Building Automation

The benefits of AS-Interface – such as the simple, cost-saving installation and high degree of flexibility – have now established themselves in building automation. Numerous companies are already using the ASi installation system, for example for controlling fire and smoke dampers, shutter drives or heating and cooling ceilings using analog output modules. Damper drives with flow regulators can be connected to the controller through the MP-Bus gateway. It is also possible to process EnOcean signals from wireless pushbuttons and sensors over ASi. During your planning and application implementation phases we can be at your side and are open to application-specific special solutions.

 

ASi Gateways in Stainless Steel

  • BACnet/IP
  • PROFINET
  • PROFIBUS
  • Modbus RTU
  • EtherNet/IP + Modbus TCP
Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix fieldbus

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway: interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.

 

 

 

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU4778BACnet/IP ASiGateway IP20BACnet/IP, OPC UA2 ASi networks, 2 ASi-3 Mastersyes, max. 8 A/ASi networkEthernet fieldbus + Ethernet diagnosticyesyesoptional
BWU3356BACnet/IP ASiGateway IP20BACnet/IP, OPC UA2 ASi networks, 2 ASi-3 Mastersno, max. 8 A/ASi network, redundant supplyEthernet fieldbus + Ethernet diagnosticyesyesoptional
BWU1642RS 485 Modbus ASiGateway IP20Modbus/RTU; RS 4852 ASi networks, 2 ASi-3 Mastersno, max. 8 A/ASi network, redundant supplyRS 232yesyesno
BWU1641RS 485 Modbus ASiGateway IP20Modbus/RTU; RS 4851 ASi network, 1 ASi-3 Masterno, max. 8 A/ASi networkRS 232yesyesno
BWU2239PROFINET ASiGateway IP20PROFINET2 ASi networks, 2 ASi-3 Mastersno, max. 8 A/ASi network, redundant supplyEthernet fieldbus + RS 232yesyesoptional
BWU2545PROFIBUS ASiGateway IP20PROFIBUS2 ASi networks, 2 ASi-3 Mastersno, max. 8 A/ASi network, redundant supplyEthernet diagnosticyesyesoptional
BWU2544PROFIBUS ASiGateway IP20PROFIBUS1 ASi network, 1 ASi-3 Masterno, max. 8 A/ASi networkEthernet diagnosticyesyesoptional

 

 

ASi Gateways with integrated Safety Monitor

  • BACnet/IP
Figure Type Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix fieldbus

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway: interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.

 

 

 

 

The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU4780Safety, BACnet/IPGateway with integrated Safety MonitorIP20BACnet/IP, OPC UA2 ASi networks, 2 ASi-3 Mastersyes, max. 8 A/ASi networkEthernet fieldbus + Ethernet diagnostic-yesoptional63 x 2 channelsmax. 128 x 2 channels, max. 3968 in max. configuration6 release circuits, 6 x electronic safe outputsmax. 128, max. 3968 in max. configurationSafe Link
BWU4001Safety, BACnet/IPGateway with integrated Safety MonitorIP20BACnet/IP, OPC UA2 ASi networks, 2 ASi-3 Mastersno, max. 8 A/ASi network, redundant supplyEthernet fieldbus + Ethernet diagnosticyesyesoptional63 x 2 channelsmax. 128 x 2 channels, max. 3968 in max. configuration6 release circuits, 6 x electronic safe outputsmax. 128, max. 3968 in max. configurationSafe Link

 

 

Power Supplies

Figure

"ASi power supply":

Special power supplies with integrated data decoupling unit for use in ASi-3 only networks. Suitable for all Bihl+Wiedemann ASi-3 gateways and safety monitors.

"30 V power supply":

Inexpensive standard power supplies, suitable as an alternative for use with ASi gateways and safety monitors with integrated data decoupling unit (version "1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi gateways.


30 V power supply, optimized for ASi-5/ASi-3:

Inexpensive standard power supplies, optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated data decoupling unit (version "1 power supply , 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.


30 V power supply, optimized for ASi-5/ASi-3, NEC class 2 :

The 30 V/3 A power supply is UL certified, has power limitation <100 W and is designed for use in NEC class 2 networks. It is suitable for applications with 1 power supply per ASi network. In the case of power intensive applications, Bihl+Wiedemann recommends the use of a 30 V power supply without 100 W power limitation in combination with a power limitation module (BWU4189) for each ASi network.The power supply is optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated decoupling coils (version "1 power supplies, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 V ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.


"ASi power supply decoupling unit":

Supply of 2 ASi networks out of 1 power supply. Applicable with double masters without integrated data decoupling.


"Power decoupling unit":

Take up to 1,2 A out of ASi. In combination with an ASi Repeater: decouples 1,2 A from ASi Segment B and supplies Segment A with 1,2 A.

Power supply
Input voltage Output current

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Article No.
BW422130 V power supply, optimized for ASi-5/ASi-3100 ... 240 VAC, 1 phase16 AIP20
BW421930 V power supply, optimized for ASi-5/ASi-3100 ... 240 VAC, 1 phase8 AIP20
BW421830 V power supply, optimized for ASi-5/ASi-3100 ... 240 VAC, 1 phase4 AIP20
BW1997ASi power supply115 VAC / 230 VAC, power supply with range switch8 AIP20
BW1649ASi power supply90 ... 265 VAC, wide range supply4 AIP20
BW2255ASi power supply115 ... 250 VAC1,8 AIP20

 

Fire damper "Stand alone" control unit

  • provided as a kit in rugged plastic housing, pre-wired for easy and fast installation
  • pre-installed user software,no further configuration needed
  • centralized control of damper drives and detection of damper positions
  • plain text display and spontaneous diagnostics directly via device display and function LEDs
  • automated testing of damper function via different test modes
Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Number of fire dampers Number of fire damper groups Number of building ventilation system releases Controlling ventilation, fire, smoke dampers Article No.
BW3545Fire damper "Stand alone" control unitBACnet, 2 ASi networks, max. 120 / 240 fire damperspolystyrol, 450/300/209IP65120 / 24062, extensible-
BW3547Fire damper "Stand alone" control unitPROFINET, 1 ASi network, max. 30 / 60 fire damperspolystyrol, 300/300/209IP6530 / 6031, extensible-
BW3550Control program for fire damper "Stand alone" control unitsoftware--60 / 12062, extensible-

Fire/smoke dampers

  • Controlling ventilation, fire, smoke dampers
  • Requirements for Germany and EC
  • Requirements for Switzerland (IG-BSK)
  • 24V/230V relay
  • EN 6206 SIL2
Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BW2482ventilation damper moduleventilation, fire, smoke dampers-IP5442 x electronicout of ASiout of ASi1 Single address
BW2028ventilation damper moduleventilation, fire, smoke dampers-IP5442 x electronicout of ASiout of ASi1 Single address
BW2029ventilation damper moduleventilation, fire, smoke dampers-IP5432 x electronicout of AUXout of AUX1 AB address
BW2080ventilation damper moduleventilation, fire, smoke dampers (Switzerland)-IP5432 x electronicout of ASiout of ASi1 AB address
BW3005ventilation damper module, Safetyventilation, fire, smoke dampers-IP4042 x electronicout of ASiout of ASi1 Single address
BW4917ventilation damper module, Safetyventilation, fire, smoke dampers-IP4042 x electronicout of ASiout of ASi1 Single address
BW3009ventilation damper moduleventilation, fire, smoke dampers (230 V relay)-IP5444 x relayout of ASi-1 AB address
BW3010ventilation damper moduleventilation, fire, smoke dampers (230 V relay)-IP544 + 2 x fusible link2 x relayout of ASi-1 AB address
BW3011ventilation damper moduleventilation, fire, smoke dampers (230 V relay)-IP5442 x relayout of ASi-1 AB address
BW2480ventilation damper moduleventilation, fire, smoke damperssurface-mounted boxIP544-out of ASi-1 AB address
BW3412I/O for manual call pointsI/O modulessurface-mounted boxIP5444 x electronicout of AUXout of AUX1 AB address

