Active Distributors ASi Safety

Active distributors ASi Safety from Bihl+Wiedemann allow you to make any safety sensor, safety push-button or switch AS-Interface capable. Even modules without their own ASi terminal can be easily integrated into an existing ASi network using these active distributors ASi Safety. Other features include individually configurable connection options using M8 or M12 connectors, connecting wires or push-in terminals to conform to the customer’s application, as well as a compact form factor, making them ideal for use in cable ducts.

Active distributors ASi Safety from Bihl+Wiedemann allow you to make any safety sensor, safety push-button or switch AS-Interface capable. Even modules without their own ASi terminal can be easily integrated into an existing ASi network using these active distributors ASi Safety. Other features include individually configurable connection options using M8 or M12 connectors, connecting wires or push-in terminals to conform to the customer’s application, as well as a compact form factor, making them ideal for use in cable ducts.
Figure |
Inputs Safety, SIL 3, Cat. 4
|
Safety signal inputs
|
Outputs digital
|
Input voltage (sensor supply)
|
Output voltage (actuator supply)
|
Connection
|
Round cable
|
Flat design, installation in cable duct possible
|
Profile cable connection
|
Special function
|
---|---|---|---|---|---|---|---|---|---|---|
1 x 2 channels
|
floating contacts
|
2 x electronic
|
out of ASi
|
out of ASi
|
1 x round cable/connecting wires + 1 x ASi addressing cable socket
|
2 m
|
yes, depth: 35 mm
|
1 x ASi
|
to connect 2 x NC contacts to ASi
| |
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of AUX
|
1 x round cable/connecting wires
|
1 m
|
yes, depth: 35 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect 2 x NC contacts to ASi
| |
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
yes, depth: 35 mm
|
1 x ASi, 1 x AUX 24 V
|
-
| |
1 x 2 channels
|
OSSDs
|
2 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight 8 poles + 1 x M12 cable socket, straight, 5 poles
|
10 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect Leuze MLC530SPG (operation mode 4) to ASi
| |
1 x 2 channels
|
OSSDs
|
2 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight 8 poles + 1 x M12 cable socket, straight, 5 poles
|
10 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect Leuze MLC530SPG (operation mode 5) to ASi
| |
1 x 2 channels
|
OSSDs
|
2 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight 8 poles + 1 x M12 cable socket, straight, 5 poles
|
SI/O: 0,5 m, 24V: 2 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
To connect Sick deTec4 to ASi
| |
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
2 x round cables/connecting wires
|
1 m
|
yes, depth: 19 mm
|
1 x ASi
|
to connect 2 x NC contacts to ASi
| |
1 x 2 channels
|
floating contacts
|
-
|
out of ASi
|
-
|
2 x round cables/connecting wires
|
10 m
|
yes, depth: 19 mm
|
1 x ASi
|
to connect 2 x NC contacts to ASi
| |
1 x 2 channels
|
OSSDs
|
2 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
2 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect Leuze MLD530-RT3M (operation mode 5) to ASi
| |
1 x 2 channels
|
OSSDs
|
2 x electronic
|
out of AUX
|
out of AUX
|
1 x round cable/connecting wires
|
2 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect Leuze MLD530-RT3M to ASi
| |
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
1 x round cable/connecting wires
|
10 m
|
yes, depth: 19 mm
|
1 x ASi
|
to connect 2 x NC contacts to ASi
| |
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
1 x round cable/connecting wires
|
1 m
|
yes, depth: 19 mm
|
1 x ASi
|
to connect 2 x NC contacts to ASi
| |
1 x 2 channels
|
floating contacts
|
-
|
out of ASi
|
-
|
1 x round cable/connecting wires
|
0,30 m
|
yes, depth: 19 mm
|
1 x ASi
|
to connect 2 x NC contacts to ASi
| |
1 x 2 channels
|
floating contacts
|
-
|
out of ASi
|
-
|
1 x M8 cable socket, straight, 4 poles
|
0,20 m
|
yes, depth: 19 mm
|
1 x ASi
|
to connect Sick RE13-SA84 / RE13-SAC / RE23-SAC / RE23-SA84 to ASi
| |
1 x 2 channels
|
floating contacts
|
-
|
out of ASi
|
-
|
1 x M12 cable socket, angled, 5 poles
|
1 m
|
yes, depth: 19 mm
|
1 x ASi
|
to connect E-STOP buttons to ASi via M12
| |
1 x 2 channels
|
floating contacts
|
-
|
out of ASi
|
-
|
1 x M12 cable socket, straight, 5 poles
|
1 m
|
yes, depth: 19 mm
|
1 x ASi
|
to connect E-STOP buttons to ASi via M12
| |
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
1 x M12 cable socket, angled, 8 poles
|
1 m
|
yes, depth: 19 mm
|
1 x ASi
|
-
| |
1 x 2 channels
|
floating contacts
|
-
|
out of ASi
|
-
|
1 x M12 cable socket, straight, 5 poles
|
2 m
|
yes, depth: 19 mm
|
1 x ASi
|
to connect E-STOP buttons to ASi via M12
| |
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, angled, 5 poles
|
1 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
-
| |
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 5 poles
|
5 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
-
| |
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 5 poles
|
1 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect Euchner MGB / Pizzato ST GD110MP-G1T to ASi
| |
1 x 2 channels
|
OSSDs
|
-
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 5 poles
|
5 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect door contact switch Keyence GS-10PC Series
| |
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
5 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect Pilz PSENslock, PSENcode to ASi
| |
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect Pilz PSENslock, PSENcode to ASi
| |
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect Schmersal AZM400 to ASi
| |
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
yes, depth: 19 mm
|
1 x ASi, 1 x AUX 24 V
|
to connect Schmersal AZM200 / AZM201 / AZM300 / MZM100 / RSS 16 to ASi
| |
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
yes, depth: 19 mm
|
1 x ASi
|
-
|