BWU4956Active Distributor ASi Safety, IP67, 1SI/2O

Product description

Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 2 digital outputs, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 8 poles + 1 x M12 cable socket, straight, 5 poles, cable length 10 m, flat design, installation in cable duct possible (installation depth >19 mm), connections for 1 x ASi and 1 x AUX profile cables, ASi connection via profile cable and piercing technology, 1 single address

Technical data

Inputs Safety, SIL 3, Cat. 4 1 x 2 channels
Outputs digital 2 x electronic
Safety signal inputs OSSDs
Input voltage (sensor supply)

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

out of AUX
Output voltage (actuator supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

out of AUX
Connection

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

1 x M12 cable socket, straight 8 poles + 1 x M12 cable socket, straight, 5 poles
Round cable

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

10 m
Flat design, installation in cable duct possible

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

yes, depth: 19 mm
Profile cable connection 1 x ASi, 1 x AUX 24 V
Special function to connect Leuze MLC530SPG (operation mode 4) to ASi

How to troubleshoot an existing ASi installation