Logo Bihl+Wiedemann GmbH

Gateways

Additional attributes:

Figure
Type
Model
Protection rating
Fieldbus interface
Number of AS-i networks, number of AS-i Master
1 power supply, 1 gateway for 2 AS-i networks, inexpensive power supplies
Diagnostic and configuration interface
Recognition of duplicate AS-i addresses
AS-i fault detector
Programming in C
Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4
Inputs safety, expandable to
Outputs Safety, SIL 3, cat. 4
Safety outputs, independent according to SIL 3, expandable to
Safety communication
Article No.
24 Volt AS-i Gateway
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
-
yes
yes
no
-
-
-
-
-
-
24 Volt AS-i Gateway
Gateway
IP20
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus
yes
yes
optional
-
-
-
-
-
-
24 Volt AS-i Gateway
Gateway
IP20
EtherNet/IP + Modbus/TCP
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus
yes
yes
no
-
-
-
-
-
-
24 Volt AS-i Gateway
Gateway
IP20
EtherCAT
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus
yes
yes
no
-
-
-
-
-
-
24 Volt AS-i Gateway
Gateway
IP20
POWERLINK
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
-
yes
yes
no
-
-
-
-
-
-
24 Volt AS-i Gateway
Gateway
IP20
CC-Link
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
-
yes
yes
no
-
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network
-
no
yes
no
-
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
-
PROFIBUS AS-i
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
-
no
yes
no
-
-
-
-
-
-
Starter Kits
Gateway
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
-
PROFIBUS AS-i Basic
Gateway
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
-
no
yes
no
-
-
-
-
-
-
PROFINET AS-i
Gateway
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus
yes
yes
optional
-
-
-
-
-
-
PROFINET AS-i
Gateway
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
Ethernet fieldbus
yes
yes
optional
-
-
-
-
-
-
PROFINET AS-i
Gateway
IP20
PROFINET
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
Ethernet fieldbus
yes
yes
optional
-
-
-
-
-
-
PROFINET AS-i
Gateway
IP20
PROFINET
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
-
EtherNet/IP + ModbusTCP AS-i
Gateway
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
-
-
-
-
-
-
EtherNet/IP + ModbusTCP AS-i
Gateway
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
Ethernet fieldbus + RS 232
yes
yes
optional
-
-
-
-
-
-
EtherNet/IP + ModbusTCP AS-i
Gateway
IP20
EtherNet/IP + Modbus/TCP
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
-
-
-
-
-
-
BACnet/IP AS-i
Gateway
IP20
BACnet/IP
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
-
-
-
-
-
-
DeviceNet AS-i
Gateway
IP20
DeviceNet
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
-
DeviceNet AS-i
Gateway
IP20
DeviceNet
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
RS 232
yes
yes
no
-
-
-
-
-
-
DeviceNet AS-i
Gateway
IP20
DeviceNet
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
-
ControlLogix AS-i
Gateway
IP20
ControlLogix
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network
RS 232
no
no
no
-
-
-
-
-
-
ControlLogix AS-i
Gateway
IP20
complete set ControlLogix
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network
RS 232
no
no
no
-
-
-
-
-
-
Compact- / MicroLogix AS-i
Gateway
IP20
CompactLogix, MicroLogix1500
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
RS 232
no
no
no
-
-
-
-
-
-
Compact- / MicroLogix AS-i
Gateway
IP20
complete set CompactLogix, MicroLogix1500
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
RS 232
no
no
no
-
-
-
-
-
-
EtherCAT AS-i
Gateway
IP20
EtherCAT
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
no
-
-
-
-
-
-
EtherCAT AS-i
Gateway
IP20
EtherCAT
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
RS 232
yes
yes
no
-
-
-
-
-
-
EtherCAT AS-i
Gateway
IP20
EtherCAT
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
-
CC-Link AS-i
Gateway
IP20
CC-Link
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
-
no
yes
no
-
-
-
-
-
-
CANopen AS-i
Gateway
IP20
CANopen
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
-
CANopen AS-i
Gateway
IP20
CANopen
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
RS 232
yes
yes
no
-
-
-
-
-
-
CANopen AS-i
Gateway
IP20
CANopen
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
-
RS 485 Modbus AS-i
Gateway
IP20
Modbus/RTU; RS 485
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
-
RS 485 Modbus AS-i
Gateway
IP20
Modbus/RTU; RS 485
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
RS 232
yes
yes
no
-
-
-
-
-
-
RS 485 Modbus AS-i
Gateway
IP20
Modbus/RTU; RS 485
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
RS 232
yes
yes
no
-
-
-
-
-
-
RS 232 AS-i
Gateway
IP20
RS 232
1 AS-i network, 1 AS-i Master
no, max. 8 A/AS-i network
-
no
yes
