![](/fileadmin/_processed_/0/b/csm_4977_with_cable_a314fe2643.jpg)
BWU4977 | ASi-5 Self-configuring I/O Module, IP54, M12, 16I/O
ASi-5 self-configuring I/O module in cable duct housing in IP54, with 8 x M12 cable sockets, straight, 5 poles, up to 16 digital inputs, up to 16 digital outputs, Y/mixed wiring, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, flat design, installation in cable duct possible…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
-
View this product in section Drive solutions
![](/fileadmin/_processed_/4/7/csm_4979_with_cable_579fab8d84.jpg)
BWU4979 | ASi-5 Self-configuring I/O Module, IP54, M12, 8I/O
ASi-5 self-configuring I/O module in cable duct housing in IP54, with 4 x M12 cable sockets, straight, 5 poles, up to 8 digital inputs, up to 8 digital outputs, Y/mixed wiring, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, flat design, installation in cable duct possible…
![](/fileadmin/_processed_/b/7/csm_4740_with_cable_9345dfd246.jpg)
BWU4740 | Active Distributor ASi Motor Module for Lenze Smart Motor, IP67, 4I/3O
Active Distributor ASi Motor Module, IP67, housing depth 35 mm, for 1 x Lenze Smart Motor, 4 digital inputs, 3 digital outputs, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 0,3 m, 1 x M12 cable…
![](/fileadmin/_processed_/2/0/csm_3604_with_cable_f06ee01514.jpg)
BWU3604 | Active Distributor ASi Safety, IP54, 1SI/2O
Active Distributor ASi Safety, IP54, housing depth 35 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 2 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x round cable/connecting wires, cable length 2 m, flat…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/3/b/csm_4701_with_cable_329ce81774.jpg)
BWU4701 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 2 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/e/d/csm_3413_with_cable_21b390ed1d.jpg)
BWU3413 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x M12 cable socket, angled, 5 poles, cable length 1 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/7/2/csm_3553_with_cable_dd565db046.jpg)
BWU3553 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x M8cable socket, straight, 4 poles, cable length 0,20 m, flat design, installation in cable duct possible…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/8/c/csm_3373_with_cable_4d2011a41b.jpg)
BWU3373 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x round cable/connecting wires, cable length 0,3 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/0/1/csm_3600_with_cable_b54b48ec21.jpg)
BWU3600 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 2 x round cables/connecting wires, cable length 10 m, flat design, installation in cable duct possible (installation depth…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/a/2/csm_3626_with_cable_6e3e50626b.jpg)
BWU3626 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 1 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules