Active Distributors ASi Safety
Active distributors ASi Safety from Bihl+Wiedemann allow you to make any safety sensor, safety push-button or switch AS-Interface capable. Even modules without their own ASi terminal can be easily integrated into an existing ASi network using these active distributors ASi Safety. Other features include individually configurable connection options using M8 or M12 connectors, connecting wires or push-in terminals to conform to the customer’s application, as well as a compact form factor, making them ideal for use in cable ducts.
If you cannot find the safety application you are looking for, please do not hesitate to contact us. Bihl+Wiedemann creates customized safety solutions with ASi for your application.
Active distributors ASi Safety from Bihl+Wiedemann allow you to make any safety sensor, safety push-button or switch AS-Interface capable. Even modules without their own ASi terminal can be easily integrated into an existing ASi network using these active distributors ASi Safety. Other features include individually configurable connection options using M8 or M12 connectors, connecting wires or push-in terminals to conform to the customer’s application, as well as a compact form factor, making them ideal for use in cable ducts.
If you cannot find the safety application you are looking for, please do not hesitate to contact us. Bihl+Wiedemann creates customized safety solutions with ASi for your application.
Figure |
Inputs Safety
|
Safety signal inputs
|
Outputs digital
|
Input voltage (sensor supply)
|
Output voltage (actuator supply)
|
Connection
|
Round cable
|
Special function
| |
---|---|---|---|---|---|---|---|---|---|
1 x 2 channels
|
floating contacts
|
2 x electronic
|
out of ASi
|
out of ASi
|
1 x ASi addressing cable socket, 1 x round cable/connecting wires
|
2 m
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
1 x M12 cable socket, angled, 8 poles
|
2 m
|
-
| ||
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
1 x M12 cable socket, angled, 8 poles
|
1 m
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
2 x round cables/connecting wires
|
1 m
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
1 x round cable/connecting wires
|
10 m
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of ASi
|
1 x round cable/connecting wires
|
1 m
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
1 x electronic
|
out of ASi
|
out of AUX
|
1 x round cable/connecting wires
|
1 m
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
no digital outputs
|
out of ASi
|
no output voltage
|
1 x M12 cable socket, straight, 5 poles
|
2 m
|
to connect E-STOP buttons to ASi via M12
| ||
1 x 2 channels
|
floating contacts
|
no digital outputs
|
out of ASi
|
no output voltage
|
1 x M12 cable socket, straight, 5 poles
|
1 m
|
to connect E-STOP buttons to ASi via M12
| ||
1 x 2 channels
|
floating contacts
|
no digital outputs
|
out of ASi
|
no output voltage
|
1 x M12 cable socket, angled, 5 poles
|
1 m
|
to connect E-STOP buttons to ASi via M12
| ||
1 x 2 channels
|
floating contacts
|
no digital outputs
|
out of ASi
|
no output voltage
|
1 x M8 cable socket, straight, 4 poles
|
0,20 m
|
to connect Sick RE13-SA84 / RE13-SAC / RE23-SAC / RE23-SA84 to ASi
| ||
1 x 2 channels
|
floating contacts
|
no digital outputs
|
out of ASi
|
no output voltage
|
2 x round cables/connecting wires
|
10 m
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
no digital outputs
|
out of ASi
|
no output voltage
|
1 x round cable/connecting wires
|
0,30 m
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
OSSDs
|
2 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 5 poles, 1 x M12 cable socket, straight, 8 poles
|
10 m
|
to connect Leuze MLC530SPG (operation mode 5) to ASi
| ||
1 x 2 channels
|
OSSDs
|
2 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 5 poles, 1 x M12 cable socket, straight, 8 poles
|
10 m
|
to connect Leuze MLC530SPG (operation mode 4) to ASi
| ||
1 x 2 channels
|
OSSDs
|
2 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 5 poles, 1 x M12 cable socket, straight, 8 poles
|
SI/O: 0,5 m, 24V: 2 m
|
To connect Sick deTec4 to ASi
| ||
1 x 2 channels
|
OSSDs
|
2 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
2 m
|
to connect Leuze MLD530-RT3M (operation mode 5) to ASi
| ||
1 x 2 channels
|
OSSDs
|
2 x electronic
|
out of AUX
|
out of AUX
|
1 x round cable/connecting wires
|
2 m
|
to connect Leuze MLD530-RT3M to ASi
| ||
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
5 m
|
to connect Pilz PSENslock, PSENcode to ASi
| ||
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
to connect Pilz PSENslock, PSENcode to ASi
| ||
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
to connect Schmersal AZM400 to ASi
| ||
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
to connect Schmersal AZM200 / AZM201 / AZM300 / MZM100 / RSS 16 to ASi
| ||
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 8 poles
|
1 m
|
to connect Keyence GS-71PC / GS-11PC / GS-M51P / GS-ML51P / GS-M91P to ASi
| ||
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 5 poles
|
5 m
|
no special function
| ||
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 5 poles
|
1 m
|
to connect Euchner MGB / Pizzato ST GD110MP-G1T to ASi
| ||
1 x 2 channels
|
OSSDs
|
1 x electronic
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, angled, 5 poles
|
1 m
|
no special function
| ||
1 x 2 channels
|
OSSDs
|
no digital outputs
|
out of AUX
|
out of AUX
|
1 x M12 cable socket, straight, 5 poles
|
5 m
|
to connect door contact switch Keyence GS-10PC Series
|