single Slave
BWU19336 x COMBICONIP204 x thermocouple type J -out of ASi-clampsclamps1 Single Slave
BWU22436 x COMBICONIP204 x thermocouple type K-out of ASi-clampsclamps1 Single Slave
BWU13666 x COMBICONIP20-4 x 0 … 20 mA-out of ASi or out of AUX, auto switchingclampsclamps1 Single Slave
BWU13676 x COMBICONIP20-4 x 0 ... 10 V-out of ASi or out of AUX, auto switchingclampsclamps1 Single Slave

 

Replacement, ASi version 2.0