PROFIsafe Safety Protocol
PROFIsafe Products
ASi-5/ASi-3 Gateways PROFIsafe over PROFINET or PROFIsafe over PROFIBUS provide an interface for a PROFIBUS or PROFINET fieldbus. These ASi gateways are available in various versions with IP20 protection rating.
PROFIsafe, PROFINET ASi
Figure | Model |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| ASi-5/ASi-3 | Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Safety communication | Inputs Safety, SIL 3, Cat. 4 | Outputs Safety, SIL 3, cat. 4 | Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
PROFINET, OPC UA
|
ASi-5 + ASi-3 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
PROFIsafe (F-CPU) + Safe Link
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU3953 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated ASi-5/ASi-3 Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() |
Gateway with integrated Safety Monitor
|
PROFINET, OPC UA
|
ASi-5 + ASi-3 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
PROFIsafe (F-CPU) + Safe Link
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU3674 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() |
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
PROFINET, OPC UA
|
ASi-5 + ASi-3 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
PROFIsafe (F-CPU) + Safe Link
|
no local safe input
|
no local safe output
|
yes
|
yes
|
optional
| BWU3973 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated ASi-5/ASi-3 Safety Monitor, 2 ASi-5/ASi-3 master |
![]() |
Gateway with integrated Safety Monitor
|
PROFINET, OPC UA
|
ASi-5 + ASi-3 compatible
|
2 ASi networks, 2 ASi-5/ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
PROFIsafe (F-CPU) + Safe Link
|
no local safe input
|
no local safe output
|
yes
|
yes
|
optional
| BWU3833 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 master |
![]() |
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
PROFINET, OPC UA
|
ASi-5 + ASi-3 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
PROFIsafe (F-CPU) + Safe Link
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU3954 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated ASi-5/ASi-3 Safety Monitor, 1 ASi-5/ASi-3 master |
![]() |
Gateway with integrated Safety Monitor
|
PROFINET, OPC UA
|
ASi-5 + ASi-3 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
PROFIsafe (F-CPU) + Safe Link
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU3862 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
![]() |
Gateway with integrated ASi-5/ASi-3 Safety Monitor
|
PROFINET, OPC UA
|
ASi-5 + ASi-3 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
PROFIsafe (F-CPU) + Safe Link
|
no local safe input
|
no local safe output
|
yes
|
yes
|
optional
| BWU3974 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated ASi-5/ASi-3 Safety Monitor, 1 ASi-5/ASi-3 master |
![]() |
Gateway with integrated Safety Monitor
|
PROFINET, OPC UA
|
ASi-5 + ASi-3 compatible
|
1 ASi network, 1 ASi-5/ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
PROFIsafe (F-CPU) + Safe Link
|
no local safe input
|
no local safe output
|
yes
|
yes
|
optional
| BWU4018 ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
![]() |
Gateway with integrated Safety Monitor
|
PROFINET
|
ASi-3 compatible
|
2 ASi networks, 2 ASi-3 Masters
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
PROFIsafe (F-CPU) + Safe Link
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU3367 ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi masters |
![]() |
Gateway with integrated Safety Monitor
|
PROFINET
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet fieldbus + Ethernet diagnostic
|
PROFIsafe (F-CPU)
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU2794 ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 1 ASi master |
PROFIsafe, PROFIBUS ASi
Figure | Model |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| ASi-5/ASi-3 | Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Safety communication | Inputs Safety, SIL 3, Cat. 4 | Outputs Safety, SIL 3, cat. 4 | Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Gateway with integrated Safety Monitor
|
PROFIBUS
|
ASi-3 compatible
|
1 ASi network, 1 ASi-3 Master
|
yes, max. 4 A/ASi network
|
Ethernet diagnostic
|
PROFIsafe (F-CPU)
|
3 x 2 channels
|
6 release circuits, 6 x electronic safe outputs
|
yes
|
yes
|
optional
| BWU2819 ASi-3 PROFIsafe via PROFIBUS Gateway with integrated Safety Monitor, 1 ASi-3 master |