Bihl+Wiedemann offers the right module for accessing any safety input signal. Both control cabinet modules (IP20) and field modules (IP67) are available. From a single safety input or output to safety multi-I/O modules we offer the right ASi modul for your requirements. Many of our modules also include available outputs for standard signals.
Bihl+Wiedemann offers the right module for accessing any safety input signal. Both control cabinet modules (IP20) and field modules (IP67) are available. From a single safety input or output to safety multi-I/O modules we offer the right ASi modul for your requirements. Many of our modules also include available outputs for standard signals.
Figure |
Inputs Safety
|
Safety signal inputs
|
Outputs Safety
|
Safety signal outputs
|
Input voltage (sensor supply)
|
Output voltage (actuator supply)
|
ASi address
|
Special function
| |
---|---|---|---|---|---|---|---|---|---|
2 x 2 channels, 4 x 1 channel
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 ASi-5 address
|
no special function
| ||
2 x 2 channels, 4 x 1 channel
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 ASi-5 address
|
no special function
| ||
2 x 2 channels, 4 x 1 channel
|
OSSDs, floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 ASi-5 address
|
no special function
| ||
1 x 2 channels + 2 x 1 channel, 4 x 1 channel
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 ASi-5 address
|
muting
| ||
2 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
no output voltage
|
2 Single addresses
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
Reset output for optoelectronic protective devices
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
complementary switch
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of AUX
|
1 Single address
|
no special function
| ||
6-8 x 2 channels; depending on configuration
|
OSSDs, complementary switch, floating contacts
|
up to 2 release circuits, up to 2 x electronic safe outputs; depending on configuration
|
electronic safe outputs
|
out of ASi
|
out of ASi
|
depending on configuration
|
no special function
| ||
6-8 x 2 channels; depending on configuration
|
OSSDs, complementary switch, floating contacts
|
up to 2 release circuits, up to 2 x electronic safe outputs; depending on configuration
|
electronic safe outputs
|
out of ASi
|
out of ASi
|
depending on configuration
|
no special function
| ||
6-8 x 2 channels; depending on configuration
|
OSSDs, complementary switch, floating contacts
|
up to 2 release circuits, up to 2 x electronic safe outputs; depending on configuration
|
electronic safe outputs
|
out of AUX
|
out of AUX
|
depending on configuration
|
muting
| ||
2 x 2 channels
|
OSSDs, floating contacts
|
4 release circuits, 4 x electronic safe outputs
|
electronic safe outputs
|
out of AUX
|
out of AUX
|
depending on configuration
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
1 release circuit, 2 x relay
|
relay outputs
|
out of AUX
|
out of ASi
|
1 AB address, 2 Single addresses
|
safety-switched AUX branches via M12, secure data exchange
| ||
1 x 2 channels
|
floating contacts
|
1 release circuit, 2 x relay
|
relay outputs
|
out of AUX
|
out of ASi
|
1 AB address, 2 Single addresses
|
safety-switched AUX branches via profile cable, secure data exchange
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
-
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
-
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of AUX
|
1 Single address
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
no output voltage
|
1 Single address
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
no output voltage
|
1 Single address
|
to connect E-STOP buttons to ASi via M12
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
no output voltage
|
1 Single address
|
to connect 2 x NC contacts to ASi
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
no output voltage
|
1 Single address
|
to connect Sick RE13-SA84 / RE13-SAC / RE23-SAC / RE23-SA84 to ASi
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
no output voltage
|
1 Single address
|
to connect E-STOP buttons to ASi via M12
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
no output voltage
|
1 Single address
|
to connect E-STOP buttons to ASi via M12
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect Pilz PSENslock, PSENcode to ASi
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect Pilz PSENslock, PSENcode to ASi
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect Schmersal AZM400 to ASi
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect Schmersal AZM200 / AZM201 / AZM300 / MZM100 / RSS 16 to ASi
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect Keyence GS-71PC / GS-11PC / GS-M51P / GS-ML51P / GS-M91P to ASi
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect Leuze MLC530R-SPG + Leuze MLC500T-SPG (operation mode 5) to ASi
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect Leuze MLD530-RT3M (operation mode 5) to ASi
| ||
1 x 2 channels
|
OSSDs
|
-
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect Leuze MLD530-RT3M to ASi
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect Euchner MGB / Pizzato ST GD110MP-G1T to ASi
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect Leuze MLC530R + Leuze MLC500T (operation mode 4) to ASi
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
To connect Sick deTec4 to ASi
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
to connect door contact switch Keyence GS-10PC Series
| ||
2 x 2 channels, 4 x 1 channel
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 ASi-5 address
|
no special function
| ||
2 x 2 channels, 4 x 1 channel
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 ASi-5 address
|
no special function
| ||
2 x 2 channels, 4 x 1 channel
|
OSSDs, floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 ASi-5 address
|
no special function
| ||
8 x 2 channels
|
OSSDs, complementary OSSDs, complementary switch, floating contacts
|
1 release circuit, 1 x electronic safe outputs, augmented reliability
|
electronic safe outputs
|
out of AUX
|
out of AUX
|
depending on configuration, optimised for ASIMON360
|
no special function
| ||
6 x 2 channels
|
OSSDs, complementary switch, floating contacts
|
2 release circuits, 2 x electronic safe outputs, augmented reliability
|
electronic safe outputs
|
out of AUX
|
out of AUX
|
depending on configuration, optimised for ASIMON360
|
no special function
| ||
4 x 2 channels
|
OSSDs, complementary OSSDs, complementary switch, floating contacts
|
2 release circuits, 2 x electronic safe outputs, augmented reliability
|
electronic safe outputs
|
out of AUX
|
out of AUX
|
depending on configuration, optimised for ASIMON360
|
no special function
| ||
1 x 2 channels
|
4 ... 20 mA / 0 ... 10 V / Pt100
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
no output voltage
|
depending on configuration
|
no special function
| ||
1 x 2 channels
|
thermocouples
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
no output voltage
|
depending on configuration
|
no special function
| ||
no local safe inputs
|
no Safety signal inputs
|
1-8 release circuits, 8 x electronic safe outputs
|
electronic safe outputs
|
out of AUX
|
out of AUX
|
depending on configuration
|
no special function
| ||
2 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
2 Single addresses
|
no special function
| ||
2 x 2 channels
|
OSSDs, floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
no output voltage
|
2 Single addresses
|
no special function
| ||
2 x 2 channels
|
complementary OSSDs, floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
no output voltage
|
2 Single addresses
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
1 release circuit, 2 x relay
|
relay outputs
|
out of AUX
|
no output voltage
|
1 AB address, 2 Single addresses
|
no special function
| ||
no local safe inputs
|
no Safety signal inputs
|
1 release circuit, 2 x electronic safe outputs, max. 3 A, augmented reliability
|
electronic safe outputs
|
out of AUX
|
out of AUX
|
1 Single address, 2 AB addresses
|
no special function
| ||
no local safe inputs
|
no Safety signal inputs
|
1 release circuit, 2 x electronic safe outputs
|
electronic safe outputs
|
out of AUX
|
out of AUX
|
1 Single address, 2 AB addresses
|
no special function
| ||
no local safe inputs
|
no Safety signal inputs
|
1 release circuit, 2 x electronic safe outputs, max. 3 A, augmented reliability
|
electronic safe outputs
|
out of AUX
|
out of AUX
|
1 AB address, 1 Single address
|
no special function
| ||
no local safe inputs
|
no Safety signal inputs
|
1 release circuit, 2 x relay
|
relay outputs
|
out of ASi
|
no output voltage
|
1 AB address, 1 Single address
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
OSSDs
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
complementary switch
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
no special function
| ||
1 x 2 channels; SIL 2, Cat. 3
|
safety mats 1.2 kΩ or 8.2 kΩ monitoring resistor
|
no local safe output
|
no Safety signal outputs
|
out of AUX
|
out of AUX
|
1 Single address
|
no special function
| ||
no local safe inputs
|
no Safety signal inputs
|
1 contact expander, 1 x electronic safe output 20 A
|
electronic safe outputs
|
no input voltage
|
out of AUX
|
-
|
no special function
| ||
no local safe inputs
|
no Safety signal inputs
|
1 contact expander, 1 x electronic safe output 10 A
|
electronic safe outputs
|
no input voltage
|
out of AUX
|
-
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
for mounting in E-STOP housing
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
for mounting in E-STOP housing
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of ASi
|
1 Single address
|
for mounting in E-STOP housing
| ||
1 x 2 channels
|
floating contacts
|
no local safe output
|
no Safety signal outputs
|
out of ASi
|
out of AUX
|
1 Single address
|
no special function
| ||
1 x 2 channels
|
floating contacts
|
-
|
-
|
out of ASi
|
out of AUX
|
1 Single address
|
-
| ||
1 x 2 channels
|
floating contacts
|
-
|
no Safety signal outputs
|
out of ASi
|
out of AUX
|
1 Single address
|
no special function
| ||
no local safe inputs
|
no Safety signal inputs
|
1 release circuit, 1 x electronic safe output
|
electronic safe outputs
|
out of AUX
|
out of AUX
|
1 Single address, 2 AB addresses
|