 

Heating, Ventilating and Air Conditioning & Building Automation in General

  • Shutter modules
  • Heating/air conditioning
  • EnOcean
  • MP Bus
Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital Inputs analog Outputs analog

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)
Controlling heating/air conditioning Article No.
BW2114shutter modulecontrolling 230 V shutters-IP5484 x relay--out of ASi--
BW3944shutter modulecontrolling 230 V shutters-IP4084 x relay--out of ASi--
BW2701I/O for VAV boxesI/O modulessurface-mounted boxIP54--1 x 0 ... 10 V1x 0 … 10 Vselectable, out of ASi or out of AUX, Default out of ASiselectable, out of ASi or out of AUX, default out of ASi-
BW2536heating/air conditioning (24 V AC/DC)heating/air conditioning, 0 … 10 V, (climate control ceilings)surface-mounted boxIP54-2 x electronic-2 x 0 … 10 Vout of ASiselectable, out of ASi or out of AUX (AC/DC), default out of ASiControlling heating and climate control ceilings
BW2537heating/air conditioning (24 V AC/DC)analog inputs 0 ... 10 V (temperature CO2 etc.) + digital inputssurface-mounted boxIP542-2 x 0 ... 10 V-selectable, out of ASi or out of AUX (AC/DC), default out of ASi-Recording of analog values
BW2138Heating/air conditioningheating/air conditioning (valves)surface-mounted boxIP54-4 x electronic---out of AUXControlling valves and heating valves
BW2128PCB building automation I/O modulesOEM boardIP0043 x electronic--out of AUXout of AUX-
BW2375connection to EnOcean connection to EnOceanwhiteIP4031 x 4EnOcean8 x 6EnOceanout of ASi--
BW2473connection to EnOcean connection to EnOceanblackIP4031 x 4EnOcean8 x 6EnOceanout of ASi--
BW2580connection to EnOcean, surface-mounted boxconnection to EnOceansurface-mounted boxIP4031 x 4EnOcean8 x 6EnOceanout of ASi--
BW2406connection to MP-Busconnection to MP-Bus-IP54----out of ASiout of AUX-
BWU1232IP65, 3 x PGI/O modules3 x PGIP65--2 x 4 … 20 mA-selectable, out of ASi or out of AUX, Default out of ASi--
BWU1233IP65, 3 x PGI/O modules3 x PGIP65--2 x 0 ... 10 V-selectable, out of ASi or out of AUX, Default out of ASi--
BWU1234IP65, 3 x PGI/O modules3 x PGIP65---2 x 0 ... 20 mA-selectable, out of ASi or out of AUX, default out of ASi-
BWU1235IP65, 3 x PGI/O modules3 x PGIP65---2 x 0 … 10 V-selectable, out of ASi or out of AUX, default out of ASi-
BWU1254IP65, 8 x PGI/O modules8 x PGIP65--4 x Pt100 -out of ASi--
BWU1509IP65, 8 x PGI/O modules8 x PGIP65--4 x Pt1000 -out of ASi--
BWU1933IP20, 25 mm x 105 mm, 6 x 4 contactsI/O modules25.0 mm x 105.0 mm x 114.5 mm, 6 x 4 contactsIP20--4 x thermocouple type J -out of ASi--
BWU2243IP20, 25 mm x 105 mm, 6 x 4 contactsI/O modules25.0 mm x 105.0 mm x 114.5 mm, 6 x 4 contactsIP20--4 x thermocouple type K-out of ASi--
BW3779PCB, flush-mounted module, coatedI/O modulescoatedIP00, thick coated44 x electronic--out of ASiout of ASi-
BW2388PCB, flush-mounted module, coatedI/O modulescoatedIP00, thick coated4---out of ASi--

 

Active Distributors ASi, IP67/IP20

Figure Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible

status of in- and outputs is indicated by LEDs. In addition to that, both ASi LEDs (PWR green and FAULT red) show - as usual regarding the ASi modules - the status of the ASi modules. Uaux is indicated by a green LED.

