EtherNet/IP + Modbus/TCP Fieldbus system

What is EtherNet/IP?
EtherNet/IP (Ethernet Industrial Protocol) is an open, CIP-based fieldbus standard developed by Rockwell Automation and the ODVA (Open DeviceNet Vendor Association) which is used mainly in automation technology. EtherNet/IP enables communication between devices made by different manufacturers without any special interface adaptations.
What is Modbus/TCP?
Modbus TCP/IP is an open fieldbus standard for industrial communication using ethernet. It is used mainly in automation technology and enables communication between devices from different manufacturers without any special interface adaptations.
EtherNet/IP + Modbus/TCP Products
EtherNet/IP + Modbus/TCP ASi Gateways
EtherNet/IP + Modbus/TCP ASi Gateways in stainless steel provide an interface for an EtherNet/IP + Modbus/TCP fieldbus. These ASi gateways are available in various versions with IP20 protection rating.EtherNet/IP + Modbus/TCP ASi
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|
![]() | EtherNet/IP + ModbusTCP ASi | Gateway | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus | yes | yes | optional | BWU3736 ASi-3 EtherNet/IP+ModbusTCP Gateway in Stainless Steel, 2 masters |
![]() | EtherNet/IP + ModbusTCP ASi | Gateway | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-3 Masters | no, max. 8 A/ASi network, redundant supply | Ethernet fieldbus | yes | yes | optional | BWU3735 ASi-3 EtherNet/IP+ModbusTCP Gateway in Stainless Steel, 2 masters |
![]() | EtherNet/IP + ModbusTCP ASi | Gateway | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 1 ASi network, 1 ASi-3 Master | no, max. 8 A/ASi network | Ethernet fieldbus | yes | yes | optional | BWU3734 ASi-3 EtherNet/IP+ModbusTCP Gateway in Stainless Steel, 1 master |
![]() | 24 Volt ASi Gateway | Gateway | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 1 ASi network, 1 ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus | yes | yes | no | BWU3822 24 Volt ASi-3 EtherNet/IP + Modbus TCP Gateway in Stainless Steel, 1 ASi-3 master |
![]() | EtherNet/IP + Modbus TCP ASi-5/ASi-3 | Gateway | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3851 ASi-5/ASi-3 EtherNet/IP+ModbusTCP Gateway in Stainless Steel, 2 ASi-5/ASi-3 masters |
![]() | EtherNet/IP + Modbus TCP ASi-5/ASi-3 | Gateway | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 8 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU4258 ASi-5/ASi-3 EtherNet/IP + Modbus TCP Gateway in Stainless Steel, 2 ASi-5/ASi-3 masters |
![]() | EtherNet/IP + Modbus TCP ASi-5/ASi-3 | Gateway | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 8 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU4019 ASi-5/ASi-3 EtherNet/IP + Modbus TCP Gateway in Stainless Steel, 1 ASi-5/ASi-3 master |
![]() | 24 Volt ASi-5/ASi-3 Gateway | Gateway | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus | yes | yes | no | BWU3849 24 Volt ASi-5/ASi-3 EtherNet/IP + Modbus TCP Gateway in Stainless Steel, 1 ASi-5/ASi-3 master |
![]() | Starter Kits ASi-5/IO-Link | Starter Kits | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus | yes | yes | - | BW4229 Small Starter Kit ASi-5/IO-Link via EtherNet/IP |
Safety, EtherNet/IP + Modbus/TCP ASi
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix fieldbus POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. Safety devices "Single Master" : 1 ASi network, 1 ASi-5/ASi-3 Master. 1 ASi network, 1 ASi-3 Master. 2 ASi networks, 2 ASi-5/ASi-3 Masters. 2 ASi networks, 2 ASi-3 Masters. | " yes, max. 4 A/ASi network ": Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply). Operation with short cable lengths with standard 24 V power supply possible.
Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies. Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.
1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.
The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi nodes. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | An externally connected relay (contactor) can be monitored by connecting the feedback loop to the EDM input. | Inputs Safety, SIL 3, Cat. 4 | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Safety, EtherNet/IP + ModbusTCP | Gateway with integrated Safety Monitor | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | CIP Safety over EtherNet/IP + Safe Link | BWU3683 ASi-3 CIP Safety over EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi masters |
![]() | Safety, EtherNet/IP + ModbusTCP | Gateway with integrated Safety Monitor | IP20 | EtherNet/IP + ModbusTCP | 2 ASi networks, 2 ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 32, max. 992 in max. configuration | Safe Link | BWU3543 ASi-3 EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi masters |
![]() | Safety, EtherNet/IP + ModbusTCP | Gateway with integrated Safety Monitor | IP20 | EtherNet/IP + ModbusTCP | 2 ASi networks, 2 ASi-3 Masters | no, max. 8 A/ASi network, redundant supply | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 32, max. 992 in max. configuration | Safe Link | BWU3544 ASi-3 EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi masters |
![]() | Safety, EtherNet/IP + ModbusTCP | Gateway with integrated Safety Monitor | IP20 | EtherNet/IP + ModbusTCP | 1 ASi network, 1 ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | BWU3542 ASi-3 EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 1 ASi master |
![]() | Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | CIP Safety over EtherNet/IP + Safe Link | BWU3857 ASi-5/ASi-3 CIP Safety over EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() | Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | Safe Link | BWU3825 ASi-5/ASi-3 EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() | Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | EtherNet/IP + ModbusTCP, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | BWU3866 ASi-5/ASi-3 EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
GE Digital Achilles® Robustness Test (Level 1 and 2, Version No. 3.18)
Ethernet fieldbus interface (PROFINET, EtherNet/IP) and Ethernet diagnostic interface of the ASi-5/ASi-3 gateways are submitted to strict robustness testing via the Achilles Test Software to ensure robustness against vulnerabilities to cyber attacks. The field update capabilities of the gateway enable continuous firmware and security updates to continuously improve the functionality and robustness of the device.