BWU4001ASi-3 BACnet/IP Gateway with integrated Safety Monitor, 2 ASi masters

Product description

ASi-3 BACnet/IP Gateway with integrated Safety Monitor, 2 ASi masters, OPC UA server, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 128 x 2 channels safe inputs, 3968 x 2 channels safe inputs in max. configuration, 6 release circuits (6 x electronic safe outputs), expandable to max. 128 safe outputs, 3968 safe outputs in max. configuration, Safe Link, diagnostic and configuration via BACnet or Ethernet diagnostic interface, duplicate address recognition, ASi fault detector, programming in C optional, IP20

Technical data

Fieldbus interface

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix fieldbus

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway: interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

BACnet/IP, OPC UA
Safety communication Safe Link
Model Gateway with integrated Safety Monitor
Inputs Safety, SIL 3, Cat. 4 3 x 2 channels
Outputs Safety, SIL 3, cat. 4 6 release circuits, 6 x electronic safe outputs
Number of ASi networks, number of ASi Master
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

2 ASi networks, 2 ASi-3 Masters
Integrated decoupling, ASi current measurement in the gateway

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

no, max. 8 A/ASi network, redundant supply

How to troubleshoot an existing ASi installation

Manuals