BW3452Passive Cable Duct Motor Module, IP54, M8 for Itoh Denki, 2I

  • For automated conveying with zero pressure accumulation in conjunction with special sensors, such as Wenglor OPT244


Our specialists are happy to support you on an hourly basis with product configuration.


There is a successor to this article → BW4921

  • Logo_CE

Product description

Passive Cable Duct Motor Module in IP54, with 5 x M8 cable sockets for 2 x 24 V motorized rollers Itoh Denki (PM500XE/XP, PM605XE/XP), 2 digital inputs (light barrier), 2 digital outputs, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, internal line protection, separately for each motor 3,5 A (slow-blow fuse), flat design, installation in cable duct possible (installation depth > 19 mm), periphery connection via 2 x M8 cable sockets, straight, 5 poles, 1 x M8 cable plug, straight, 5 poles and 2 x M8 cable sockets, straight, 4 poles, cable length of motor connections 0,43 m, cable length of input connections 0,09 m, cable length of AUX connection 0,13 m

Technical data

Type passive cable duct motor module
Housing depth: 18 mm
Protection rating

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

IP54
Drive

If you cannot find your drive, please do not hesitate to contact us. Bihl+Wiedemann creates customized drive solutions with ASi for motorized rollers, DC motors and frequency inverters.

Itoh Denki PM500XE/XP, Itoh Denki PM605XE/XP
Number of Drives 2
Line protection fuse

"yes":

In the motor module UL approved fuses are placed before each of the motor supply connections. A short circuit in the motor causes this fuse to blow, protecting the connection cable between the module and motor.

After blowing the not exchangeable fuse the module is no longer functional and the module needs to be replaced. The characteristics of the fuse must be checked against the motor data before using the module.

The protection circuit in the module allows a very simple protection of the motor cables. The fuse for the cable protection is a slow-blow one; without short circuit the robust behavior of the module remains.


"no":

The motor module is designed to supply the 24 V directly to the motor. At high currents or surges as they occur for example at braking, the module will not be damaged.

The cable protection should be realized outside the motor module with additional measures.

yes, separately for each motor, 3,5 A (slow-blow fuse)
Flat design, installation in cable duct possible

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

yes, depth: 18 mm
Inputs digital 2 x light barrier
Outputs digital no digital outputs
Input voltage (sensor supply)

inputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

out of AUX
Output voltage (actuator supply)

Electronic outputs are supplied by ASi or by AUX (24 V or 48 V auxiliary power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

out of AUX
Connection 2 x M8 cable sockets, straight, 5 poles+ 1 x M8 cable plug, straight, 5 poles + 2 x M8 cable sockets, straight, 4 poles
Round cable

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

M: 0,43 m, I: 0,09 m, AUX: 0,13 m

The product has earned the following certifications: