Bihl+Wiedemann offers the right module for accessing any safety input signal. Both control cabinet modules (IP20) and field modules (IP67) are available. From a single safety input or output to safety multi-I/O modules we offer the right ASi modul for your requirements. Many of our modules also include available outputs for standard signals.

Bihl+Wiedemann offers the right module for accessing any safety input signal. Both control cabinet modules (IP20) and field modules (IP67) are available. From a single safety input or output to safety multi-I/O modules we offer the right ASi modul for your requirements. Many of our modules also include available outputs for standard signals.
Figure |
Type
|
Inputs Safety, SIL 3, Cat. 4
|
Safety signal inputs
|
Outputs Safety, SIL 3, cat. 4
|
Input voltage (sensor supply)
|
Output voltage (actuator supply)
|
ASi address
|
Special function
|
---|---|---|---|---|---|---|---|---|
IP20, 22,5 mm x 50 mm, 3 x 4 contacts, Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of AUX | 1 Single address | - | |
IP20, 22,5 mm x 50 mm, 3 x 4 contacts, Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of ASi | 1 Single address | - | |
IP20, 22,5 mm x 50 mm, 3 x 4 contacts, Safety | 1 x 2 channels; SIL 2, Cat. 3 | safety mats 1.2 kΩ or 8.2 kΩ monitoring resistor | - | out of AUX | out of AUX | 1 Single address | - | |
IP20, 22,5 mm x 50 mm, 3 x 4 contacts, Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | - | |
IP20, 22,5 mm x 50 mm, 3 x 4 contacts, Safety | 1 x 2 channels | complementary switch | - | out of ASi | out of ASi | 1 Single address | - | |
IP20, 22,5 mm x 114 mm, 4 x 4 contacts, Safety | 1 x 2 channels | floating contacts | - | out of AUX | out of AUX | 1 Single address | - | |
IP20, 22,5 mm x 114 mm, 4 x 4 contacts, Safety | 2 x 2 channels | floating contacts | - | out of AUX | out of AUX | 2 Single addresses | - | |
IP20, 22,5 mm x 114 mm, 4 x 4 contacts, Safety | 2 x 2 channels | floating contacts, complementary OSSDs | - | out of AUX | - | 2 Single addresses | - | |
IP20, 22,5 mm x 114 mm, 4 x 4 contacts, Safety | 2 x 2 channels | floating contacts, OSSDs | - | out of AUX | - | 2 Single addresses | - | |
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, Safety | 1 x 2 channels | 4 ... 20 mA / 0 ... 10 V / Pt100 | - | out of AUX | - | depending on configuration | - | |
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, Safety | 1 x 2 channels | thermocouples | - | out of ASi | - | depending on configuration | - | |
IP67, 8 x M12, ASi-5 Safety | 2 x 2 channels | floating contacts | - | out of AUX | out of AUX | 1 ASi-5 address | - | |
IP67, 8 x M12, ASi-5 Safety | 2 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 ASi-5 address | - | |
IP67, 8 x M12, Safety | 6-8 x 2 channels; depending on configuration | floating contacts, OSSDs, complementary switch | up to 2 release circuits, up to 2 x electronic safe outputs; depending on configuration | out of ASi | out of ASi | depending on configuration | - | |
IP67, 8 x M12, Safety | 6-8 x 2 channels; depending on configuration | floating contacts, OSSDs, complementary switch | up to 2 release circuits, up to 2 x electronic safe outputs; depending on configuration | out of ASi | out of ASi | depending on configuration | - | |
IP67, 8 x M12, Safety | 6-8 x 2 channels; depending on configuration | floating contacts, OSSDs, complementary switch | up to 2 release circuits, up to 2 x electronic safe outputs; depending on configuration | out of AUX | out of AUX | depending on configuration | muting | |
IP67, 8 x M12, Safety | 2 x 2 channels | floating contacts, OSSDs | 4 release circuits, 4 x electronic safe outputs | out of AUX | out of AUX | depending on configuration | - | |
IP67, 4 x M12 (51 mm x 60 mm), Safety | 1 x 2 channels | floating contacts | 1 release circuit, 2 x relay | out of AUX | - | 2 Single addresses + 1 AB address | - | |
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, Safety | - | - | 1-8 release circuits, 8 x electronic safe outputs | out of AUX | out of AUX | depending on configuration | - | |
IP20, 22,5 mm x 114 mm, 4 x 4 contacts, Safety | 1 x 2 channels | floating contacts | 1 release circuit, 2 x relay | out of AUX | - | 2 Single addresses + 1 AB address | - | |
IP20, 22,5 mm x 114 mm, 4 x 4 contacts, Safety | - | - | 1 release circuit, 2 x electronic safe outputs, max. 3 A, augmented reliability | out of AUX | out of AUX | 1 Single address + 2 AB addresses | - | |
IP20, 22,5 mm x 114 mm, 4 x 4 contacts, Safety | - | - | 1 release circuit, 2 x electronic safe outputs | out of AUX | out of AUX | 1 Single address + 2 AB addresses | - | |
IP20, 22,5 mm x 114 mm, 4 x 4 contacts, Safety | - | - | 1 release circuit, 2 x electronic safe outputs, max. 3 A, augmented reliability | out of AUX | out of AUX | 1 Single address + 1 AB address | - | |
IP20, 22,5 mm x 114 mm, 4 x 4 contacts, Safety | - | - | 1 release circuit, 2 x relay | out of ASi | - | 1 Single address + 1 AB address | - | |
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, Safety | - | - | 1 contact expander, 1 x electronic safe output 20 A | - | out of AUX | - | - | |
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, Safety | - | - | 1 contact expander, 1 x electronic safe output 10 A | - | out of AUX | - | - | |
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, Safety | 4 x 2 channels | floating contacts, OSSDs, complementary switch | 2 release circuits, 2 x electronic safe outputs, augmented reliability | out of AUX | out of AUX | depending on configuration, optimised for ASIMON360 | - | |
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, Safety | 8 x 2 channels | floating contacts, OSSDs, complementary switch | 1 release circuit, 1 x electronic safe outputs, augmented reliability | out of AUX | out of AUX | depending on configuration, optimised for ASIMON360 | - | |
IP20, 22,5 mm x 114 mm, 6 x 4 contacts, Safety | 6 x 2 channels | floating contacts, OSSDs, complementary switch | 2 release circuits, 2 x electronic safe outputs, augmented reliability | out of AUX | out of AUX | depending on configuration, optimised for ASIMON360 | - | |
IP67, 4 x M12, Safety | 2 x 2 channels | floating contacts | - | out of ASi | - | 2 Single addresses | - | |
IP67, 4 x M12, Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of AUX | 1 Single address | - | |
IP67, 4 x M12, Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | - | |
IP67, 4 x M12, Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | Reset output for optoelectronic protective devices | |
IP67, 4 x M12, Safety | 1 x 2 channels | complementary switch | - | out of ASi | out of AUX | 1 Single address | - | |
IP67, 4 x M12, Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | - | |
IP67, 4 x M12, Safety | 1 x 2 channels | OSSDs | - | out of ASi | out of ASi | 1 Single address | - | |
IP67, 4 x M12, Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of AUX | 1 Single address | - | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of ASi | 1 Single address | to connect 2 x NC contacts to ASi | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of AUX | 1 Single address | to connect 2 x NC contacts to ASi | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of AUX | 1 Single address | - | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | to connect Leuze MLC530SPG (operation mode 4) to ASi | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | to connect Leuze MLC530SPG (operation mode 5) to ASi | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | To connect Sick deTec4 to ASi | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of ASi | 1 Single address | to connect 2 x NC contacts to ASi | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | - | 1 Single address | to connect 2 x NC contacts to ASi | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | to connect Leuze MLD530-RT3M (operation mode 5) to ASi | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | to connect Leuze MLD530-RT3M to ASi | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of ASi | 1 Single address | to connect 2 x NC contacts to ASi | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of ASi | 1 Single address | to connect 2 x NC contacts to ASi | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | - | 1 Single address | to connect 2 x NC contacts to ASi | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | - | 1 Single address | to connect Sick RE13-SA84 / RE13-SAC / RE23-SAC / RE23-SA84 to ASi | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | - | 1 Single address | to connect E-STOP buttons to ASi via M12 | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | - | 1 Single address | to connect E-STOP buttons to ASi via M12 | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of ASi | 1 Single address | - | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of ASi | 1 Single address | - | |
Active distributor ASi Safety | 1 x 2 channels | floating contacts | - | out of ASi | - | 1 Single address | to connect E-STOP buttons to ASi via M12 | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | - | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | - | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | to connect Euchner MGB / Pizzato ST GD110MP-G1T to ASi | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | - | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | to connect Pilz PSENslock, PSENcode to ASi | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | to connect Pilz PSENslock, PSENcode to ASi | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | to connect Schmersal AZM400 to ASi | |
Active distributor ASi Safety | 1 x 2 channels | OSSDs | - | out of AUX | out of AUX | 1 Single address | to connect Schmersal AZM200 / AZM201 / AZM300 / MZM100 / RSS 16 to ASi | |
circuit board 43 mm x 30 mm, Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of ASi | 1 Single address | for mounting in E-STOP housing | |
circuit board 43 mm x 30 mm, Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of ASi | 1 Single address | for mounting in E-STOP housing | |
circuit board 43 mm x 30 mm, Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of ASi | 1 Single address | for mounting in E-STOP housing | |
circuit board 73 mm x 37,5 mm, Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of AUX | 1 Single address | - | |
circuit board 73 mm x 37,5 mm, Safety | 1 x 2 channels | floating contacts | - | out of ASi | out of AUX | 1 Single address | - | |
circuit board 85 mm x 80 mm, Safety | - | - | 1 release circuit, 1 x electronic safe output | out of AUX | out of AUX | 1 Single address + 2 AB addresses | - |