Search
![](/fileadmin/_processed_/8/9/csm_3248_with_cable_49978ac221.jpg)
BWU3248 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 1 digital output, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x round cable/connecting wires, cable length 1 m, flat…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/0/c/csm_3249_with_cable_c2afcbf85d.jpg)
BWU3249 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, 1 digital output, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 2 x round cables/connecting wires, cable length 1 m, flat…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/4/8/csm_3250_with_cable_604a4873dc.jpg)
BWU3250 | Active Distributor ASi, IP67, 2I/1O
Active Distributor ASi, IP67, housing depth 19 mm, 2 digital inputs, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 2 x M12 cable sockets, angled, 5 poles, 1 x Y wiring + 1 x mixed wiring, cable length 1 m, flat design,…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
![](/fileadmin/_processed_/2/d/csm_3299_with_cable_13da2dbc33.jpg)
BW3299 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, angled, 5 poles, cable length 1 m, flat design,…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/b/8/csm_3349_9060bdc3c7.jpg)
BWU3349 | Active Distributor ASi, IP20, 4I
Active Distributor ASi, IP20, housing depth 19 mm, 4 digital inputs, input voltage/sensor supply out of AUX, periphery connection via 8 x push in terminals, flat design, installation in cable duct possible (installation depth ≥ 19 mm), LED, connections for 1 x ASi and 1 x AUX profile cables, ASi connection…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
-
View this product in section Passive Distributor
![](/fileadmin/_processed_/b/1/csm_3342_33b9b40a93.jpg)
BWU3342 | Active Distributor ASi, IP20, 4O
Active Distributor ASi, IP20, housing depth 19 mm, 4 digital outputs, output voltage/actuator supply out of AUX, periphery connection via 8 x push in terminals, flat design, installation in cable duct possible (installation depth ≥ 19 mm), LED, connections for 1 x ASi and 1 x AUX profile cables, ASi…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
-
View this product in section Passive Distributor
![](/fileadmin/_processed_/4/3/csm_3300_with_cable_f034656994.jpg)
BW3300 | Active Distributor ASi, IP67, 4O
Active Distributor ASi, IP67, housing depth 19 mm, 4 digital outputs, output voltage/actuator supply out of AUX, periphery connection via 1 x round cable/connecting wires, cable length 1 m, flat design, installation in cable duct possible (installation depth ≥ 19 mm), LED, connections for 1 x ASi and 1 x AUX…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
-
View this product in section Passive Distributor
![](/fileadmin/_processed_/e/d/csm_3413_with_cable_21b390ed1d.jpg)
BWU3413 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x M12 cable socket, angled, 5 poles, cable length 1 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/9/4/csm_3317_with_cable_6041fe7447.jpg)
BWU3317 | Active Distributor ASi, IP67, 4I/4O
Active Distributor ASi, IP67, housing depth 35 mm, 4 digital inputs, 4 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of AUX, periphery connection via 2 x round cables/connecting wires, cable length 1 m, flat design, installation in cable duct possible…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
-
View this product in section Passive Distributor
![](/fileadmin/_processed_/b/7/csm_3326_with_cable_63ec44484f.jpg)
BWU3326 | Active Distributor ASi, IP67, 4I/4O
Active Distributor ASi, IP67, housing depth 35 mm, 4 digital inputs, 4 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 2 x round cables/connecting wires, cable length 1 m, flat design, installation in cable duct possible…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
-
View this product in section Passive Distributor
![](/fileadmin/_processed_/3/f/csm_3400_with_cable_e9bd325dfe.jpg)
BWU3400 | Active Distributor ASi, IP67, 2I/2O
Active Distributor ASi, IP67, housing depth 19 mm, 2 digital inputs, 2 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x M12 cable socket, straight, 8 poles, cable length 1 m, flat design, installation in cable duct possible…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
![](/fileadmin/_processed_/4/1/csm_3414_cede9eac7f.jpg)
BWU3414 | Active Distributor ASi, IP20, 3I/1O
Active Distributor ASi, IP20, housing depth 19 mm, 3 digital inputs, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 8 x push in terminals, flat design, installation in cable duct possible (installation depth ≥ 19 mm), LED,…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
-
View this product in section Passive Distributor
![](/fileadmin/_processed_/a/2/csm_3376_with_cable_61be6e4f20.jpg)
BWU3376 | Active Distributor ASi Safety, IP67, 1SI/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 5 poles, cable length 1 m, flat design,…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/5/b/csm_3377_with_cable_9abe2a86ad.jpg)
BW3377 | Active Distributor ASi, IP67, 4I/4O
Active Distributor ASi, IP67, housing depth 35 mm, 4 digital inputs, 4 digital outputs, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 8 poles, cable length 1 m, flat design, installation in cable duct possible…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
![](/fileadmin/_processed_/2/3/csm_3507_with_cable_6c9d1ed9b5.jpg)
BW3507 | Active Distributor ASi, IP67, 4I/4O
Active Distributor ASi, IP67, housing depth 35 mm, 4 digital inputs, 4 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of AUX, periphery connection via 2 x M12 cable sockets, straight, 5 poles, cable length 1 m, flat design, installation in cable duct possible…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
![](/fileadmin/_processed_/7/2/csm_3553_with_cable_dd565db046.jpg)
BWU3553 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x M8cable socket, straight, 4 poles, cable length 0,20 m, flat design, installation in cable duct possible…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/f/8/csm_3500_with_cable_7e4bc87428.jpg)
BW3500 | Active Distributor ASi, IP67, 4I/4O
Active Distributor ASi, IP67, housing depth 35 mm, 4 digital inputs, 4 digital outputs, input voltage/sensor supply out of ASi, output voltage/actuator supply out of ASi, periphery connection via 1 x round cable/connecting wires, cable length 5 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
![](/fileadmin/_processed_/8/a/csm_3497_with_cable_8748227b5f.jpg)
BWU3497 | Active Distributor ASi, IP67, 2I/2O
Active Distributor ASi, IP67, housing depth 19 mm, 2 digital inputs, 2 digital outputs, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 2 x M12 cable sockets, straight, 5 poles, Y wiring, cable length 0,4 m, flat design, installation in cable duct…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
![](/fileadmin/_processed_/c/a/csm_3498_with_cable_5747bf81c7.jpg)
BWU3498 | Active Distributor ASi, IP67, 4I
Active Distributor ASi, IP67, housing depth 19 mm, 4 digital inputs, input voltage/sensor supply out of AUX, periphery connection via 2 x M12 cable sockets, straight, 5 poles, Y wiring, cable length 0,4 m, flat design, installation in cable duct possible (installation depth ≥ 19 mm), LED, connections for 1 x …
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
![](/fileadmin/_processed_/3/b/csm_3564_with_cable_1fbd1a4d9a.jpg)
BWU3564 | Active Distributor ASi, IP67, 2I
Active Distributor ASi, IP67, housing depth 19 mm, 2 digital inputs, input voltage/sensor supply out of AUX, periphery connection via 1 x M12 cable socket, angled, 5 poles, Y wiring, cable length 1 m, flat design, installation in cable duct possible (installation depth ≥ 19 mm), LED, connections for 1 x ASi…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
![](/fileadmin/_processed_/5/1/csm_3488_939599c984.jpg)
BWU3488 | Active Distributor ASi Safety, IP67, 1SI/1I/1O
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for OSSDs, 1 digital input, 1 digital output, input voltage/sensor supply out of AUX, output voltage/actuator supply out of AUX, periphery connection via 1 x M12 cable socket, straight, 8 poles, cable length 1…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/9/c/csm_3487_993ce54a97.jpg)
BWU3487 | Active Distributor ASi, IP67, 4O
Active Distributor ASi, IP67, housing depth 19 mm, 4 digital outputs, output voltage/actuator supply out of AUX, periphery connection via 1 x round cable/connecting wires, cable length 5 m, flat design, installation in cable duct possible (installation depth ≥ 19 mm), LED, connections for 1 x ASi and 1 x AUX…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
![](/fileadmin/_processed_/8/c/csm_3373_with_cable_4d2011a41b.jpg)
BWU3373 | Active Distributor ASi Safety, IP67, 1SI
Active Distributor ASi Safety, IP67, housing depth 19 mm, 1 x 2 channels safe input (SIL 3, cat. 4) for floating contacts, input voltage/sensor supply out of ASi, periphery connection via 1 x round cable/connecting wires, cable length 0,3 m, flat design, installation in cable duct possible (installation…
-
View this product in section Active Distributors ASi Safety
-
View this product in section Safety I/O Modules
![](/fileadmin/_processed_/7/e/csm_3374_with_cable_118786076b.jpg)
BWU3374 | Active Distributor ASi, IP67, 4I
Active Distributor ASi, IP67, housing depth 35 mm, 4 digital inputs, input voltage/sensor supply out of ASi, periphery connection via 2 x round cables/connecting wires, cable length 0,5 m, flat design, installation in cable duct possible (installation depth ≥ 35 mm), LED, connection for 1 x ASi profile cable,…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules
![](/fileadmin/_processed_/2/9/csm_3555_with_cable_96ba25acef.jpg)
BWU3555 | Active Distributor ASi, IP67, 4I/4O
Active Distributor ASi, IP67, housing depth 35 mm, 4 digital inputs, 4 digital outputs, Y wiring, input voltage/sensor supply out of ASi, output voltage/actuator supply out of AUX, periphery connection via 4 x M8 cable sockets, straight, 4 poles, cable length 0,2 m, flat design, installation in cable duct…
-
View this product in section Active Distributors ASi
-
View this product in section I/O Modules