no
-
-
-
-
-
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
4
-
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
no
4
-
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
no
4
-
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
no
4
-
max. 62 x 2 channels
2 release circuits; 2 x 2 relay
max. 16
-
Safety, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
Starter Kits
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
4
-
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
4
-
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
Starter Kits
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Starter Kits
Gateway with integrated Safety Monitor
IP20
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels
6 release circuits; 6 x fast electronic safe outputs
max. 31
PROFIsafe (F-CPU) + ASIMON program
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
4
-
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON program
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
2 AS-i networks, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
4
-
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON program
PROFIsafe, PROFIBUS
Gateway with integrated Safety Monitor
IP20
PROFIBUS
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
RS 232
yes
yes
no
-
-
max. 31 x 2 channels
-
max. 16
PROFIsafe (F-CPU)
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 64, max. 1984 in max. configuration
PROFIsafe (F-CPU) + ASIMON program + Safe Link
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
-
-
max. 62 x 2 channels
-
max. 16
PROFIsafe (F-CPU) + ASIMON program
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + RS 232
yes
yes
optional
4
-
max. 62 x 2 channels
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 16
PROFIsafe (F-CPU) + ASIMON program
PROFIsafe, PROFINET
Gateway with integrated Safety Monitor
IP20
PROFINET
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels
6 release circuits; 6 x fast electronic safe outputs
max. 31
PROFIsafe (F-CPU) + ASIMON program
Safety, Sercos
Gateway with integrated Safety Monitor
IP20
Sercos
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 64, max. 1984 in max. configuration
CIP Safety over Sercos + Safe Link
Safety, Sercos
Gateway with integrated Safety Monitor
IP20
Sercos
2 AS-i networks, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 64, max. 1984 in max. configuration
safe Schneider drives over Sercos + Safe Link
Safety, Sercos
Gateway with integrated Safety Monitor
IP20
Sercos
2 AS-i networks, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
4
-
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels
6 release circuits; 6 x fast electronic safe outputs
max. 64
CIP Safety over EtherNet/IP
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
4
-
max. 62 x 2 channels, max. 1922 in max. configuration
4 release circuits; 2 x relay, 2 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
EtherNet/IP + Modbus/TCP
2 AS-i networks, 2 AS-i Masters
no, max. 8 A/AS-i network, redundant supply
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, EtherNet/IP + ModbusTCP
Gateway with integrated Safety Monitor
IP20
EtherNet/IP + Modbus/TCP
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet fieldbus + Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
Safety, DeviceNet
Gateway with integrated Safety Monitor
IP20
DeviceNet
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
EtherCAT
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 64, max. 1984 in max. configuration
FSoE + Safe Link
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
EtherCAT
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
EtherCAT
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
FSoE + Safe Link
Safety, EtherCAT
Gateway with integrated Safety Monitor
IP20
EtherCAT
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
Safety, POWERLINK
Gateway with integrated Safety Monitor
IP20
POWERLINK
2 AS-i networks, 2 AS-i Masters
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 62 x 2 channels, max. 1922 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 32, max. 992 in max. configuration
Safe Link
Safety, POWERLINK
Gateway with integrated Safety Monitor
IP20
POWERLINK
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
Safety, CANopen
Gateway with integrated Safety Monitor
IP20
CANopen
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link
Safety, CC-Link
Gateway with integrated Safety Monitor
IP20
CC-Link
1 AS-i network, 1 AS-i Master
yes, max. 4 A/AS-i network
Ethernet diagnostic
yes
yes
optional
6
3 x 2 channels
max. 31 x 2 channels, max. 1891 in max. configuration
6 release circuits; 6 x fast electronic safe outputs
max. 31, max. 991 in max. configuration
Safe Link