LED status display

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

Round cable

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BWU331744 x electronicout of ASiout of AUXyes, depth: 35 mmyes2 x round cables/connecting wires1 m1 AB address
BWU332644 x electronicout of ASiout of ASiyes, depth: 35 mmyes2 x round cables/connecting wires1 m1 AB address
BW3300-4 x electronic-out of AUXyes, depth: 19 mmyes1 x round cable/connecting wires1 m1 AB address
BWU33494-out of AUX-yes, depth: 19 mmyes8 x push in terminalsno1 AB address
BWU341431 x electronicout of AUXout of AUXyes, depth: 19 mmyes8 x push in terminalsno1 AB address
BWU3342-4 x electronic-out of AUXyes, depth: 19 mmyes8 x push in terminalsno1 AB address

 

 

I/O Modules for installation in control cabinets/decentralized control cabinets, IP20

  • Robust, Stainless Steel in IP20
  • Cost efficient solution in IP20, 22,5 mm
Figure Model Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BW1926I/O modules44 x relayout of ASi-1 Single address
BW1808I/O modules43 x relayout of ASi-1 AB address
BW1907I/O modules44 x electronicout of AUXout of AUX1 AB address
BWU2565I/O modules44 x electronicout of AUXout of AUX1 Single address
BWU2077I/O modules8-out of AUX-2 AB addresses
BW2555I/O modules44 x relayout of ASi-1 Single address
BW2556I/O modules8-out of AUX-2 AB addresses
BWU3874I/O modules16-out of AUX-1 ASi-5 address
BWU3873I/O modules8-out of AUX-1 ASi-5 address
BWU3872I/O modules88 x electronicout of AUXout of AUX1 ASi-5 address
BWU3842I/O modules44 x electronicout of AUXout of AUX, 2 A per output1 AB address
BWU3559I/O modules44 x electronicout of AUXout of AUX1 AB address
BWU2723I/O modules4-out of AUX-1 AB address
BWU1938I/O modules44 x electronicout of AUXout of AUX1 AB address
BWU2759I/O modules44 x electronicout of AUXout of AUX1 Single address
BWU2721I/O modules8-out of AUX-2 AB addresses
BWU3549I/O modules44 x relayout of ASi-1 AB address
BWU2490I/O modules88 x electronicout of AUXout of AUX2 AB addresses
BWU2800I/O modules88 x electronicout of AUXout of AUX2 Single addresses

 

 

I/O Modules for installation on ceiling, walls and floor, IP54

Figure Type Model Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BW2139I/O in surface-mounted boxI/O modulessurface-mounted boxIP5443 x electronicout of AUXout of AUX1 AB address
BW2137I/O in surface-mounted boxI/O modulessurface-mounted boxIP5444 x electronicout of AUXout of AUX1 AB address
BW2175I/O in surface-mounted boxI/O modulessurface-mounted boxIP5444 x electronicout of AUXout of AUX1 Single address

 

Passive Distributors ASi, IP67

Figure Type Housing

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

Round cable
Profile cable connection Article No.
BW3186Passive distributor ASidepth: 19 mmIP67yes, depth: 19 mm1 x round cable/connecting wires0,25 m2 x ASi
BW3524Passive distributor ASidepth: 19 mmIP67yes, depth: 19 mm1 x round cable/connecting wires5 m2 x ASi
BW3803Passive distributor ASi/AUXdepth: 28 mmIP67no1 x M12 socket, 5 polesno1 x ASi, 1 x AUX 24 V
BWU3157Passive distributor ASidepth: 19 mmIP67yes, depth: 19 mmprofile cable branchno2 x ASi